Overview: The document describes the Flame Ionisation Detector (FID) analysers designed for measuring the mass concentration of gaseous and vaporous organic substances in stationary source emissions. It highlights the features, specifications, and operational capabilities of the FID analysers.
Key Features:
  • Flexibility: Available with single or dual detectors, integrated zero air generator, and software suite for Ethernet use. Includes a built-in heated line controller.
  • Ease of Use: Rugged, portable design with a wireless tablet interface. Typical warm-up time is 30 minutes. Rated IP55 for protection.
  • Accuracy: Precision monobloc heated FID allows simultaneous monitoring of Total Hydrocarbons (THC), Non-Methane Hydrocarbons (NMHC), and Methane. Fast response time and compliance with EN12619 standards.
Measurement Technique: Utilizes Flame Ionisation Detector technology with user-selectable units in PPM or mg.
Measuring Ranges:
  • Range A: 0-1000ppm, user settable with a resolution of 0.01ppm.
  • Range B: 0-10000ppm, user settable with a resolution of 0.1ppm.
  • Range C: 0-100,000ppm, user settable with a resolution of 1ppm.
Performance Specifications:
  • Response Time: THC <1.5 secs, CH4 and NMHC <2.5 secs.
  • Repeatability: Less than 1% Full Scale Deflection (FSD).
  • Oxygen Effect: Less than 2% of reading from 0% to 21% O2.
  • Linearity: +/- 0.5% FSD or 2% of point.
  • Drift: +/-0.2ppm or 2% range per week.
  • Noise: +/-0.1ppm or 1% range.
  • Temperature Effects: On zero <0.15% per °C, on span <0.3% per °C.
Operational Conditions:
  • Sample Inlet Pressure: With internal pump: -0.6 to +0.4bar; without pump: +0.2 to +0.5bar.
  • Accuracy: Less than 0.2% FSD.
  • Precision: Less than 1%.
  • Detection Limit: 0.05mgC/m3.
  • Bypass Flow Sensitivity: Less than 2% from 1 to 3 L/min.
  • Sample Filter: Removable 0.4 micron PTFE and 7um non-removable stainless steel filter for CFID.
  • Sample Condition: 0-200°C for heated version, 0-80°C non-condensing for CFID.
Fuel and Air Supply:
  • Fuel Consumption: Single detector: 35ml/min H2 or 180ml/min H2He; Dual detectors: 70ml/min H2 or 360ml/min H2He.
  • Air Supply: Single detector: <1.1L/min; Dual detector: <1.6L/min.
Power and Connectivity:
  • Operating Conditions: 5-40°C ambient temperature.
  • Outputs: 0-10 Vdc, RS232, Ethernet, TCP/IP, optional 4-20 mA.
  • Power Requirements: 100 to 250Vac, optional 24VDC, 600W max.
  • Remote Control: AK protocol, Ethernet, with S4i remote software operating system.
Physical Specifications:
  • Size and Weight: 19” (w) x 133.5 (h) x 530 mm (d), approximately 22Kg.
  • IP Rating: IP55.
Manufacturer: Signal Group Ltd, Standards House, Doman Road, Camberley, Surrey GU15 3DF, United Kingdom. Contact: +44 (0)1276 682841, [email protected].
See more

Catalog excerpts

S4 SOLAR XPLORE-1

S4 SOLAR XPLORE Portable heated FID VOC analyser Flame Ionisation Detector (FID) analysers for the discontinuous measurement of the mass concentration of gaseous and vaporous organic substances in stationary source emissions. Flexible Single or dual detectors Integrated zero air generator Software suite for use over ethernet Built in heated line controller Easy to Use Rugged and portable Wireless tablet interface Typical warm up 30 minutes IP55 Rack mounted FID for continuous monitoring Accurate Precision monobloc heated FID Simultaneous monitoring of THC, NMHC & Methane Fast response time EN12619 compliant

 Open the catalog to page 1
S4 SOLAR XPLORE-2

S4 SOLAR XPLORE SPECIFICATIONS MEASUREMENT TECHNIQUE Flame Ionisation Detector NOISE +/-0.1ppm or 1% range, whichever greater MEASURING UNITS PPM or mg user selectable TEMPERATURE EFFECT ON ZERO <0.15% per oC MEASURING RANGES Range A: 0-1000ppm. User settable to e.g. 0-1ppm, 0-5ppm, 0-10ppm, 0-50ppm,0-100ppm, 0-500ppm, 0-1000ppm. Resolution:0.01ppm Range B: 0-10000ppm. User settable to e.g. 0-10ppm, 0-50ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-5000ppm. 0-10,000ppm. Resolution: 0.1ppm Range C. 0-100,000 ppm. User settable, with resolution of 1ppm RESPONSE TIME THC <1.5 secs CH4 and NMHC <2.5 secs...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.