SIGLENT Series SIGLENT TECHNOLOGIES CO.,LTD
Open the catalog to page 1Passive Probe Parameter Attenuation Rate Input Impedance Input Capacitance Compensation Range Input Voltage Operation Temp Cable Length Attenuation Rate Input Impedance Input Capacitance Compensation Range Input Voltage Operation Temp Cable Length
Open the catalog to page 2Current Probe Parameter Rise time Peak-Peak Value Range Switch Power Supply Max. rated voltage to earth Conductor Size Cable Length Rise time Peak-Peak Value Range Overload Value Current Transfer Ratio Measurement Resolution DC Accuracy Power Supply Max. rated voltage to earth
Open the catalog to page 3High Voltage Differential Probe Model Rise time Attenuation Ratio Max Differential Test Voltage (DC + Peak AC) Max input common Mode voltage (voltage-to-earth Vrms) Single-ended to Input ground Impedance Two inputs Input Capacitance CMRR Noise (Vrms) Propagation Delay Bandwidth limit Differential overvoltage Detection level Null Null Overload indicator(red light) Overload Alarm Automatic Save Offset Setting function Terminate Load Power Supply Probe body dimensions Probe body weight High Voltage Probe Model Rise time Single / Noise Attenuation Ratio Input Impedance Input Capacitance...
Open the catalog to page 4Logic Probe Parameter Input Impedance Input Impedance Pod 2: D15-D8 Pod 1: D7-D0 TTL (1.5 V), COMS (2.5 V) , 3.3 V_LVCOMS (1.65 V), 2.5 V_LVCOS (1.25 V) Threshold Groupings Threshold Selections Threshold Groupings Threshold Selections Pod 2: D15-D8 Pod 1: D7-D0 TTL (1.5 V), COMS (2.5 V), 3.3 V_LVCOMS (1.65 V), 2.5 V_LVCOS (1.25 V) User defined threshold range User defined threshold range Threshold Accuracy Threshold Accuracy Input Dynamic Range Input Dynamic Range Min. Input Voltage Swing Min. Input Voltage Swing Min. Detectable Pulse Width Min. Detectable Pulse Width Channel Skew ±(1...
Open the catalog to page 5Near Field Probe Parameter Frequency Range It can be used at a distance of up to 10 cm from the units. The probe detects the spatial distribution of HF magnetic fields in devices and assemblies and allows the user to draw conclusions with regard to disturbance emissions. Frequency range:30 MHz to 3 GHz It is suitable for measurements u p t o 3 c m . In t e r fe re n c e sources can be localized by detecting the distribution and orientation of the field, therefore enabling a more exact use of higher resolution probes. Frequency range: 30 MHz to 3 GHz It is suitable for measurements u p t o 3...
Open the catalog to page 6DataSheet SIGLENT Series Probe About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, isolated handheld oscilloscopes and other general purpose test instrumentation. Since its first...
Open the catalog to page 7All Siglent Technologies Co. catalogs and technical brochures
-
SDS6000A Series
21 Pages
-
SDS 7000A Series
21 Pages
-
SDL1000X Series
10 Pages
-
SSM5000A Series
15 Pages
-
Spectrum Analyzer Bandwidth
6 Pages
-
Siglent_Product Catalog 2016
48 Pages
-
Siglent Selection Guide 2016
10 Pages
-
Benefits of deep memory
3 Pages
-
Siglent SDS2000X User Manual
197 Pages
-
Siglent SDS2000X Service Manual
59 Pages
-
Probe Data Sheet + Siglent
7 Pages
-
USB-GPIB User Manual_Siglent
13 Pages
-
ISFE User Manual
12 Pages
-
Siglent TrueArb Technology
9 Pages
-
SDS2000 VS DS2000A_EN_Siglent
10 Pages
-
SIGLENT SDS1000CFL
8 Pages
-
SIGLENT SHS800 Data Sheet
10 Pages