dLOG MINIATURE DATA LOGGERS TEMPERATURE / TEMPERATURE & HUMIDITY DATA LOGGERS Low cost and simple to use, the dLog series are self-contained, multiple-use, miniature button style temperature or temperature & humidity data loggers that can record up to 9,500 temperatures or 9,500 temperature and 9,500 relative humidity readings, with various temperature ranges and accuracies. All dLog data loggers have the ability to read the remaining battery life and it is also possible to download the data stored within the data logger if the battery is dead.
Open the catalog to page 1INTRODUCTION SECOND GENERATION BUTTON STYLE LOGGER The SL62T and SL63T are fully sealed and can be immersed in liquid without an additional protective enclosure. They are also food-safe with FULLY SEALED VERSIONS the construction materials certified by FDA. FOOD SAFE FDA AND BS EN 12830:2018 COMPLIANT All ‘A’ versions are supplied with an individual UKAS traceable calibration certificate and improved accuracy specification. A UKAS accredited calibration service is available upon request. Readings are stored in non-volatile memory so they can even be extracted if the battery is exhausted. Communication...
Open the catalog to page 2APPLICATION EXAMPLES FRIDGE & FREEZER MONITORING The high-security TempIT5 software platform ensures that the data recorded are a true and faithful record of the actual conditions your sensitive items have been exposed to. These are essential requirements for achieving the various facets of an FDA21 CFR Part 11 validated system or, as part of a hazard analysis & critical control point (HACCP) based food safety programme. Compliant to BS EN 12830:201 8. FACILITIES MANAGEMENT FOOD DISTRIBUTION & STORAGE PHARMACEUTICAL DISTRIBUTION PHARMACEUTICAL STORAGE MILK & DAIRY PRODUCTION COLD CHAIN CONTACT...
Open the catalog to page 3dLog SERIES - TECHNICAL SPECIFICATIONS TEMPERATURE RANGE ACCURACY RESOLUTION IP RATING TEMPERATURE RANGE ACCURACY RESOLUTION IP RATING * All ‘A’ versions come complete with UKAS 17025 traceable calibration certificates Low Cost Temperature Only Low Cost Temperature Only UKAS Traceable Cal Cert TEMPERATURE RANGE ACCURACY RESOLUTION IP RATING High Accuracy Temperature Only High Accuracy Temperature Only UKAS Traceable Cal Cert TEMPERATURE RANGE ACCURACY RESOLUTION IP RATING Wide Temperature Temperature Only Wide Temperature Temperature Only UKAS Traceable Cal Cert TEMPERATURE RANGE -40 to +125°C...
Open the catalog to page 4dLog SERIES - TECHNICAL SPECIFICATIONS PRODUCT TEMPERATURE RANGE RELATIVE HUMIDITY RANGE TEMPERATURE RESOLUTION HUMIDITY RESOLUTION RELATIVE HUMIDITY ACCURACY @ 25°C TEMPERATURE REPEATABILITY TEMPERATURE LONG-TERM DRIFT RELATIVE HUMIDITY REPEATABILITY RELATIVE HUMIDITY HYSTERESIS RELATIVE HUMIDITY LONG-TERM DRIFT RELATIVE HUMIDITY SENSOR MANUFACTURE Capacitive Polymer Dielectric VIRTUAL DEW POINT AND ABSOLUTION HUMIDITY CHANNELS LOGGING INTERVAL MAX READINGS
Open the catalog to page 5dLog SERIES - TECHNICAL SPECIFICATIONS continued... PRODUCT POWER SOURCE Yes. Battery life percentage remaining available through TempIT5. PHYSICAL SIZE ENCLOSURE MATERIAL Stirred Air: T63 141 Seconds T10-90 255 Seconds Stirred Water: T63 72 Seconds T10-90 132 Seconds Stirred Air: T63 150 Seconds T10-90 246 Seconds DOWNLOAD SPEED 60 seconds for 5,000 readings TempIT5 (Compatible with Microsoft Windows 7, 8, 10 & 11) LOGGING MODE Delayed Start, Then Level FOOD-SAFE APPROVALS Nylon 66 + 33% Glass Fibre TEMPERATURE Stirred Air: T63 150 Seconds T10-90 246 Seconds RESPONSE TIME Zytel® FGFE5171 Raw...
Open the catalog to page 6MECHANICAL OVERVIEW ACTUAL SIZE HUMIDITY SENSOR EXPOSURE TO CONTAMINANTS (SL64TH & SL64TH-A ONLY) Humidity sensors must not be exposed to articles or volatile chemicals such as solvents or other inorganic compounds. Typical ambient conditions do not present a significant risk for chemical exposure but some applications may contain a known source of volatile Contamination so exposure to a range of chemicals should be avoided. Exposure to the following chemicals is known to cause drift of the humidity output readings are often irreversible. SOLVENTS OTHER CHEMICALS, INCLUDING: Toluene: C7H8 Isopropyl...
Open the catalog to page 7CALIBRATION & RE-CALLIBRATION SERVICE Signatrol can provide you with an individual UKAS ISO 17025 traceable calibration certificate with each new data logger as an option *standard on all ‘A’ versions). In addition, we can also provide you with a 3-day turnaround UKAS ISO 17025 traceable re-calibration service for your existing data loggers (on a return-to-factory basis). We recommend that all out loggers are re-calibrated on at least an annual basis to ensure that they continue to perform to specification. We provide our standard 3-point default re-calibration or your own custom 3-point calibration...
Open the catalog to page 87 Pages
8 Pages
7 Pages
40 Pages
8 Pages
12 Pages
13 Pages
4 Pages