Introduction
The SDS1000X-E Series Super Phosphor Oscilloscope by SIGLENT TECHNOLOGIES is a digital oscilloscope designed for electronic testing applications. This guide provides instructions for setting up and operating the oscilloscope safely and effectively.
General Safety Summary
Users should adhere to safety precautions to prevent injury or damage. Key measures include using the correct power cord, ensuring grounding, avoiding high voltage connections, and maintaining ventilation. Electrostatic discharge precautions and specified fuses are also important.
Quick Start Guide
  • General Inspection: Check the shipping container and instrument for damage and verify all accessories are present.
  • Adjusting and Connecting: Stabilize the oscilloscope, connect it to AC power, and perform a power-on inspection.
  • Probe Connection: Connect the probe to the oscilloscope and test circuit, ensuring correct waveform display.
  • Probe Compensation: Adjust the probe for accurate measurements by comparing waveforms to reference figures.
Front and Rear Panel Overview
Descriptions of the front and rear panel components, including the LCD display, universal knob, function menus, and control buttons. The rear panel includes LAN, USB, and power interfaces.
Trigger Functions
The oscilloscope supports various trigger types such as Edge, Slope, Pulse, Video, and Serial Bus triggers, with specific configurations and applications explained.
Conclusion
This guide provides essential setup and usage information for the SDS1000X-E Series Oscilloscope. Users should refer to the full manual for detailed specifications and advanced features.
Overview
The document details instructions and specifications for the SDS1000X-E Series Digital Oscilloscope, covering trigger types, control settings, and troubleshooting steps.
Trigger Types
  • SPI Trigger: Options to trigger on MISO or MOSI data with variable data lengths.
  • UART/RS232 Trigger: Trigger on start, stop, checksum error, or data with specific data widths.
  • CAN Trigger: Trigger on start, remote, ID, ID+DATA, or error of CAN signals.
  • LIN Trigger: Trigger on start, ID, ID+DATA, or data error.
Control Settings
  • Trigger Modes: Auto, Normal, and Single modes available.
  • Level Adjustment: Adjustable trigger level, resettable to 50% of waveforms.
  • Vertical Control: Includes position and scale adjustments, math operations, and reference waveform functions.
  • Run Control: Set to RUN or STOP states with button indicators.
  • Waveform Intensity: Adjustable intensity, graticule, and transparency.
Additional Features
  • Universal Knob: For menu navigation and parameter modification.
  • Cursor Function: Manual and track cursor modes available.
  • Measurement Settings: Set measurement types and statistical functions.
  • Sample Menu: Options for acquisition mode, interpolation mode, and memory depth.
  • File Management: Supports saving and recalling setups, waveforms, pictures, and CSV files.
User Interface
  • Includes product logo, channel labels, working states, horizontal time base, trigger position, frequency counter, sample rate, and memory depth displays.
Troubleshooting
  • Guidance on resolving issues like dark screens, missing waveforms, incorrect voltage amplitude, unstable waveforms, and USB recognition problems.
Contact Information
Contact details for SIGLENT offices in America, Headquarters in China, and Europe.
See more

Catalog excerpts

Siglent SDS1000X-E Series QuickStart-1

SDSIOOOX-E Series Super Phosphor Oscilloscope Quick Start

 Open the catalog to page 1
Siglent SDS1000X-E Series QuickStart-2

Copyright Information SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved. Declaration SIGLENT products are protected by patent law in and outside of P.R.C. SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding material. Any way of copying, extracting or translating the contents of this manual is not allowed without the permission of SIGLENT. Note: SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD. SIGLENT TECHNOLOGIES CO., LTD. Address:...

 Open the catalog to page 2
Siglent SDS1000X-E Series QuickStart-3

General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Use Proper Power Cord Only the power cord designed for the instrument and authorized by local country could be used. Ground the Instrument The instrument is grounded through the protective earth conductor of the power cord. To avoid electric shock, please make sure the instrument is grounded correctly before connecting its input or output terminals. Use Proper Overvoltage...

 Open the catalog to page 3
Siglent SDS1000X-E Series QuickStart-4

Safety Terms and Symbols General Care and Cleaning Terms on the product. These terms may appear on the product: Indicates direct injuries or hazards that may happen. DANGER WARNING Indicates potential injuries or hazards that may happen. CAUTION Indicates potential damages to the instrument or other property that may happen. Do not store or leave the instrument in direct sunshine for long periods of time. Notice: To avoid damages to the instrument or probe, please do not leave them in fog, liquid, or solvent. Cleaning Please perform the following steps to clean the instrument and probe regularly...

