Thermal deaerator

Thermal deaerator

Thermal deaerator

Product catalog summary
Overview
The document provides technical details about the SILHORKO-EUROWATER thermal deaerator, specifically the G15C-42A-Ukver3 model, which is designed for steam boilers and can handle up to 40 m3/hour. It is equipped with necessary armature and can be insulated.

Application
The thermal deaerator is used to treat feed water for steam boilers by removing oxygen to prevent corrosion. The make-up water typically contains 8-10 mg/l of oxygen, which is reduced to less than 0.05 mg/l after treatment.

General Operation
Heating the water liberates dissolved gases. The deaerator operates at an excess pressure of 0.2 bar, corresponding to a boiling point of 104°C, enhancing gas discharge by reducing water viscosity.

Theory of Operation
Condensate and make-up water are mixed to at least 60°C before entering the deaerator. A spray nozzle facilitates gas escape, while steam injectors create turbulence for efficient deaeration. Escaped gases are vented through a restricted gas vent.

Plant Design
The EUROWATER thermal deaerator type C complies with CE regulations and includes components like a steam pressure reducing valve, relief valve, level control, and more. The steel tank is coated for corrosion protection and can be insulated with mineral wool and an aluminium plate.

Specifications
The document includes a table detailing various modules (TA 2C to TA 40C) with specifications such as total tank volume, water volume, weight with and without water, and steam requirements. For example, the TA 2C module has a total tank volume of 1,450 litres and requires 162 kg/h of steam.

Contact Information
For further details, contact SILHORKO-EUROWATER A/S at +45 86 57 12 22 or [email protected].
See more

Catalog excerpts

Thermal deaerator-1

PURE WATER TREATMENT Thermal deaerator G15C-42A-Ukver3 Thermal deaerator - standard modules up to 40 m3/hour Reliable and efficient deaerator which is suitable for steam boilers, supplied complte with armature, and which can be supplied with insulation. Application A thermal deaerator is used for treatment of feed water for steam boilers. The feed water should not contain oxygen due to the fact that as long as oxygen is present in the water, corrosion will appear. If there is no oxygen present in the water, there will be no corrosion. The oxygen is supplied with the make-up water normally containing 8 - 10 mg/l. After treatment in a thermal deaerator, the oxygen content is reduced to less than 0.05 mg/l practically insoluble. Whether the heating takes place under vacuum or under pressure is in principle a secondary matter. Since an unproblematic operation with steam boilers demands a high and constant temperature, the thermal deaerator works at an excess pressure of 0.2 bar, which corresponds to a boiling point of 104 °C. Hereby, the discharge of the dissolved gases is increased, as the viscosity of the water is decreased at an increasing temperature. the top of the deaerator. A spray nozzle sprays the water in such a way that the gases can escape the layer surrounding every single water molecule. Steam is led to the bottom of the deaerator through a pressure-reducing valve, and steam injectors create the necessary turbulence in the water for an efficient deaeration. The escaped gases are led into the air through a gas vent with a restriction. For more information Please contact your local EUROWATER sales office. In general When the water is heated, the dissolved gases are liberated. If the temperature is raised sufficiently, the gases are Theory of operation The condensate and the make-up water are mixed so that a temperature of minimum 60 °C is obtained before it is led to SILHORKO-EUROWATER A/S 8660 Skanderborg Denmark Phone: +45 86 57 12 22 [email protected] www.eurowater.com Our World is Water

 Open the catalog to page 1
Thermal deaerator-2

Thermal deaerator G15C-42A-Ukver3 f Vapour / oxygen / undesirable gases Relief valve a Steam-»--CkK" Level switch Steam regulating valve Boiler feedwater - -HXr-^BXI Level switch HXh- From condensate tank Boiler feed pump Feed pump Plant design A EUROWATER thermal deaerator type C is constructed according to CE regulations and is CE marked. The deaerator is supplied complete with the necessary armature which comprises steam pressure reducing valve and relief valve, level control, water level indicator, thermometer, pressure gauge and sample valve with cooler. The deaerator tank is made of steel...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.