Siglent Selection Guide 2016
10Pages

{{requestButtons}}

Catalog excerpts

Siglent Selection Guide 2016 - 1

01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 01010101010101010101010101010101010101010101 Digital Oscilloscope 01010101010101010101010101010101010101010101 Waveform Generator 01010101010101010101010101010101010101010101 DC Power Supply 01010101010101010101010101010101010101010101 Digital Multimeter 01010101010101010101010101010101010101010101 The Best Value in Electronic Spectrum Analyzer 01010101010101010101010101010101010101010101 Test & Measurement Handheld Oscilloscope 01010101010101010101010101010101010101010101 Probes & Accessories 01010101010101010101010101010101010101010101 Product Selection Guide

Open the catalog to page 1
Siglent Selection Guide 2016 - 2

Super Phosphor Oscilloscope Features and Benefits: • 70 MHz, 100 MHz, 200 MHz, 300 MHz models • Real-time sampling rate up to 2 GSa/s • New generation of SPO technology • Waveform capture rate up to 140,000 wfm/s (normal mode), and 500,000 wfm/s (sequence mode) • Supports 256-level intensity grading and color temperature display • Record length up to 140 Mpts Features and Benefits: • 100 MHz, 200 MHz bandwidth models • Real-time sampling rate up to 1 GSa/s • New generation of SPO technology • Waveform capture rate up to 60,000 wfm/s (normal mode),and 400,000 wfm/s (sequence mode) • Supports...

Open the catalog to page 2
Siglent Selection Guide 2016 - 3

Digital Storage Oscilloscope • Provide 2/4 analog channels, 24 Kpts memory depth • 2 GSa/s real time sampling rate, 50 GSa/s equivalent sampling rate • 7 inch (8*18 div) color TFT-LCD • Trigger types: Edge, Pulse, Video, Slope and Alternative • Interface: Dual USB Host,USB Device, LAN, Pass/Fail • 32 kinds of automatic waveform measurements and unique digital filter function • 6 digits hardware frequency counter, real time counting display • Support USB-TMC, VXI-11 protocol and SCPI programming command control • 50 MHz, 70 MHz, 100 MHz, 150 MHz bandwidth models • Real-time sampling rate up...

Open the catalog to page 3
Siglent Selection Guide 2016 - 4

Function/Arbitrary Waveform Generator Features and Benefits • 4.3 inch color TFT-LCD, DDS technology ,dual channels output, phase adjustable • 500 MSa/s sampling rate,14 bit vertical resolution,512 Kpts max wave length • 2 ppm high frequency stability, -116 dBm/Hz low phase noise • Output signal and the rack earth is isolated to ensure the purity of testing system • Excellent high frequency-high amplitude characteristic ,amplitude can reach 20 Vpp(high impedance ) with a 40 MHz output frequency • Output pulse signal with low jitter ,fast rising ad falling edge (independent from frequency) •...

Open the catalog to page 4
Siglent Selection Guide 2016 - 5

Programming Linear DC Power Supply Digital Multimeter • 3 independent controlled and isolated outputs, 32 V/3.2 A×2, 2.5 V/3.3 V/5 V/3.2 A×1, total 220 W • 5 digits Voltage, 4 digits Current Display, Minimum Resolution: 1 mV/1 mA (SPD3303X) • Supports front panel timing output functions • 4.3 inch true color TFT- LCD 480x272 display • 3 types of output modes: independent, series, parallel • 100 V/120 V/220 V/230 V compatible design to meet the needs of different power grids • Intelligent temperature-controlled fan, effectively reducing noise • Clear graphical interface, with the waveform...

Open the catalog to page 5
Siglent Selection Guide 2016 - 6

Spectrum Analyzer Handheld Oscilloscope • All-Digital IF Technology • Frequency Range from 9 kHz up to 3.2 GHz • -161 dBm/Hz Displayed Average Noise Level (Typ.) • -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.) • Total Amplitude Accuracy < 0.7 dB • 10 Hz Minimum Resolution Bandwidth (RBW) • Standard Preamplifier • Up to 3.2 GHz Tracking Generator Kit (Opt.) • Reflection Measurement Kit (Opt.) • Advanced Measurement Kit (Opt.) • EMI Pre-compliance Measurements Kit (Opt.) • 10.1 lnch WVGA (1024x600) Display • Completely isolated oscilloscope channels, isolated between oscilloscope and...

Open the catalog to page 6
Siglent Selection Guide 2016 - 7

Probes and Accessories Type Specifications PB470,70 M bandwidth PP510,100 MHz bandwidth PP215,200 MHz bandwidth PP430,300 MHz bandwidth 1 X/10 X decay, 1 M/10 Mohm, 300 V/600 V Bandwidth 250 MHz, fixed 10X decay, the rise time of about 1.2 ns, Passive Probe input capacitance: 16 pF, compensation range: 10 pF-35 pF, input impedance 10 MΩ, length 120 cm, safe voltage levels: CAT II 1000 V, CAT III 600 V Bandwidth 300 MHz, fixed 10 X decay, the rise time of about 1ns, input PB830 capacitance: 16 pF, compensation range: 10 pF-20 pF, input impedance 10 MΩ, length 140 cm, safe voltage levels: CAT...

Open the catalog to page 7
Siglent Selection Guide 2016 - 8

Specifications Bandwidth: 50 MHz; Maximum input differential voltage 800 V (DC + Peak AC); Range selection (attenuation ratio):10 X/100 X; Accuracy: ±1%; Standard DC 9 V/1 A power adapter Bandwidth: 70 MHz; Maximum input differential voltage 1500 V (DC + DPB5150 Peak AC); Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%; Standard 5 V/ 1 A USB power adapter High Voltage Differential Probe Bandwidth: 100 MHz; Maximum input differential voltage 1500 V (DC + DPB5150A Peak AC); Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%; Standard 5 V/ 1 A USB power adapter...

Open the catalog to page 8
Siglent Selection Guide 2016 - 9

Deskew fixture Supporting power analysis software for calibration phase voltage and current probes generated during transmission N-N cable for SSA3000X Series; 6 GHz bandwidth N-BNC cable for SSA3000X Series; 2 GHz bandwidth N-SMA cable for SSA3000X Series; 6 GHz bandwidth VSWR Bridge Kit for SSA3000X Series: Reflection Bridge including Refl-SSA3000X (Software), VSWR Bridge(1 MHz~2 GHz), N(M)-N(M) adaptor (2 pcs) Utility Kit for SSA3000X Series: N (M) -SMA (M) cable, N (M) -N (M) cable, N (M) -BNC (F) adaptor (2 pcs), N (M) -SMA (F) adaptor (2 pcs), 10 dB attenuator;

Open the catalog to page 9
Siglent Selection Guide 2016 - 10

About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales,production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, isolated handheld oscilloscopes and other general purpose test instrumentation. Since its first oscilloscope, the ADS7000 series, was...

Open the catalog to page 10

All Siglent Technologies Co. catalogs and technical brochures