DataSheet SDS1000CFL Series Digital Oscilloscope SIGLENT TECHNOLOGIES Co.,LTD Add: 3/F, Building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China Tel: +86-755-3661 5186 Fax: +86-755-3359 1582 E-mail: [email protected] Website: www.siglent.com
Open the catalog to page 1The volume of the oscilloscope is cabinet and it is portable Single real-time sampling rate is:2GSa/s, Equivalent sampling rate is 50GSa/s. Memory depth is 24Kpts. Trigger types: Edge, Pulse, VideoSlope and Alternative Unique Digital Filter function and Waveform recorder function Auto measure thirty two parameters and support all measurement function. Two/Four groups’reference waveforms and twenty groups’ capture waveforms and twenty groups’ setups internal save/recall function and USB flash drive save/recall function. Cursor types: Manual mode, Track mode and Auto mode. Channel waveform and...
Open the catalog to page 2Specifications All specification applies to 10X probe and All the SDS1000CFL Series Digital Storage Oscilloscopes. To verify that the oscilloscope meets specifications, the oscilloscope must first meet the following conditions: ● The oscilloscope must have been operating continuously for thirty minutes within the specified operating temperature. ● You must perform the Do Self Cal operation, accessible through the Utility menu, if the operating temperature changes by more than 5° C. ● The oscilloscope must be within the factory calibration interval All specifications are guaranteed unless noted...
Open the catalog to page 3Vertical Resolution Channels Analog Bandwidth Single-shot Bandwidth Lower frequency limit ≤10Hz(at input BNC) (AC -3dB) ≤0.6 Div for average of 10 Pk-Pk readings, Fixed Noise: Pk-Pk for 3K gain settings record ≤0.7 Div for average of 10 Pk-Pk readings, Variable gain settings SFDR including harmonics >=35dB (measured with FFT) ±3.0%: 5mv/div to 5V/div in Fixed Gain Ranges DC Gain Accuracy ±4.0%: 2mv/div Variable Gain Ranges DC Measurement Accuracy: ±[3%* |reading|+|offset| +1% *of |offset| All Gain +0.2div+2mv] settings≤100mv/div DC Measurement Accuracy: ±[3%* |reading|+|offset| +1%* of |offset|...
Open the catalog to page 4Math operation FFT Bandwidth limited Horizontal System Real Time Sampling Rate Equivalent Sampling Rate Measure Display Modes Timebase Accuracy Horizontal Scan Range +, -, *, /, FFT Window mode: Hanning, Hamming, Blackman, Rectangular Sampling points: 1024 20MHz ±40% (Note: BW limited below 20MHz when using probe in x1) Single Channel: 2GSa/s, Double Channels: 1GSa/s (When timebase faster than 25ns/div) The highest equivalent sampling rate of other Models is 50GSa/s MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y ±100ppm measured over 1ms interval 1.0nS/DIV - 50S/DIV Scan: 100mS/DIV 50S/DIV (1-2.5-5 sequence)...
Open the catalog to page 5Video Trigger Slope Trigger Alternative Trigger X-Y Mode X-pole Input / Y-Pole Input Sample Frequency Support signal Formats: PAL/SECAM, NTSC Trigger condition : odd field, even field, all lines, line Num (,, ) Positive slope, (,, ) Negative slope Time: 20ns-10s CH1 trigger type: Edge, Pulse, Video, Slope CH2 trigger type: Edge, Pulse, Video, Slope CH3 trigger type: Edge, Pulse, Video, Slope CH4 trigger type: Edge, Pulse, Video, Slope (CH1) / (CH2) or (CH3)/(CH4) XY mode has a breakthrough that trad oscilloscopes restrict sampling rate at 1MSa/s. Support 25Ksa/s 250Msa/s adjusted. Hard Ware Frequency...
Open the catalog to page 6Generic Specification Display System Display Mode Resolution Display Color Display Contrast Typical state Backlight IntensityTypical state Wave display range Wave Display Mode Persist Menu Display Screen-Saver Skin waveform interpolation Color model Language Color TFT 7.0in.(177.8mm)diagonal Liquid Crystal Display 480 horizontal by 234 vertical pixels 64K color 150:1 300nit 8 x 18 div Dots, Vector Off, 1 sec, 2 sec, 5 sec, Infinite 2 sec, 5 sec, 10 sec, 20 sec, Infinite Off,1min,2min,5min,10min,15min,30 min,1hour,2hour,5hour Classical, Modern, Tradition, Succinct Sin(x)/xLinear Normal , Invert...
Open the catalog to page 7Standard Accessories: ● 1:1/10:1 probe (2/4 PCS based on channels) ● Power Cable that fits the standard of destination country ● Qualified Certification. ● Guaranty Card ● CD (including EasyScope computer software system) ● User Manual ● USB Cable SIGLENT TECHNOLOGIES Co.,LTD Add: 3/F, Building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China Tel: +86-755-3661 5186 Fax: +86-755-3359 1582 E-mail: [email protected] Website: www.siglent.com