Catalog excerpts
^^^^^ ^^fl^^ ^tf^^ INPUT / OUTPUT / POWER SUPPLY / COMMUNICATION modules
Open the catalog to page 1analogue flowmeters pulse flow or ratemeters 8 8 Output modules current
Open the catalog to page 2Controllers, data recorders, HMI The MultiCon series includes advanced controllers and data recorders with great potential closed in small casings. MultiCon CMC has been specifically designed for advanced applications in industrial automatic control engineering. It does not mean, however, that the device cannot be applied in smaller systems. MultiCon CMC can be equipped with three isolated RS-485 interfaces which make it a perfect solution for distributed systems to work as CPU. Thanks to Ethernet interface the device can be monitored via the Internet. A wide range of input and output...
Open the catalog to page 3Ordering MultiCon CMC-XX-P/D/C/B/A-XX1 version: 99 : 96 x 96 mm case 141 : 144 x 144 mm case slot P - power supply module slot D - communication module options: 00: no options 01: IP 65 frame 08: operating temp. -20°C ÷ +50°C 0B: front USB Host (IP 40) 0P: IP 65 + operating temp. -20°C ÷ +50°C 0K: front USB Host + operating temp. -20°C ÷ +50°C available modules listed below Optional: LKS-99/141 Data logging licence key or MLS-99/141 MultiLevel Access licence key Module type power supply 85 ÷ 260V AC/DC no communication module (available for 0B option only) communication module (1 x USB...
Open the catalog to page 4Power supply modules PS32: 19V ÷ 50V DC; 16V ÷ 35V AC PS42: 85V ÷ 260V DC or AC PS32 and PS42 modules are used to supply the MultiCon. PS32 module can be supplied with: 19V ÷ 50V DC 16V ÷ 35V AC PS42 module can be supplied with: 85V ÷ 260V DC or AC Additionally modules contain: - service purpose input (service port), - 24V DC output, used to supply external sensors, - digital input, used for digital signal measurement, - RS-485 port, used for communication with other devices using Modbus protocol. Power supply 85V÷260V AC/DC GND +24V DC ±5% Imax. = 200mA digital input 0/15..24V DC GND +24V...
Open the catalog to page 5Input modules - universal UN3: 3 isolated universal inputs UN5: 5 isolated universal inputs On customer's request, it is possible to install modules equipped with 3 or 5 universal inputs. Each module includes a sensor for cold junction compensation. It is most advanced input module, available for the CMC. With its help user can make many different kind of measurements in each channel. This module can measure: voltage, current, resistance, temperature using resistance sensors or thermocouples. Pin description: IN_T : Cold Junction temperature sensor TECHNICAL DATA UN3 Number of inputs...
Open the catalog to page 6Input modules - current I16: 16 current inputs I24: 24 current inputs IS6: 6 isolated current inputs MultiCon can be equipped with modules having 16 or 24 non isolated or 6 isolated current inputs. To make sensor connection easier, modules I16 and I24 have inputs groupped into fours. IS6 module has all inputs separated one from another and signal polarity on it's inputs has no matter. 2 Power supply (depending on version) Examplary connection for 2 - wire sensors and IS6 module IS6 6 isolated current inputs IS6 6 isolated current inputs Current inputs parameters are: - Name - read-only...
Open the catalog to page 7Input modules - voltage U16: 16 voltage inputs U24: 24 voltage inputs On customer's request, the MultiCon device can be equipped with 16 or 24 voltage input modules. To make sensor connection easier, inputs are grouped and all ground terminals are common but separated from power supply and other modules. Measurement range Hardware limitation Hardware resolution Temperature stability Internal impedance Sampling period 10 ms (CMC reads modules every 100 ms) 10 ms (CMC reads modules every 100 ms) Power supply Connections for 3 - wire sensor (voltage) Voltage input parameters are: - Name -...
