Sensors, transmitters, separators SGS-61 galvanic separator full galvanic isolation of 4-20 mA correction of characteristic thin DIN rail housing - 6,1 mm only Separator SGS-61 allows to input full galvanic isolation between transmitter and receiver of 4-20 mA current loop. Additionally it enables a possibility of connecting more than one receiver (e.g. two meters) with common ground in series in one current loop. Thanks to powering directly from current loop the device does not require any additional power supply, and full galvanic isolation allows using it in many applications with high requirements. Potentiometers which are available from the front, allow to trim minimum current and slope of characteristic, so the correction of whole current loop is possible. The device was built into a very thin housing (6,1 mm) designed for DIN rail mounting, what gives a possibility of its easy application in existing and being assembled systems. - powered directly from current loop, - trim minimum current and slope of characteristic, - very thin DIN housing - 6,1 mm only. Calibration The correction of system transmittance is realised via potentiometers P1, P2, available from the front after removing of small cap. P1 - regulation of 4,00 mA (@ IIN = 4,00 mA, min. current) P2 - regulation of 20,00 mA (@ IIN = 20,00 mA, slope) P1 P2 Technical data Input loop: Current: 4 ÷ 20 mA; IIN MIN = 3,9 mA; IIN MAX = 24 mA Voltage drop: max. 5,5 V Input side powered directly from input current loop Output loop: Current: 4 ÷ 20 mA; IOUT MIN = 3,9 mA; IOUT MAX = 24 mA Powering of output loop: 9 ÷ 30 V DC (any polarisation connected to OUT1, OUT2 ) Max load resistance: max. 1 kW (for 30 V / IOUT = 20 mA supply) After regulation it is recommended to check circuit characteristic for both 4 mA and 20 mA. Warning: proper sequence is necessary while circuit calibration. First potentiometer P1, next P2. Another data: Transmittance factor: KI = IOUT / IIN = 1 Bandwith: 200 Hz (3 dB) Separation: between input and output loops Insulation voltage: 750 V Temperature stability: 100 ppm / °C Operating temperature: 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) Storage temperature: -10°C ÷ +70°C (standard), -20°C ÷ +70°C (with option 08) Protection level: IP 20 Housing type: DIN rail mounted (35 mm rail) Housing dimensions: 80 x 6,1 x 93,8 mm Weight: 35 g Ordering SGS-61-1115-0-1-XX1 options: 00 : no options 08 : operating temp. -20°C ÷ +50°C V.13.01.1 80-556 Gdańsk, Wielopole 7, POLAND, tel. (+48 58) 762-07-77, fax 762-07-70, www.simex.pl, e-mail: info@sim
Open the catalog to page 1All SIMEX Sp. z o.o. catalogs and technical brochures
-
Temperature sensors catalogue
96 Pages
-
STH-42
2 Pages
-
SPP-638
3 Pages
-
SLC_30_46_47
2 Pages
-
SLN-44
2 Pages
-
SLE-42
2 Pages
-
SWZ-W610
3 Pages
-
SPP-N118
3 Pages
-
SPP-94
3 Pages
-
SPI-638
3 Pages
-
SPI-N118
3 Pages
-
SPI-94
3 Pages
-
STI-638
3 Pages
-
STI-N118
3 Pages
-
STI-94
3 Pages
-
STI-73
3 Pages
-
SLN-94
3 Pages
-
SLK-94T
3 Pages
-
SLIK-638
3 Pages
-
SLIK-N118_eng.pdf
3 Pages
-
SLB-94
3 Pages
-
SLIK-94
3 Pages
-
SLIK-73
3 Pages
-
SLE-73
3 Pages
-
SLC-457
3 Pages
-
SLC-94
3 Pages
-
MultiCon
19 Pages
-
SCK-11
1 Pages
-
SimCorder Soft Overview
7 Pages
-
Galvanic Isolators brochure
4 Pages
-
Digital indicator SWS-147
3 Pages
Archived catalogs
-
MultiCon Overview
19 Pages
-
SWS-99
1 Pages
-
Product Overview BROGOEN
32 Pages
-
MultiCon overview BRCMCEN
19 Pages
-
Product Overview
33 Pages
-
BROGOEN_v1.15.071
28 Pages
-
MultiCon brochure
13 Pages
-
SIMEX Product Overview 2014
28 Pages
-
MultiCon brochure
11 Pages
-
SIMEX Catalogue
78 Pages