L.V Air Circuit Breakers
18Pages

{{requestButtons}}

Catalog excerpts

L.V Air Circuit Breakers - 1

LV A ir C ircu it B rea Inte ker rru s pto res Aut Bas omáti tido cos r Ab De iert o

Open the catalog to page 1
L.V Air Circuit Breakers - 2

LV Air Circuit Breakers Interruptores Automáticos De Bastidor Abierto

Open the catalog to page 2
L.V Air Circuit Breakers - 3

Lv Air Circuit Breakers Interruptores Automáticos De Bastidor Abierto Content Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . .62 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Draw-Out Type LV Air Circuit Breakers . . . . . . . . . . . .63 Especificaciones Técnicas . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Información General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Interruptores Automáticos De Bastidor Abierto Con Bandeja . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 3
L.V Air Circuit Breakers - 4

Lv Air Circuit Breakers <U> Interruptores Automates De Bastidor Abierto © Technical SpecificationsEspecificaciones Tecnicas Type Tpo

Open the catalog to page 4
L.V Air Circuit Breakers - 5

Lv Air Circuit Breakers Interruptores Automáticos De Bastidor Abierto General Information Información General Sigma LV air circuit breakers function to protect and separate the circuit to which they are connected, from over load and short circuit currents. When they are equipped with a motor mechanism, they are ready to perform switch off at any time. Los interruptores automáticos de bastidor abierto cumplen la función de proteger y separar el circuito al que se encuentran conectados de corrientes de cortocircuito y las sobrecargas. Al contar con un mecanismo de motor siempre está preparado...

Open the catalog to page 5
L.V Air Circuit Breakers - 6

Sigma ^^elektrik Lv Air Circuit Breakers <U> Interruptores Automaticos De Bastidor Abierto © Long Time Reverse Time Delayed Overcurrent Protection De Sobrecarga Con Retardo Largo De Protection (Ir1) Tiempo Inverso (Ir1) Other Characteristics Of Control Circuit • Current passing through the circuit display function • Phase-Phase and Phase-Neutral voltages display function • Fault current and time display function • Alarm option • Frequency display function • Test function Issues To Be Taken into Consideration With Regard To Control Circuit • It is essential to press on firstly the CLEAR...

Open the catalog to page 6
L.V Air Circuit Breakers - 7

Lv Air Circuit Breakers di> Interruptores Automates De Bastidor Abierto • Trip and Non-Trip buttons are only for test. if supply voltage is not applied in test circuit, it doesn’t work. • It is essential to pay attention to long-term delay current (Ir1) < short-term delay current (Ir2) < Instant Tripping current (Ir3) conditions while performing current setting so that circuit breaker could perform active protection. Los botones de Trip y Non-Trip son solo para pruebas (test). No funcionan si durante el circuito de prueba no se aplica corriente de alimentation. Para que el Interruptor de...

Open the catalog to page 7
L.V Air Circuit Breakers - 8

Lv Air Circuit Breakers Interruptores Automáticos De Bastidor Abierto Esquema De Conexión Del Circuito De Control Control Circuit Connection Diagram Main circuit Circuito principal Overload trip Disparo de sobrecorriente Emergency trip Apertura de emergencia Electrical trip Apertura eléctrica J2 Fault Fallo Electrical closing Cierre eléctrico Auxiliary switch Llave auxiliar Energy storage Carga de energía Off switch Interruptor de apagado Power supply SA Processing unit Unidad de procesado Electronic trip Disparo electrónico Not: Closing and tripping coils must not be leſt under constant...

Open the catalog to page 8
L.V Air Circuit Breakers - 9

Lv Air Circuit Breakers di> Interruptores Automates De Bastidor Abierto 3. 3. When I (PUSH ON) button is pressed, switch contacts are closed and ON-OFF indicator takes ON position, and set up mechanism energy storage indicator takes “Discharged” position. 4. When 0 (PUSH OFF) button is pressed switch contacts are opened and ON-OFF indicator takes OFF position, and set up mechanism energy storage position remains under “Discharged” position. Note: As set up operation shall be performed after each ON-OFF operation automatically in circuit breakers with motor set up, circuit breaker is always...

Open the catalog to page 9
L.V Air Circuit Breakers - 10

Sigma ^^elektrik Lv Air Circuit Breakers <U> Interruptores Automates De Bastidor Abierto © Contacto Auxiliar Auxiliary Contact Auxilary contacts change the position in parallel with the ON and OFF contact positions of the circuit breaker, helps to receive and lock out audible and illuminated signals. 4NO+4 NC auxiliary contacts in Sigma power circuit breakers are delivered as a standard to the customers as attached to the switch. Maximum thermic current which auxiliary contacts can carry is 6 A. Motor Mechanism Motor mechanism makes the power switch ready for closing by setting up the set...

Open the catalog to page 10
L.V Air Circuit Breakers - 11

Lv Air Circuit Breakers di> Interruptores Automates De Bastidor Abierto Caractensticas De Tiempo-Corriente De Sobrecarga Para Los Interruptores Automaticos Overcurrent Protection Current-Time Curve De Bastidor Abierto Caractensticas De Tiempo-Corriente De La Protection Contra Corriente Residual Para Los Earth Fault Protection Current-Time Curve Interruptores Automaticos De Bastidor Abierto

Open the catalog to page 11
L.V Air Circuit Breakers - 12

Sigma ^^elektrik Lv Air Circuit Breakers <U> Interruptores Automates De Bastidor Abierto © Overcurrent Protection Current-Time Curve Curva De Tiempo Corriente De Protection Contra Sobrecarga Earth Fault Protection Current-Time Curve Curva De Tiempo Corriente De Protection De Fallo De Toma A Tierra 10000 Type / Tipo

Open the catalog to page 12
L.V Air Circuit Breakers - 14

Lv Air Circuit Breakers <U> Interruptores Automates De Bastidor Abierto © SDA-2000 Type / Tipo Type / Tipo

Open the catalog to page 14
L.V Air Circuit Breakers - 16

Lv Air Circuit Breakers <U> Interruptores Automates De Bastidor Abierto © Order Information Information De Pedido3 Poles Fixed Type LV Air Circuit Breakers Interruptores Automaticos De Bastidor Abierto FijosDe 3 Polos Type code Codigo Oe tipo Note: (*) LV air circuit breakers are delivered as 4NO+4NC Auxiliary contact block is attached. Nota: Los interruptores automaticos de bastidor abierto se despachan con el bloque de contacto auxiliar 4NO+4NC montado. 4 Poles Fixed Type LV Air Circuit Breakers Interruptores Automaticos De Bastidor Abierto Fijos De 4 Polos Type code Rated current In (A)...

Open the catalog to page 16