Galvanic separator SGS-61 datasheet
1Pages

{{requestButtons}}

Catalog excerpts

Galvanic separator SGS-61 datasheet - 1

Sensors, transmitters, separators SGS-61 galvanic separator full galvanic isolation of 4-20 mA correction of characteristic thin DIN rail housing - 6,1 mm only Separator SGS-61 allows to input full galvanic isolation between transmitter and receiver of 4-20 mA current loop. Additionally it enables a possibility of connecting more than one receiver (e.g. two meters) with common ground in series in one current loop. Thanks to powering directly from current loop the device does not require any additional power supply, and full galvanic isolation allows using it in many applications with high requirements. Potentiometers which are available from the front, allow to trim minimum current and slope of characteristic, so the correction of whole current loop is possible. The device was built into a very thin housing (6,1 mm) designed for DIN rail mounting, what gives a possibility of its easy application in existing and being assembled systems. - powered directly from current loop, - trim minimum current and slope of characteristic, - very thin DIN housing - 6,1 mm only. Calibration The correction of system transmittance is realised via potentiometers P1, P2, available from the front after removing of small cap. P1 - regulation of 4,00 mA (@ IIN = 4,00 mA, min. current) P2 - regulation of 20,00 mA (@ IIN = 20,00 mA, slope) P1 P2 Technical data Input loop: Current: 4 ÷ 20 mA; IIN MIN = 3,9 mA; IIN MAX = 24 mA Voltage drop: max. 5,5 V Input side powered directly from input current loop Output loop: Current: 4 ÷ 20 mA; IOUT MIN = 3,9 mA; IOUT MAX = 24 mA Powering of output loop: 9 ÷ 30 V DC (any polarisation connected to OUT1, OUT2 ) Max load resistance: max. 1 kW (for 30 V / IOUT = 20 mA supply) After regulation it is recommended to check circuit characteristic for both 4 mA and 20 mA. Warning: proper sequence is necessary while circuit calibration. First potentiometer P1, next P2. Another data: Transmittance factor: KI = IOUT / IIN = 1 Bandwith: 200 Hz (3 dB) Separation: between input and output loops Insulation voltage: 750 V Temperature stability: 100 ppm / °C Operating temperature: 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) Storage temperature: -10°C ÷ +70°C (standard), -20°C ÷ +70°C (with option 08) Protection level: IP 20 Housing type: DIN rail mounted (35 mm rail) Housing dimensions: 80 x 6,1 x 93,8 mm Weight: 35 g Ordering SGS-61-1115-0-1-XX1 options: 00 : no options 08 : operating temp. -20°C ÷ +50°C V.13.01.1 80-556 Gdańsk, Wielopole 7, POLAND, tel. (+48 58) 762-07-77, fax 762-07-70, www.simex.pl, e-mail: info@sim

Open the catalog to page 1

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. STH-42

    2 Pages

  2. SPP-638

    3 Pages

  3. SLC_30_46_47

    2 Pages

  4. SLN-44

    2 Pages

  5. SLE-42

    2 Pages

  6. SWZ-W610

    3 Pages

  7. SPP-N118

    3 Pages

  8. SPP-94

    3 Pages

  9. SPI-638

    3 Pages

  10. SPI-N118

    3 Pages

  11. SPI-94

    3 Pages

  12. STI-638

    3 Pages

  13. STI-N118

    3 Pages

  14. STI-94

    3 Pages

  15. STI-73

    3 Pages

  16. SLN-94

    3 Pages

  17. SLK-94T

    3 Pages

  18. SLIK-638

    3 Pages

  19. SLB-94

    3 Pages

  20. SLIK-94

    3 Pages

  21. SLIK-73

    3 Pages

  22. SLE-73

    3 Pages

  23. SLC-457

    3 Pages

  24. SLC-94

    3 Pages

  25. MultiCon

    19 Pages

  26. SCK-11

    1 Pages

Archived catalogs

  1. SWS-99

    1 Pages