SR silencers are designed to reduce noise from Roots type blowers, vacuum pumps, and water ring or vane type rotary compressors. Developed through analogical research, these silencers are optimized for both suction and exhaust noise reduction.
Optional Extras
  • Flanges and counter flanges
  • Gaskets and bolts
  • Supports for vertical or horizontal positioning
  • Drains (standard on SRdS silencers)
  • Special steel construction
  • Zinc metallization for exterior protection
Contact the company for diameters above 450 mm.
Range
  • SRa: For suction and exhaust of air or dry gases
  • SRv and SRd: For exhaust of air or dry gases
  • SRdS: Separator silencers for vacuum pumps with air or gas containing liquid particles
The nominal diameter of inlet and outlet piping defines the silencer type.
Construction
Constructed entirely of welded steel, SR silencers have a zinc chromate rustproof exterior and an aluminum-painted interior. They can withstand a maximum pressure of 1 effective bar.
Assembly Instructions
  • Respect the gas flow direction indicated by an arrow on the silencer.
  • For SRd and SRdS, use piping no longer than three times the diameter for optimal acoustical efficiency.
  • Phonic insulation is recommended for high attenuation.
  • SRa, SRv, and SRd can be positioned horizontally or vertically; SRdS must be vertical.
  • Use flexible connections to prevent vibration transmission.
Model Descriptions
  • SRA Model: Absorption type, axial inlet and outlet, uses high-efficiency absorptive material.
  • SRV Model: Combines resonance and absorption, radial inlet, axial outlet, recommended for vacuum pump exhaust.
  • SRD Model: Combines reactive and dissipative principles, axial or lateral inlet, axial outlet, suitable for air or dry gas exhaust.
  • SRdS Model: Similar to SRd, includes liquid particle separation, must be installed vertically, suitable for vacuum pumps with liquid-loaded gases.
Acoustical Efficiency
Sound power attenuation is measured in decibels (dB) for each model.
Dimensional Characteristics
Tolerances vary by length: ±2 mm for 0-2 meters, ±3 mm for 2-4 meters, and ±5 mm for over 4 meters.
Choice of Nominal Diameter
Selection depends on the volume flow rate on the suction or exhaust side and the connecting diameter to the machine. A table provides maximum recommended flow rates.
See more

Catalog excerpts

SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-1

SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors SCOPE SR silencers are designed to efficiently reduce suction and exhaust noises of Roots type blowers, vacuum pumps and water ring or vane type rotary compressors. These silencers have been perfected in the laboratory by means of analogical research on A. BOET Co's simulator. Flanges and counter flanges. Sets of gaskets and bolts. Supports for vertical position (gussets) or horizontal position (frames). Drains (always provided on SRdS silencers). Construction in special steels. Exterior protection by zinc metallization Please get in touch with our Company for diameters above 450 mm. ASSEMBLY INSTRUCTIONS Four types of SR silencers are available, classified in three categories below: The direction of flow of gases must be respected. It is shown by an arrow on the housing of the silencer. • SRa type silencer for suction and exhaust of air or dry gases. • SRv and SRd type silencers for exhaust of air or dry gases. • SRdS type silencers or separator silencers of vacuum pumps with air or gas loaded with liquid particles. This is the case of water ring vacuum pumps or water injection Roots type blowers. • The nominal diameter of inlet and outlet piping defines the denomination of the silencers. In order to obtain the correct acoustical efficiency the inlet (machine side) of SRd and SRdS silencers should be fitted with piping of a maximum length equivalent to three times the diameter. For high attenuations it is recommended that a phonic insulation of the primary part of the silencers (volume) and of the upstream piping be provided, in order to prevent the transparency effect. SRa, SRv and SRd silencers can be placed in either a horizontal or a vertical position, depending on the space available and the layout of the piping. The SRdS silencer should always be placed in a vertical position. CONSTRUCTION SR silencers are entirely constructed in welded steel. A coat of zinc chromate rustproof paint has been applied to the exterior surfaces of these silencers and the interior is protected by a coat of aluminum paint. Maximum admissible pressure is 1 effective bar. It is sometimes advisable to separate the silencer from the machine by means of a flexible in order to prevent the transmissi

 Open the catalog to page 1
SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-2

SRA MODEL DESCRIPTION AND PRINCIPLE OF OPERATION ACOUSTICAL EFFICIENCY This silencer is of the < absorption > type. Inlet and outlet piping is axial. The gas flows through an annular space surrounded by an absorptive material in long fibers of a high acoustical efficiency and held in position and protected by a perforated sheet. AS ALREADY STATED This type of silencer is meant to be used for suction and exhaust of air or dry gas. Please get in touch with us if you require higher efficiencies. Sound power attenuation in dB DIMENSIONAL CHARACTERISTICS TOLERANCES: From 0 to 2 meters: ± 2 mm From...

 Open the catalog to page 2
SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-3

SRV MODEL DESCRIPTION AND PRINCIPLE OF OPERATION ACOUSTICAL EFFICIENCY This type of silencer is based on the combined principle of resonance and absorption of the sound wave. It allows a high attenuation to be obtained in all frequency bands and because of this it is especially recommended for exhaust of vacuum pumps. Radial inlet takes place in a volume covered by acoustical material with perforated sheet (resonance part) extended by the absorption part. Outlet piping is axial. AS ALREADY STATED Sound power attenuation in dB This type of silencer is meant to be used for suction and exhaust of...

 Open the catalog to page 3
SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-4

SRD MODEL DESCRIPTION AND PRINCIPLE OF OPERATION ACOUSTICAL EFFICIENCY This type of silencer allows a high attenuation of noise to be obtained in both low and high frequencies, by combining the reactive and dissipative principles. The axial or lateral inlet takes place in the reactive element made up of two volumes connected by a Venturi device. This element is completed by the absorption part. The outlet of the silencer is axial. AS ALREADY STATED This type of silencer should be used for exhaust of air or dry gases. Sound power attenuation in dB DIMENSIONAL CHARACTERISTICS TOLERANCES: From 0...

 Open the catalog to page 4
SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-5

SRdS MODEL DESCRIPTION AND PRINCIPLE OF OPERATION ACOUSTICAL EFFICIENCY This silencer allows the same acoustical attenuation as SRd silencers to be obtained. It is equipped with the same sound-proofing devices. Its lateral tangential inlet in the first volume ensures the separation of liquid particles by a gyratory movement of gases. The liquid is evacuated by a large sized drain that must be connected to the evacuation piping. It is imperative that the separator silencer be installed in a vertical position. Upon request it can be fitted with standard sup- porting legs. Outlet piping is axial....

 Open the catalog to page 5
SR Silencers for Roots type Blowers Vacuum Pumps Water Ring and vane type compressors-6

CHOICE OF NOMINAL DIAMETER OF SILENCER This choice depends on either the suction side volume flow rate or the exhaust side volumes flow rate. It can also take the connecting diameter to the machine into account. The opposite table shows the maximum recommended flow rates.

 Open the catalog to page 6

All SILEN Y SISTEM SL catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.