General Information
Surge protection devices are designed to safeguard electrical equipment from overvoltages caused by lightning. They can be installed on main and auxiliary panels, and even near sockets for precise protection. These devices comply with German standard VDE 0675-6, international standard IEC 61643-1, and European standard EN 61643-11.

Surge Arrester Classes
- Class B, Type 1, Class I: Used for main distribution panels with a maximum protection capacity of 100kA.
- Class C, Type 2, Class II: Used for distribution boxes with a maximum protection capacity of 40kA.
- Class D, Type 3, Class III: Used in auxiliary tables with a maximum protection capacity of 5kA.

Key Specifications
- Up Protection Level: The reduced high voltage value due to lightning, ranging from 1 to 2.5 kV.
- Imax, Maximum Current Rate: The maximum discharge current the arrester can withstand once, expressed in kA.
- In, Rated Current Rate: The current rate during testing that the arrester can conduct without issues, expressed in kA.
- Uc, Surge Arrester Operating Voltage: The maximum operating voltage under normal conditions, expressed in V.

Product Connection and Technical Dimensions
Each class and type of surge arrester has specific connection diagrams and technical dimensions to ensure proper installation and functionality.

Order Information
Details on the types, definitions, number of poles, operating voltage, maximum current, rated current, and protection level are provided for ordering purposes. Note that LV surge arresters, except for type B, come with a fault signal contact.
See more

Catalog excerpts

LV Surge Protection Devices-1

LV S urg e Pr ote ctio nD evic Mód es Con ulo s De tra Sob ret Protec ens ione ción Baj o Vo s De ltag e

 Open the catalog to page 1
LV Surge Protection Devices-2

LV SURGE PROTECTION DEVICES Módulos De Protección Contra Sobretensiones De Bajo Voltage

 Open the catalog to page 2
LV Surge Protection Devices-3

Lv Surge Protection Devices Módulos De Protección Contra Sobretensiones De Bajo Voltage Content General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 Surge Arrester Selection . . . . . . . . . . . . . . . . . . . . . . . .169 Información General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Eligiendo Módulo De Protección . . . . . . . . . . . . . . . . . . . 169 Up Protection Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Imax, Maximum Current Rate . . . . . . . . . . . . . . . . . . . . . . . . . . In, Rated Current Rate ....

 Open the catalog to page 3
LV Surge Protection Devices-4

Sigma ^^elektrik Lv Surge Protection Devices <U> Modulos De Proteccion Contra Sobretensiones De Bajo Voltage © In, Rated Current Rate Refers to the rate of current, which is applied during test stage and that surge arrester can conduct without any problem. It is signified in terms of kA Uc, Surge Arrester Operating Voltage Refers to the maximum operating voltage of a surge arrester in the network under normal conditions, it is signified in terms of V Sigma surge arresters are produced in 3 different categories based on capacity in accordance with protection degrees; Type 1: has maximum 100kA...

 Open the catalog to page 4
LV Surge Protection Devices-5

Esquema Electrico Y Medidas Tecnicas 49 Wiring diagram Esquema de conexiones Technical dimensions Medidas tecnicas L/N Fuse Fusible Wiring diagram Technical dimensions Esquema de conexiones Medidas tecnicas

 Open the catalog to page 5
LV Surge Protection Devices-6

Lv Surge Protection Devices <U> Modulos De Proteccion Contra Sobretensiones De Bajo Voltage © Class C, Type 2, Class II Clase C, Tipo 2, Clase II Product Connection Diagram And Technical Dimensions SP1-C040 Esquema Electrico Y Medidas Tecnicas L/N Fuse Fusibk Wiring diagram Esquema de conexiones Technical dimensions Medidas tecnicas Type Tipo Fuse Fusible Wiring diagram Esquema de conexiones Technical dimensions Medidas tecnicas 174

 Open the catalog to page 6
LV Surge Protection Devices-7

Fuse Fusible Technical dimensions Medidas tecnicas Wiring diagram Esquema de conexiones Fuse Fusible

 Open the catalog to page 7
LV Surge Protection Devices-8

Lv Surge Protection Devices Módulos De Protección Contra Sobretensiones De Bajo Voltage Esquema Eléctrico Y Medidas Mécnicas Product Connection Diagram And Technical Dimensions SP1-D005 Equipment to be protected Equipo a proteger Order Information Definition Fuse Fusible Datos Del Pedido No of poles Order code Type 1, class B use before the electricity meter Tipo 1 clase B colocación anterior al contador Type 2, class C use aſter the electricity meter Tipo 2 clase C colocación posterior al contador Type 2, class C use aſter the electricity meter Tipo 2 clase C colocación posterior al contador Type...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.