Siglent SDS1000X/X+ Series Oscilloscope Data sheet
15Pages

{{requestButtons}}

Catalog excerpts

Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 1

Digital Oscilloscope

Open the catalog to page 1
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 2

Key Features 200 MHz, 100 MHz bandwidth models Real-time sampling rate up to 1 GSa/s New generation of SPO technology • Waveform capture rate up to 60,000 wfm/s (normal mode), and 400,000 wfm/s (sequence mode) • Supports 256-level intensity grading and color temperature display • Record length up to 14 Mpts • Digital trigger system Overview SIGLENT’s new SDS1000X/SDS1000X+ Series Super Phosphor Oscilloscopes are available in two bandwidths, 100 MHz and 200 MHz, have a sampling rate of 1 GSa/s and a standard record length of 14 Mpts. The most commonly used functions can be accessed with its...

Open the catalog to page 2
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 3

Models and Key Specifications Model 7 Mpts/CH (Dual-Channel); 14 Mpts/CH (Single-Channel) Waveform Capture Rate (Max.) 60,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode) Trigger Type Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video Serial Trigger Decode Type (Optional) Single Channel, Max. Frequency up to 25 MHz, 125 MSa/s sampling rate, 16 Kpts wave length SDS1000X+ Supported (Standard); SDS1000X Not supported 16 Digital Channels (MSO Maximum waveform capture rate up to 500 MSa/s, Record length up to 14 Mpts/CH Option) SDS1000X+ Supported (Optional);...

Open the catalog to page 3
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 4

Characteristics Waveform capture rate up to 400,000 wfms/s 256 intensity grading and color temperature display With a waveform capture rate of up to 400,000 wfm/s (sequence mode), SPO display technology provides for fast refresh rates. The resulting the oscilloscope can easily capture the unusual or low-probability events. intensity-graded trace is brighter for more often-occurring display points and dimmer in less-often-occurring points Color Temperature Display Record length of up to 14 Mpts Using hardware-based Zoom technologies and record length of up to The color temperature display is...

Open the catalog to page 4
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 5

History Waveforms (History) mode and Comprehensive statistical functions segmented acquisition (Sequence) Playback history waveform to observe unusual events and locate the Parametric statistical functions to display any parameters of the source quickly through the cursor or measurements, located on the five measurements: current, average, minimum value, maximum keyboard Panel,this function is easily enabled. Segmented memory value, and the standard deviation. The measurement count is also collection will store the waveform into multiple (up to 80,000) memory displayed. The maximum number...

Open the catalog to page 5
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 6

Specifications Acquire System Sampling Rate 1 GSa/s (Single-Channel), 500 MSa/s (Daul-Channel) Memory Depth Max 14 Mpts/Ch (Single-Channel), 7 Mpts/Ch (DualChannel) Peak Detect Waveform interpolation Sinx/x, Linear 1 MΩ ≤400 Vpk(DC + Peak AC <=10 kHz), 50 Ω ≤5 Vrms DC~Max BW >40 dB Probe attenuator Vertical Resolution Vertical Scale (Probe 1X) Offset Range (Probe 1X) Bandwidth Limit ST-DEV ≤0.7 division (<1 mV/div) ST-DEV ≤0.3 division(<2 mV/div) ST-DEV ≤0.2 division(≥2 mV/div) SFDR including harmonics Offset Accuracy Rise time Horizontal System Time base Scale Channel Skew Waveform Capture...

Open the catalog to page 6
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 8

Dropout Trigger Time out Type Edge, State Rising, Falling Time Range Runt Trigger Polarity Limit Range Time Range Pattern Trigger Pattern Setting Limit Range Time Range Window Trigger Window Type Absolute, Relative Serial Trigger I2C Trigger Condition Start, Stop, Restart, No Ack, EEPROM, 7 bits Address & Data, 10 bits Adress & Data, Data Length Source (SDA/SCL) Data format Limit Range Data Length EEPROM: 1 byte Addr & Data: 1~2 byte Data Length: 1~12 byte Addr & Data: Read, Write, Do not care Source (CS/CL/Data) Data format Data Length UART/ RS232 Trigger Condition Start, Stop, Data,...

