Catalog excerpts
SIGLENT TECHNOLOGIES User Manual Product Introduction RBSSA3X20 Reflection Bridge Instructions The Siglent RBSSA3X20 is used in connection with SIGLENT's SSA3000X series of spectrum analyzers to measure Sll-related parameters such as return loss, reflection coefficient and VSWR. The RBSSA3X20 also provide 2 N(M)-N(M) adapters to facilitate connection with SSA3000X's ports. The reflection bridge has 3 ports as shown in the figure: -IN(TG):Signal input terminal.This terminal connects to the TG terminal of -OUT(RF):Signal output terminal. This terminal connects to the RF input terminal of the spectrum analyzer -DUT: This port is connected to the Device Under Test The distance between the SSA3000X's TG and Input ports is designed to match that on the RBSSA3X20 in order to improve accuracy by eliminating the need for extra hook-up cables. Refleclion Bridge Measurement Procedure The connection of RBSSA3X20 and spectrum analyzer is shown in the Use 2 N(M)-N(M) adapters to connectthe output terminal of the tracking generator and the RF input terminal I of the spectrum analyzer to the IN terminal and OUT terminal of the reflection bridge respectively. 1) Press Mode->Reflection Meas, to access the Reflection Measurement mode. The Tracking Generator Tracking Generator indicator light will activate and the screen will appear as below: Reflection Table Disconnect the DUT before press the "Cal Open Load', Connectthe DUT when the "Cal Open Load' pressed. 2) In the Reflection Measurement mode the user can modify certain spectrum analyzer parameters such as Frequency, Amplitude, and BW, in those related menus.
Open the catalog to page 1SIGLENT TecHNOLOGies UserManual 3) Connect the DUT terminal of Reflection Bridge with an open load, or leave it unterminated. Press Cal Open Load. The analyzer screen will now appear as below: Reflection Table Marker Trace Type
Open the catalog to page 2All Siglent Technologies Co. catalogs and technical brochures
-
SDS6000A Series
21 Pages
-
SDS 7000A Series
21 Pages
-
SDL1000X Series
10 Pages
-
SSM5000A Series
15 Pages
-
Spectrum Analyzer Bandwidth
6 Pages
-
Siglent_Product Catalog 2016
48 Pages
-
Siglent Selection Guide 2016
10 Pages
-
Benefits of deep memory
3 Pages
-
SIGLENT Probes Datasheet
7 Pages
-
Siglent SDS2000X User Manual
197 Pages
-
Siglent SDS2000X Service Manual
59 Pages
-
Probe Data Sheet + Siglent
7 Pages
-
USB-GPIB User Manual_Siglent
13 Pages
-
ISFE User Manual
12 Pages
-
Siglent TrueArb Technology
9 Pages
-
SDS2000 VS DS2000A_EN_Siglent
10 Pages
-
SIGLENT SDS1000CFL
8 Pages
-
SIGLENT SHS800 Data Sheet
10 Pages