SHS800 Series Handheld Digital Oscilloscope Application Domain ♦ Wind power, PV power and other new energy equipment test ♦ Automotive electron, electric automobile test ♦ Electric power system,strong electricity test ♦ Industry scenes electric debug testing and measuring ♦ Education and science research Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 1V/ ggg§lg ■_5IGLENT TECHNOLOGIES CO.,LTD Features & Benefits ♦ Dual-input,combine oscilloscope, Multimeter and recorder (including TrendPlot and waveform Recorder) in one ♦ Input voltage: input voltage through BNC is up to CAT II 300V and CAT III 150V Oscilloscope and multimeter safety grade is up to CAT II 600V and CAT III 300V ♦ 5.7 inch TFT color LCD display ♦ Max. 200MHz Bandwidth, 1GSa/s real-time sampling rate single channel, up to 50GSa/s equivalent sampling rate, 2Mpts memory depth ♦ With 6000 dots display resolution Multimeter and provides measurements of DCV, ACV, DCI, ACI,...
Open the catalog to page 2Scope Recorder ♦ Recording scope waveform continually in scan mode ♦ Support recording, replay and zoom function ♦ 7M points memory depth, 18 hours recording time ♦ Maximum 4GB in USB storage mode, 3000hours recording time ♦ 6000 counts high percison Multimeter ♦ Providing measurements of DCV, ACV, DCI, ACI, Resistance, Diode, Capacitance, Continuity Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 3Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 4Technical Specifications Oscilloscope Acquisition System Sampling Types Real time, Equivalent Sampling Mode Sampling, Peak detection, Average Average Times Input System Input Coupling Input Impedance Probe Attenuation Factor Probe Attenuation Factors Set Max. Voltage From BNC ( Reference Max. Floating Voltage From Multimeter Reference to Earth Ground Single Channel Common Mode Rejection Ratio Channel-to-Channel Isolation Horizontal System Real time Sample Rate Interaction Mode Single Channel :50Sa/s1GSa/s Double Channels: 50Sa/s500MSa/s x, Sinx Channel Mode Sample Rate Single Channel Single...
Open the catalog to page 5Vertical System Vertical Sensitivity Channel Vertical Resolution Analog Bandwidth DC Measurement Accuracy ≤200mv/div DC Measurement Accuracy 200mv/div Rise Time Vertical Input Coupling Math Operation Window Mode: Hanning, Hamming, Blackman, Rectangular Sampling: 1024 points 20MHz (-3dB) Trigger System Trigger Types Edge, Pulse Width, Video, Slope, Alternative Trigger Source Trigger Modes Auto, Normal, Single Trigger Coupling Trigger Level Range CH1, CH2: ±6 divisions from center of screen Trigger Displacement Pre-trigger: Memory depth/(2*sampling) Delay Trigger: 268.04div Holdoff Range Edge...
Open the catalog to page 6Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 7Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 8Handheld Digital Oscilloscope SHS800 serise Know more information, welcome visit www.siglent.com
Open the catalog to page 9Type Selections: Standard accessories: Two test leads for multimeter Probe calibration accessory A USB data transmitting cable User Manual Warranty Card A CD of Easyscope used for PC control Optional probe 100MHz high-voltage safety probe CAT II 1000V,CAT III 600V 200MHz high-voltage safety probe CAT II 1000V,CAT III 600V To obtain service,warranty or technical assistance,please contact us directly: Add: 3/F, Building 4, Antongda industry area, 3rd LiuXan Rd, Baona District, ShenZhen, China. E-mail :sales@siglent.com Http://www.siglent.com Handheld Digital Oscilloscope SHS800 serise Know...
Open the catalog to page 10All Siglent Technologies Co. catalogs and technical brochures
-
SDS6000A Series
21 Pages
-
SDS 7000A Series
21 Pages
-
SDL1000X Series
10 Pages
-
SSM5000A Series
15 Pages
-
Spectrum Analyzer Bandwidth
6 Pages
-
Siglent_Product Catalog 2016
48 Pages
-
Siglent Selection Guide 2016
10 Pages
-
Benefits of deep memory
3 Pages
-
SIGLENT Probes Datasheet
7 Pages
-
Siglent SDS2000X User Manual
197 Pages
-
Siglent SDS2000X Service Manual
59 Pages
-
Probe Data Sheet + Siglent
7 Pages
-
USB-GPIB User Manual_Siglent
13 Pages
-
ISFE User Manual
12 Pages
-
Siglent TrueArb Technology
9 Pages
-
SDS2000 VS DS2000A_EN_Siglent
10 Pages
-
SIGLENT SDS1000CFL
8 Pages