Specifications:
  • Input Loop: Current range is 4 to 20 mA with a minimum of 3.9 mA and a maximum of 24 mA. The voltage drop is a maximum of 5.5 V. The input side is powered directly from the input current loop.
  • Output Loop: Current range is 4 to 20 mA with a minimum of 3.9 mA and a maximum of 24 mA. The output loop is powered by 9 to 30 V DC, with any polarization connected to OUT1, OUT2. Maximum load resistance is 1 kΩ for a 30 V / 20 mA supply.
  • Other Data: Transmittance factor is 1. Bandwidth is 200 Hz (3 dB). Separation exists between input and output loops with an insulation voltage of 750 V. Temperature stability is 100 ppm/°C. Protection level is IP 20. Housing type is DIN rail mounted (35 mm rail) with dimensions of 80 x 6.1 x 93.8 mm and a weight of 35 g. Operating temperature is 0°C to +50°C, with storage temperature options.
Technical Data:
  • The SGS-61 provides full galvanic isolation of the 4-20 mA current loop, allowing connection of multiple receivers with a common ground in series. It is powered directly from the current loop, requiring no additional power supply. Potentiometers allow trimming of minimum current and slope for correction of the current loop.
Applications:
  • Typical applications include systems requiring galvanic isolation and correction of current loop characteristics.
Calibration:
  • Calibration is performed using potentiometers P1 and P2, accessible from the front. P1 adjusts the 4.00 mA minimum current, and P2 adjusts the 20.00 mA slope. Proper sequence is necessary: first P1, then P2.
Ordering Information:
  • Options include no options (00) or an operating temperature range of -20°C to +50°C (08).
See more

Catalog excerpts

Galvanic separator SGS-61 datasheet-1

Sensors, transmitters, separators SGS-61 galvanic separator full galvanic isolation of 4-20 mA correction of characteristic thin DIN rail housing - 6,1 mm only Separator SGS-61 allows to input full galvanic isolation between transmitter and receiver of 4-20 mA current loop. Additionally it enables a possibility of connecting more than one receiver (e.g. two meters) with common ground in series in one current loop. Thanks to powering directly from current loop the device does not require any additional power supply, and full galvanic isolation allows using it in many applications with high requirements. Potentiometers which are available from the front, allow to trim minimum current and slope of characteristic, so the correction of whole current loop is possible. The device was built into a very thin housing (6,1 mm) designed for DIN rail mounting, what gives a possibility of its easy application in existing and being assembled systems. - powered directly from current loop, - trim minimum current and slope of characteristic, - very thin DIN housing - 6,1 mm only. Calibration The correction of system transmittance is realised via potentiometers P1, P2, available from the front after removing of small cap. P1 - regulation of 4,00 mA (@ IIN = 4,00 mA, min. current) P2 - regulation of 20,00 mA (@ IIN = 20,00 mA, slope) P1 P2 Technical data Input loop: Current: 4 ÷ 20 mA; IIN MIN = 3,9 mA; IIN MAX = 24 mA Voltage drop: max. 5,5 V Input side powered directly from input current loop Output loop: Current: 4 ÷ 20 mA; IOUT MIN = 3,9 mA; IOUT MAX = 24 mA Powering of output loop: 9 ÷ 30 V DC (any polarisation connected to OUT1, OUT2 ) Max load resistance: max. 1 kW (for 30 V / IOUT = 20 mA supply) After regulation it is recommended to check circuit characteristic for both 4 mA and 20 mA. Warning: proper sequence is necessary while circuit calibration. First potentiometer P1, next P2. Another data: Transmittance factor: KI = IOUT / IIN = 1 Bandwith: 200 Hz (3 dB) Separation: between input and output loops Insulation voltage: 750 V Temperature stability: 100 ppm / °C Operating temperature: 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) Storage temperature: -10°C ÷ +70°C (standard), -20°C ÷ +70°C (with option 08) Protection level: IP 20 Housing type: DIN rail mounted (35 mm rail) Housing dimensions: 80 x 6,1 x 93,8 mm Weight: 35 g Ordering SGS-61-1115-0-1-XX1 options: 00 : no options 08 : operating temp. -20°C ÷ +50°C V.13.01.1 80-556 Gdańsk, Wielopole 7, POLAND, tel. (+48 58) 762-07-77, fax 762-07-70, www.simex.pl, e-mail: info@sim

 Open the catalog to page 1

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. SLN-44D

    2  Pages

  2. STH-42

    2  Pages

  3. SPP-638

    3  Pages

  4. SLC_30_46_47

    2  Pages

  5. SLN-44

    2  Pages

  6. SLE-42

    2  Pages

  7. SWZ-W610

    3  Pages

  8. SPP-N118

    3  Pages

  9. SPP-94

    3  Pages

  10. SPI-638

    3  Pages

  11. SPI-N118

    3  Pages

  12. SPI-94

    3  Pages

  13. STI-638

    3  Pages

  14. STI-N118

    3  Pages

  15. STI-94

    3  Pages

  16. STI-73

    3  Pages

  17. SLN-94

    3  Pages

  18. SLK-94T

    3  Pages

  19. SLIK-638

    3  Pages

  20. SLB-94

    3  Pages

  21. SLIK-94

    3  Pages

  22. SLIK-73

    3  Pages

  23. SLE-73

    3  Pages

  24. SLC-457

    3  Pages

  25. SLC-94

    3  Pages

  26. SCK-11

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.