Catalog excerpts
Do not risk your safety! www.sigmaelektrik.com
Open the catalog to page 2ANALOG PANELMETERS ANALOG
Open the catalog to page 3G Analog Panelmeters ANALOG PANELMETERS Features • • • • • For measurement of AC currents and voltages Good read-out survey on larger distance Exchangeable dial Resistance to mechanical vibrations Protective cover for terminals Technical Specications Description Movement Type Accuracy Self Consumption Operating Voltage Test Voltage Construction & Desing Scale Glass Faceplate Mounting Fasteners/Clamps Temperature Conditions SA96 SA72 Moving iron meter of 90° deflection with interchangeable scale facility Moving iron spring-mounted jewel bearing suspencion ±1.5% of full scale as per EN 60051...
Open the catalog to page 4ANALOG PANELMETERS Analog Panelmeters ACMIDPAV Regulations and Standards Our meters and indicator/controllers comply with the regulations of the European Guidelines 73/23/EWG and 89/336/EVG. This is confirmed bby the compliance with the following standards: IEC/EN 61010-1/A2.VDE 0411-1/A1(Safety Regulations) IEC 60 051/EN 60 051/DIN EN 60051 (Meters with cale Display) EN 50 081-2:1993 EMC (Emitted Interference, Industries) EN 50 082-2:1995 EMC (Emitted Resistance, Industries) Given below are the most important regulations for the fabrication and the required properties of electrical meters....
Open the catalog to page 5Analog Panelmeters Effects of Vibration and Shock Unless otherwise specified, class 1 and higher measuring instruments and Accessories must withstand the following shock and vibration test. To which they are subjected during the course of type testing: Vibration Test Vibration testing must be performed with the following - Sweep frequency range: - Sweep velocity The vibration plane is vertical and the measuing instrument is mounted to the vibration table in its usual operating Connection to current transformer Direct connection Direct connection
Open the catalog to page 6ANALOG PANELMETERS Analog Panelmeters Insulation Voltage 2 kV for one minute between mechanism and casing, and between electrically insulated terminals. Vibration and Shock Resistance Our measuring instruments comply with requirements per DIN EN 60051-1 Model Vibration Test Shock Test Standard 10 Hz-55 Hz-10 Hz 0,15 mm [1.5 g at 50 Hz] 147 m/s2 [15 gn] 11 ms Excessive Stress 5 Hz-55 Hz-5 Hz 0.25 mm [2.5 g at 50 Hz] 294 m/s2 [30 gn] 11 ms Exchanging Of Scales Press the cover, on top of the instrument, in the direction of the arrow and extract the scale with a suitable toll. After exchanging...
Open the catalog to page 7Analog Panelmeters
Open the catalog to page 8Do not risk your safety! www.sigmaelektrik.com
Open the catalog to page 10DI Digital Instruments Universal Electronic Ammeter Digital ammeter is used to measure the AC current that goes the meter on its ring circuit. It also can be used in other working condition that is on the purpose of current measuring. The max value of the instantaneous conveyanoc current should not ezceed 5A. The transforming rate of the can be set from 1/5A to 5000/5 with the panel pushbutton. When the power sutting over, the class value set can be kept in the meter and the meter can be working on this condition. The working power supply input terminals(1-2) and the measuring signal...
Open the catalog to page 11DI Digital Instruments Dimensions SD96A Control Panel Cut Out 73 mm 68 mm 92 mm 90 mm 90 mm 64 mm 90 mm 68 mm 92 mm SD72A SD96A (72x72) 66 mm 66 mm 76 mm SD96A (96x96) 83 mm 66 mm The Area Measurements on The Control Panel Wall Wall 73 mm 64 mm 90 mm 66 mm 83 mm 76 mm SD96A SD72A 50 mm 50 mm *Warning: No need of a vantilator in the installation area Connection Diagram Technical Data: Auxiliary Supply (Un) : 230VAC Operating Range : (0.9-1.1)x Un Measuring Range : 0-5A Measurement Category : CAT III Class SD72A Amperemeter 4 3 : 1%+1 digit [(10%-100%)Xfull scale] o o Ambient Temperature : -5...
Open the catalog to page 12DI Digital Instruments Digital Voltmeter Digital voltmeter is used to measure the AC voltage that goes through the meter on its ring circuit lt also can de used in other working condition that is on the purpose of voltage measuring. The max value of the instantaneous conveyance voltage should not exceed 600V The working power supply input terminals (3-4) and the measuring signal connection terminals (1-2) are on the back board of the meter and the display screen is on the front panel. Precautions For Installation And Safe Use • Failure to follow those instruction will result in death or...
Open the catalog to page 13DI Digital Instruments Control Panel Cut Out Dimensions SD96V 73 mm 90 mm 68 mm 92 mm 90 mm 90 mm 64 mm 92 mm SD72V SD96V 76 mm (72x72) 66 mm SD96V (96x96) 83 mm 66 mm 68 mm 66 mm Connection Diagram SD96V Voltmeter 4 3 SD72V Voltmeter 2 1 4 3 2 1 1A Measuring Input L N 1A Measuring Input L N Technical Data: Auxiliary Supply (Un) : 220VAC Operating Range : (0.9-1.1)x Un Operating Frequency : 50/60Hz. Measuring Range : 0-600V~ Measurement Category : CAT III Class : 1%+1 digit [(10%-100%)Xfull scale] Ambient Temperature : -5°C;+50°C Display : Red LED Display *Please check the device label for...
Open the catalog to page 14DI Digital Instruments Ordering Digital AC Ammeter Type Description Spcications Dim. mm Pacage pcs. Box pcs. Cat Number. SD 96A Ammeter 1-5000/5A with CT 96x96 1 60 SD96A-5000 SD 72A Ammeter 1-5000/5A with CT 72x72 1 100 SD72A-5000 Digital AC Voltmeter Type Dim. mm Pacage pcs. Box pcs. Cat Number. Voltmeter 0-500 V AC 96x96 1 60 SD96V-0600 SD 72V 122 Spcications SD 96V www.sigmaelektrik.com Description Voltmeter 0-600 V AC 72x72 1 100 SD72V-0600
Open the catalog to page 15Do not risk your safety!
Open the catalog to page 18VİTAMİN NOVA 0212 507 18 31 - 61 Do not risk your safety! Ekşioğlu Mah. Yeni Şile Cad. No:40 34794 Alemdağ - Çekmeköy / İstanbul / TURKEY Phone: +90 216 429 72 01 (pbx) Fax : +90 216 484 41 01 sigma@sigmaelektrik.com www.sigmaelektrik.com ISO 9001 : 2000 Made in
Open the catalog to page 19All SIGMA ELEKTRIK catalogs and technical brochures
-
ORDER CATALOGUE LOW VOLTAGE PRODUCTS
180 Pages
-
Relays
20 Pages
-
Low Voltage Contactors
46 Pages
-
Low voltage products
120 Pages
-
Low Voltage Power Capacitors
10 Pages
-
LV Surge Protection Devices
8 Pages
-
Modular Products
10 Pages
-
Miniature Circuit Breaker
32 Pages
-
Automatic Transfer Switches
18 Pages
-
L.V Air Circuit Breakers
18 Pages
-
SIGMA ELEKTRIK PRODUCTS CATALOGUE
134 Pages
-
LV CURRENT TRANSFORMERS
32 Pages
-
MOULDED CASE CIRCUIT BREAKERS
42 Pages
-
Miniature Circuit Breakers
23 Pages
-
LV Contactor
39 Pages
-
AIR CIRCUIT BREAKERS
13 Pages