Open the catalog to page 8
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 9

All, Remote, ID, ID + Data, Error Data Format Data Length Baud Rate (Selectable) Baud Rate (Custom) Break, Frame ID, ID+Data, Error Data Format Data Length Baud Rate (Selectable) Baud Rate (Custom) Serial Decoder (Optional) I2C Decoder Signal Edge Select Rising, Falling UART/ RS232 Decoder Signal Data Width Parity Check Idle Level CAN_H, CAN_L CAN_H, CAN_L, CAN_H-CAN_L LIN Decoder LIN Specification Package Revision

Open the catalog to page 9
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 11

Math Function Digital Channels (Optional for SDS1000X+) Rectangular, Blackman, Hanning, Hamming Full Screen, Split Memory Depth Decoding number Min. Detectable Pulse 4 ns Width Built-in Function Generator (Standard for SDS1000X+) Channel Level Range Logic Type TTL, CMOS, LVCMOS 3.3, LVCMOS 2.5, custom Level Group D0~D15: ±1 sampling interval Digital to Analog: ± (1 sampling interval +1 ns) Sampling Rate Frequency Resolution Frequency Accuracy Vertical Resolution Amplitude Range USB Host, USB Device, LAN, Pass/Fail, Trigger Out Waveform Type Sine, Square, Ramp, Pulse, DC, Noise, Cardiac,...

Open the catalog to page 11
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 12

SDS1000X/SDS1000X+ Probes & Accessories Type Logic Probe Passive Probe 16 Channel Logic Probe Bandwidth: 100 KHz; Maximum continuous current 20 Arms; CP4020 Peak current 60 A; Switching ratio: 50 mV/A; 5 mV/A; DC measurement accuracy: 50 mV/A (0.4 A-10 ApK) ± 2%; 5 mV/A (1 A-60 ApK)±2%; 9 V battery-powered Bandwidth: 1 MHz; Maximum continuous current 50 Arms; Peak current 140 A; Switching ratio: 500 mV/A; 50 mV/A; DC measurement measurement accuracy: 500 mV/A (20 mA-14 ApK) ±3%±20 mA; 50 mV/A (200 mA-100 ApK )±4%± 200 mA; 50 mV/A (100 A-140 ApK)±15% max; 9 V battery-powered Bandwidth: 150...

Open the catalog to page 12
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 13

Maximum input differential voltage 1500 V (DC + Peak AC); Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%; Standard 5 V/1 A USB power adapter High Voltage Differential Probe Maximum input differential voltage 7000 V (DC + Peak AC); Range selection (attenuation ratio): 100 X/1000 X; Accuracy: ±2%; Standard 5 V/1 A USB power adapter Bandwidth: 100 MHz; Maximum input differential voltage 7000 V (DC + Peak AC); Range selection (attenuation ratio): 100 X/1000 X; Accuracy: ±2%; Standard 5 V/1 A USB power adapter Bandwidth: 40 MHz; High Voltage Probe Maximum measurement voltage DC:...

Open the catalog to page 13
Siglent SDS1000X/X+ Series Oscilloscope Data sheet - 14

Ordering information Product Description Product Name 100 MHz Two Channels, Built-In Waveform Generator (Standard), 16 Digital Channels (Option, *Requires SPL1016 & SDS-1000X-LA) 200 MHz Two Channels, Built-In Waveform Generator (Standard), 16 Digital Channels (Option, *Requires SPL1016 & SDS-1000X-LA) Standard Accessories USB Cable -1 Quick Start-1 Certification-1 Passive Probe-2 Power Cord -1 CD (Included User Manual and EasyScopeX software)-1 Optional Accessories I2C,SPI,UART/RS232,CAN,LIN Decoder 16 Digital Channels Logic Probe High Voltage Probe Current Probe Differential Probe

Open the catalog to page 14

All Siglent Technologies Co. catalogs and technical brochures