Quick Start SPD3303X/3303X-E Programmable DC Power Supply

Open the catalog to page 1
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 3

Copyright and Statement Copyright SIGLENT TECHNOLOGIES CO., LTD. All rights reserved. Trademark Information SIGLENT is registered trademark of SIGLENT TECHNOLOGIES CO., LTD. Statement • SIGLENT products are protected by patent laws in and outside of the P.R. China. • SIGLENT reserves the rights to change the specification and price. • Information in this publication replaces all previous corresponding published material. • Contents in this manual are not allowed to be copied, extracted or translated in any form or by any means without SIGLENT’s permission.

Open the catalog to page 3
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 4

General Safety Summary Please review the following safety precautions carefully to avoid personal injury or damage to this product or any product connected to it. To prevent potential danger, please use the instrument as specified. Use proper power cord Only the power cord designed for the instrument and authorized by local country could be used. Power supply AC Input Voltages: 100V/110V/220V/230V ±10%, 50/60Hz. Use proper fuse The fuse types: 100V/110V: T6.3A/250V; 220V/230V: T3.15A/250V; Make sure to use the correct type of fuse before turning on the instrument. Do not connect the power...

Open the catalog to page 4
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 5

Do not operate in an explosive atmosphere To avoid personal injury or damage to instrument, please do not operate in an explosive atmosphere. Keep surface of the product clean and dry To avoid dust or moisture in the air influence the performance of the instrument , please keep surface of the product clean and dry.

Open the catalog to page 5
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 6

Safety Terms and Symbols Terms may appear on the product: DANGER: Indicates direct injury or hazard that may happen. WARNING: Indicates potential injury or hazard that may happen. CAUTION: Indicates potential damage to the instrument or other property that may happen. Symbols may appear on the product: Hazardous Voltage Protective Earth Ground

Open the catalog to page 6
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 7

SPD3303X/3303X-E Brief Introduction SPD3303X/3303X-E Programmable DC Power Supply is convenient, flexible and multi-function. It has three independent outputs, two sets of adjustable voltage value and a fixed set of selectable voltage value of 2.5V, 3.3V, and 5V, and it also provides output short circuit and overload protection at the same time. 4.3” TFT color LCD display with content of 16M; Three independent outputs, two of which are adjustable, and the total power up to 195W; Four kinds of input voltage values includes 100V, 110V, 220V and 230V to satisfy different requirements; Function...

Open the catalog to page 7
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 9

Chapter 1 Start Guide In this chapter, we mainly introduce the panel and display Interface of SPD3303X/3303X-E, as well as the new machine inspection and attentions at first use. Reading this chapter will give you a quick understanding on operation. Brief introduction: • General Inspection • The front panel • The rear panel • User interface • The rear panel • Output check

Open the catalog to page 9
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 10

General Inspection Please check the instrument according to the following steps. 1. Inspect the shipping container. Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement. 2. Inspect the instrument. If there are instruments found damaged, defective or failure in electrical and mechanical tests, please...

Open the catalog to page 10
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 11

Safety Considerations To ensure that the instrument can work normally, please conduct necessary inspection before using the SPD3303X/3303X-E Input Power Requirement The SPD3303X/3303X-E allows a 50Hz/60Hz frequency, and four levels of AC power: 100V/120V/220V/230V. You can select wanted power voltage with the “DIP Switch” at the rear panel according to the actual demand. Warning To switch to the wanted power voltage, please disconnect the power cord first. Electrical Check Please use the power cord provided as accessory and connects the instrument to AC power. Check the power as the...

Open the catalog to page 11
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 12

configuration button © Multi-function knob © Fine Adjust button © Right/Left Direction button Channel Control button 14 CV/CC indicator light

Open the catalog to page 12
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 13

Buttons for setting parameters Press the button to turn on/off the waveform display interface; Press the button to set series mode of CH1/CH2, and the logo “ ” displays at the same time; Press the button to set parallel mode of CH1/CH2, and the logo “ ” displays at the same time; Press the button to enter the LAN setting and storage function interface Press the button to enter timer setting interface Press the button longer to turn on/off the keylock function and shorter to turn to system information interface Buttons for controlling the channel Press the button to turn on/off all the...

Open the catalog to page 13
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 14

Other buttons Select the digit position by moving the cursor around Right/Left Direction button. Press the button to move the cursor around The output terminal on front panel The output terminals of CH1, CH2 and CH3 include positive terminal and negative terminal, and a common ground for CH1 and CH2 additional. Each channel has its own logo. The operation details are introduced in the follow-up ”control panel operation”.

Open the catalog to page 14
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 15

Parallel/Series logo: The logo will be displayed when the corresponding mode is on Channel logo Operating mode logo: The corresponding logo will display when working in CV or CC mode; LAN logo: It will display when there is a LAN connection USB logo: It will display when there is a USB connection; Readback value; Timer lD: Timer state identification;

Open the catalog to page 15
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 16

warning message The DIP switch of the AC power and its identification. The description of the AC input voltage

Open the catalog to page 16
Siglent SPD3303X/3303X-E Programmable DC Power Supply Quick Start - 17

Output check The output check includes voltage check in condition of all channels with no load and current check in condition of short circuit so as to make sure that the instrument correctly responds to operation of the front panel. 1. Voltage output check (1) Within no load, turn on the power, and make sure the setting current values of all channels are not zero; (2) Turn on CH1/CH2 and the instrument work in constant voltage mode. Check whether the voltage value could be changed from 0V to 32V. 2. Current output check (1) Turn on the power, and make sure the setting current values of all...