Process meters SRP-77 process meter with 2 displays inputs: 0/4-20 mA, 0/1-5V, 0/2-10V 0, 1 or 2 relay (or OC) outputs power supply output: 24V DC RS-485 / Modbus RTU programmable measuring range, indication filtration, hystereses and delays of control outputs free configuration software S-Config The SRP-77 meter is designed for measuring of typical current or voltage signals. The main advantages are two rows of display. The first one presents measuring value, second one - programmed values: max. and min. 1 or 2 relay (or OC) outputs make it possible to control processes ON/OFF type. Current input has protection safeguarding of the measuring resistor against damage. The device is dedicated to aplications, where there is necessity of continuous control of the threshold values. The RS-485 enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. SIMEX Ltd., Wielopole 11, 80-556 Gdansk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl
Open the catalog to page 1Process meters DIMENSIONS 5 Side view Case dimensions Panel cut-out dimensions ORDERING SRP-77-18XX-1-X-XX1 number of outputs: 0 1 2 type of outputs: 0 : no output 1 : REL 2 : OC options: 00 : no options 01 : IP 65 frame 08 : operating temp. -20°C ÷ +50°C 0P : operating temp. -20°C ÷ +50°C + IP 65 frame SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl
Open the catalog to page 2Meters accessories SECURITY DOOR WITH LOCK STD-77 transparent IP 54 door with lock for 72 x 72 mm case BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the configuration of most of them. For each detected device a list of its registers, which the user can modify, is displayed and also additional informations...
Open the catalog to page 32 Pages
96 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
19 Pages
1 Page
7 Pages
4 Pages
3 Pages
1 Page