Catalog excerpts
Do not risk your safety! PRODUCT CATALOGUE 2009 Made in www.sigmaelektrik.com
Open the catalog to page 1www.sigmaelektrik.com 01 CONTENTS CONTENTS Company Profile 04 Molded Case Circuit Breakers 07 Air Circuit Breakers 31 Miniature Circuit Breakers 45 Residual Current Circuit Breakers 59 Low Voltage Contactors 67 Low Voltage Instrument Transformers 95 Analog Panelmeters 109 Do not risk your safety! Digital Instruments 117
Open the catalog to page 3You are safe in Sigma City!
Open the catalog to page 4www.sigmaelektrik.com 04 ACMIDPAV COMPANY PROFILE Company Profile Sigma, which is one of the most leading Company in Turkish electromechanical Area, started its business with MCB (Miniature Circuit Breaker) in its own factory established in 1993 in Istanbul and continues to invest Turkish economy with its new projects improved with each passing day. In Sigma Elektrik all the working process from planning to the marketing are carried out under the guarantee of ISO 9000 Quality Management System. Each product is produced properly according to the IEC, VDE, EN and International Standards and...
Open the catalog to page 6www.sigmaelektrik.com 05 Short Circuit Testing Laboratory LABORATORY Sigma Elektrik owns the most comprehensive low voltage short circuit testing laboratory in which all the type test of low voltage switchgear and L/V distribution board can be made. Since 2003 October it has been used by TSE (Turkish Standards Institution) as a Subcontractor laboratory and accredited by TURKAK. With the Experiments of all low voltage switchgear according to IEC 947-1,2,3 and 4-1, up to 50 kA 1 second short periodical current experiments (thermal resistance) and up to 110 kA short circuit pulse current...
Open the catalog to page 7Molded Case Circuit Breakers LV Current Transformers LV Contactors & Thermal O/L Relays
Open the catalog to page 8Molded Case Circuit Breakers www.sigmaelektrik.com Do not risk your safety!
Open the catalog to page 9www.sigmaelektrik.com 10 MCCB Molded Case Circuit Breakers ACMIDPAV Ecowhite Series MCCB's Type KM 160 K100 No of Poles 1 3.4 Electrical Specifications Rated Current at 40° C A 25, 32, 40, 50, 63, 80 ,100, 125, 160, 200 25, 32, 40, 50, 63, 100 Rated Voltage Ue V AC 240 415 Rated Insulation Voltage Ui V 690 690 Rated Impuls Withstand Voltage Uimp kV 8 8 Breaking Capacitiy Rated Ultimate Short-circuit Breaking Capacity Icu kA 690 V AC 5 500 V AC 7 440 V AC 15 415 V AC 25 240 V AC 35 35 250 V AC 10 50 Rated Service Short - circuit Breaking Capacity Icu kA 690 V AC 5 500 V AC 7 440 V AC 10 415...
Open the catalog to page 12www.sigmaelektrik.com 12 Blue Power Series MCCB's Type H 160 No of Poles 3 Electrical Specifications Rated Current at 40°C A 25, 32, 40, 50, 63, 80, 100, 125, 160 Rated Voltage Ue V AC 415 Rated Insulation Voltage Ui V 690 Rated Impuls Withstand Voltage Uimp kV 8 Breaking Capacitiy Rated Ultimate Short-circuit Breaking Capacity Ics kA 690 V AC 8 500 V AC 9 440 V AC 22 415 V AC 36 240 V AC 50 250 V AC 40 Rated Service Short - circuit Breaking Capacity Ics kA 690 V AC 5 500 V AC 9 440 V AC 22 415 V AC 36 240 V AC 50 250 V AC 40 Utilisation Category A Pollution degree 3 Electrical life ON -...
Open the catalog to page 14www.sigmaelektrik.com 14 Thermal Magnetic Trip Thermal magnetic breakers are tripped by the bimetal heated by the load current. Bimetals are responsive to the heat emitted by the current flow so as to cause the operating mechanism to allow a long time delay on light overloads. Thermal magnetic breakers are also tripped through the use of electro magnet. This provides an instantaneaus tripping action when the current over the predetermined value flows. MCCB Molded Case Circuit Breakers Fixed Contact Moving Contact Trip Mechanism Thermo - Bimetal Handle Thermal Tripping Operation Mechanism...
Open the catalog to page 16www.sigmaelektrik.com 15 Current Limiting The assumed fault current Isc is the short-circuit current Isc that would flow, if there were no limitation, at the point of the installation where circuit-breaker is placed. Since the fault current is eliminated in less than one halfperiod, only the first peak current (asymmetrical peak) need be considered. This is a function of the installation fault cos. An electromagnetic repulsive force is where the forced works between a current of he movable conductor and current (i) in the reversed direction of the fixed conductor. This is an improvement of...
Open the catalog to page 17www.sigmaelektrik.com 20 Intelligent Unit for U1600 A MCCB's Electronic trip units are devices which guarantee a system of protection based on microprocessor electronics.In comparison with thermomagnetic trip units, they allow a mora precise seting both in therms of trip times as well as in terms of current thresholds in order to meet better the installation requirements. Electronic intelligent trip units, which can be mounted on U1600 type MCCB’s implement thi following protection functions. Protection against overloads (long time delay trip function) is identified by Functional L If the...
Open the catalog to page 22All SIGMA ELEKTRIK catalogs and technical brochures
-
ORDER CATALOGUE LOW VOLTAGE PRODUCTS
180 Pages
-
Relays
20 Pages
-
Low Voltage Contactors
46 Pages
-
Low voltage products
120 Pages
-
Low Voltage Power Capacitors
10 Pages
-
LV Surge Protection Devices
8 Pages
-
Modular Products
10 Pages
-
Miniature Circuit Breaker
32 Pages
-
Automatic Transfer Switches
18 Pages
-
L.V Air Circuit Breakers
18 Pages
-
LV CURRENT TRANSFORMERS
32 Pages
-
Panelmeter
19 Pages
-
MOULDED CASE CIRCUIT BREAKERS
42 Pages
-
Miniature Circuit Breakers
23 Pages
-
LV Contactor
39 Pages
-
AIR CIRCUIT BREAKERS
13 Pages