Open the catalog to page 8Input modules - voltage/current UI4: 4 voltage + 4 current inputs UI8: 8 voltage + 8 current inputs UI12: 12 voltage + 12 current inputs The MultiCon UI modules include 8, 16 or 24 voltage / current inputs, mixed where half of them are voltage and half are current. To make sensor connection easier, inputs are grouped and all ground terminals are common but separated from power supply and other modules. UI8 4 current + 4 voltage inputs 2 Power supply (depending on version) 4 current + 4 voltage inputs Connections for 3 - wire sensor (voltage) Connections for 3 - wire sensor (current) Voltage...
Open the catalog to page 9Input modules - voltage/current/NTC UI4N8: 4 voltage + 4 current + 8 NTC inputs UI8N8: 8 voltage + 8 current + 8 NTC inputs The MultiCon UIN modules include 16 or 24 voltage / current / NTC inputs, which allows to measure current, voltage, resistance and temperature (using NTC sensors). Inputs are gathered into groups to make connections easier. All ground terminals of a particular module are common, but separated from power supply and other modules. If it is necessary to make measurements with different ground potentials, several UIN modules have to be installed into MultiCon unit. When...
Open the catalog to page 10Input modules - voltage/current/digital UI4D8: 4 voltage + 4 current + 8 digital inputs UI8D8: 8 voltage + 8 current + 8 digital inputs The MultiCon UID modules include 16 or 24 voltage / current / digital inputs, which allows to measure current and voltage and can be equipped with uninsulated digital inputs. Inputs are gathered into groups to make connections easier. All ground terminals of a particular module are common, but separated from power supply and other modules. If it is necessary to make measurements with different ground potentials, several UID modules have to be installed into...
Open the catalog to page 11Input modules - thermocouple TC4: 4 thermocouple inputs TC8: 8 thermocouple inputs TC12: 12 thermocouple inputs The range of TC modules consist of 4, 8 and 12 thermocouple input modules, each equipped with 1 input for connectors temperature measurement. Primary destination of these modules is temperature measurement using thermocouple sensors, but it is also possible to measure voltage with typical thermocouple ranges. TC modules parameters are: - Name - read-only input name given by the device, - Unit - read-only field which displays „°C” or „mV”, depending on Mode parameter settings, -...
Open the catalog to page 12All SIMEX Sp. z o.o. catalogs and technical brochures
-
Temperature sensors catalogue
96 Pages
-
STH-42
2 Pages
-
SPP-638
3 Pages
-
SLC_30_46_47
2 Pages
-
SLN-44
2 Pages
-
SLE-42
2 Pages
-
SWZ-W610
3 Pages
-
SPP-N118
3 Pages
-
SPP-94
3 Pages
-
SPI-638
3 Pages
-
SPI-N118
3 Pages
-
SPI-94
3 Pages
-
STI-638
3 Pages
-
STI-N118
3 Pages
-
STI-94
3 Pages
-
STI-73
3 Pages
-
SLN-94
3 Pages
-
SLK-94T
3 Pages
-
SLIK-638
3 Pages
-
SLIK-N118_eng.pdf
3 Pages
-
SLB-94
3 Pages
-
SLIK-94
3 Pages
-
SLIK-73
3 Pages
-
SLE-73
3 Pages
-
SLC-457
3 Pages
-
SLC-94
3 Pages
-
MultiCon
19 Pages
-
SCK-11
1 Pages
-
SimCorder Soft Overview
7 Pages
-
Galvanic Isolators brochure
4 Pages
-
Digital indicator SWS-147
3 Pages
Archived catalogs
-
MultiCon Overview
19 Pages
-
SWS-99
1 Pages
-
Product Overview BROGOEN
32 Pages
-
MultiCon overview BRCMCEN
19 Pages
-
Product Overview
33 Pages
-
BROGOEN_v1.15.071
28 Pages
-
MultiCon brochure
13 Pages
-
SIMEX Product Overview 2014
28 Pages
-
MultiCon brochure
11 Pages
-
SIMEX Catalogue
78 Pages