 Open the catalog to page 4
Siglent SDS1000X-E Series QuickStart-5

1- SDS1000X-E Series Digital Oscilloscope

 Open the catalog to page 5
Siglent SDS1000X-E Series QuickStart-6

Quick start General Inspection 1. Inspect the shipping container Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement if the instrument has been damaged in shipment. Figure 1 2-Channel Scope Front View Figure 2 4-Channel Scope Front View 2. Inspect the instrument If there are instruments found damaged,...

 Open the catalog to page 6
Siglent SDS1000X-E Series QuickStart-7

Quick start Adjust the Supporting Legs Connect to AC Power Supply Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement as well as easier operation and observation of the instrument. The oscilloscope accept 100-240V, 50/60/440Hz AC power supply. Please use the power cord provided as accessories to connect the instrument to the power source as shown in the figure below. Power Socket Before adjusting After adjusting To Connect to Power Supply(2Channel Scope) Power Socket To Connect to Power Supply(4Channel Scope) Note: If at any time the...

 Open the catalog to page 7
Siglent SDS1000X-E Series QuickStart-8

Quick start Power-on Inspection When the scope is energized, turn on the power switch at the lower left corner on the front panel. During the start-up process, the instrument performs a series of self-test items and you can hear the sound of relay switching. After the self-test completed, the User Interface displays immediately. Connect the Probe Compensation Signal Output Terminal Ground Terminal SIGLENT provides passive probe for the SDS1000X-E series oscilloscope. Please refer to corresponding Probe User Manual for detailed technical information. Connect the probe: 1.Connect the BNC terminal...

 Open the catalog to page 8
Siglent SDS1000X-E Series QuickStart-9

Probe Compensation You should properly compensate the probe at first use of it. Non-compensated or inadequate compensated probe may cause inaccurate measurement. The following steps are about probe compensation: 1. Perform step 1, 2,3 and 4 of "Functional Inspection" 2. Check the displayed waveforms and compare them with the following figure. Under Compensated over Compensated Correctly Compensated 3. Use a nonmetallic driver to adjust the low-frequency compensation adjustment hole on the probe until the waveform changes to be correct as the figure above. 5- SDS1000X-E Series Digital...

 Open the catalog to page 9
Siglent SDS1000X-E Series QuickStart-10

4-channel scope front panel 4 1. LCD Display 2. Universal Knob 3. Common Function Menus 4. Clear Sweeps 5. Run/Stop 6. Decode 7. Auto Setup 8. Navigate 9. History 10. Default 11. Vertical Control, Math, REF and Digital 12. Horizontal Control 13. Trigger Control 14. Menu on/off ① WARNING: Non-standard HDMI interface, Siglent device ONLY, or you will damage your devices. SDS1000X-E Series Digital Oscilloscope -6 15. Menu Softkey 16. One- Button shortcut for Save 17. Analog Channel 18. Power Button 19. USB Host 20. SBUS Digital Inputs ① 21. Probe Compensation/ Ground Termina

 Open the catalog to page 10
Siglent SDS1000X-E Series QuickStart-11

l.User Interface 2.Universal Knob 3.Function Menus 4.Run/Stop 5.Auto Setup 7- SDS1000X-E Series Digital Oscilloscope

 Open the catalog to page 11
Siglent SDS1000X-E Series QuickStart-12

l.Handle Pull up the handle vertically for easy carrying of the instrument. When you do not need the handle, press it down. 2.LAN The instrument can be connected to network via this interface to perform remote control. 3.USB Device The oscilloscope support SCPI remote control commands, user can control the oscilloscope through this interface 4.USB Host 5.Safety lock Hole You can lock the instrument to a fixed location using the security lock (please buy it yourself) via the lock hole. 6.AC Power Socket AC power input terminal. The power requirements of this oscilloscope are 100-240 V, 50/60/400...

 Open the catalog to page 12
Siglent SDS1000X-E Series QuickStart-13

2-channel scope rear panel 1. Handle Pull up the handle vertically for easy carrying; press it down if you do not need the handle. 2.Safety Lock Hole You could lock the instrument in a fixed location using a security lock (please buy it yourself ) via the lock hole 3. LAN Interface The instrument can be connected to network via this interface to perform remote control 4. Pass/Fail or Trig Out Output Via this interface the oscilloscope can output a signal that can reflect the current capture rate of the instrument at each trigger or a Pass/Fail pulse. 5.USB Device SDS1000X-E series support SCPI...

 Open the catalog to page 13

All Siglent Technologies Co., Ltd catalogs and technical brochures

  1. SDS6000A Series

    21  Pages

  2. SDL1000X Series

    10  Pages

  3. SSM5000A Series

    15  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.