Service Manual SDS2000X Series Digital Oscilloscope

Open the catalog to page 1
SIGLENT/oscilloscope/SDS2000X/service manual - 3

Copyright SIGLENT TECHNOLOGIES CO., LTD All Rights Reserved. Trademark Information SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD Declaration • SIGLENT products are protected by patent law in and outside of P.R.C. • SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company’s sole decision. • Information in this publication replaces all previously corresponding material. • Any method of copying, extracting or translating the contents of this manual is not allowed without the permission of SIGLENT. • SIGLENT will not...

Open the catalog to page 3
SIGLENT/oscilloscope/SDS2000X/service manual - 4

General Safety Summary Review the following safety precautions to avoid personal injuries and prevent damages to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Personal Injuries Use Proper Power Cord. Use only the power cord specified for this product and approved by your local governing agencies. Avoid Electric Shock. To avoid injuries or potential loss of life, do not connect or disconnect probes or test leads while they are connected to a voltage...

Open the catalog to page 4
SIGLENT/oscilloscope/SDS2000X/service manual - 5

Avoid Circuit or Wire Exposed. Do not touch exposed junctions and components when the unit is powered. Do Not Operate With Suspected Problems. If you suspect damage has occurred to this instrument, have it inspected by qualified service personnel before further operation. Any maintenance, adjustment or replacement, especially to the circuits or accessories should be performed by SIGLENT authorized personnel. Keep Product Surfaces Clean and Dry. Do Not Operate in Wet/Damp Conditions. To avoid electric shock, do not operate the instrument in wet or damp conditions. Do Not Operate in an...

Open the catalog to page 5
SIGLENT/oscilloscope/SDS2000X/service manual - 9

General Features SIGLENT’s SDS2000X series Super Phosphor Oscilloscopes are available in bandwidths of 70 MHz, 100 MHz, 200 MHz and 300 MHz, utilize a maximum sample rate of 2 GSa/s and a maximum record length of 140 Mpts. The most commonly used functions can be accessed with its user-friendly one-button design. The SDS2000X series employs a new generation of SPO technology. It employs an innovative digital trigger system with high sensitivity and low jitter. The maximum waveform capture rate is 140,000 wfm/s (normal mode) and up to 500,000 wfm/s (sequence mode). It also employs not only...

Open the catalog to page 9
SIGLENT/oscilloscope/SDS2000X/service manual - 10

• 70 MHz, 100 MHz, 200 MHz, 300 MHz models • Real-time sampling rate up to 2 GSa/s • New generation of SPO technology Waveform capture rate up to 140,000 wfm/s (normal mode), and 500,000 wfm/s (sequence mode) Supports 256-level intensity grading and color temperature display Record length up to 140 Mpts Digital trigger system • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern and Video (HDTV supported) • Serial bus triggering and decode, supports protocols IIC, SPI, UART, RS232, CAN, LIN • Low background noise, supports 1 mV / div to 10 V / div voltage...

Open the catalog to page 10
SIGLENT/oscilloscope/SDS2000X/service manual - 11

Large 8 inch TFT-LCD display with 800 * 480 resolution. Multiple interfaces, including USB Host, USB Device (USBTMC), LAN (VXI-11), Pass / Fail, Trigger Out Supports SCPI remote control commands Supports Multi-language display and embedded online help

Open the catalog to page 11
SIGLENT/oscilloscope/SDS2000X/service manual - 12

Prepare Information Before initiating performance verification or any adjustments, it is recommended the user follow these procedures. The following topics are discussed in this chapter.  How to perform functional checks How to operate four standard interface tests How to recall factory Default settings For more detailed information about oscilloscope operation, please refer to the Quick Start Guide. Functional checking The functional checking details three types of checks used to determine if the oscilloscope is operating properly. Power-on Inspection The normal operating voltage for the...

Open the catalog to page 12
SIGLENT/oscilloscope/SDS2000X/service manual - 13

Figure 1 Connect power cord Note: To avoid electric shock, make sure that the instrument is correctly grounded to the earth before connecting AC power. Press the power-on button located at the lower left corner of the front panel and note that several oscilloscope keys will be lighted for about 6 seconds simultaneously, until the boot screen appears. The oscilloscope will then begin to perform its power-on tests automatically, after which the DEFAULT SETUP button can be pressed in order to recall the factory default settings.

Open the catalog to page 13
SIGLENT/oscilloscope/SDS2000X/service manual - 14

Probe Compensation It is necessary to compensate the probe at first use so as to properly match the probe to the oscilloscope‟s input channel. Non-compensated or poorly compensated probes may cause measurement inaccuracies or errors. The probe compensation steps are as follows: 1. Set the attenuation switch on the probe to 10X. Figure 2 Set the attenuation switch 2. Connect the alligator clip of the probe to the Ground Terminal on the front panel, and then use the probe to connect CH1 BNC input connector to the Compensation Signal Output Terminal. Compensation Terminal Ground Terminal 3....

Open the catalog to page 14
SIGLENT/oscilloscope/SDS2000X/service manual - 15

Press the Auto Setup) key to enable the waveform auto setting function. The oscilloscope will automatically adjust the horizontal time base, vertical scale and trigger mode according to the input signal to obtain an optimum waveform display. Table 2 Auto setting menu • The input signal frequency must be higher than 20 Hz, with the amplitude greater than 8 mV. • Select the channel with the lowest frequency when several channels are connected to signals.

Open the catalog to page 15
SIGLENT/oscilloscope/SDS2000X/service manual - 16

Self Calibration The self-calibration routine can quickly adjust the oscilloscope to perform at the optimum state in order to achieve the maximum accuracy. Self-calibration can be performed at any time, especially when a change in the ambient temperature of 5°C or more has occurred. Make certain that the oscilloscope has been warmed up or operated for more than 30 minutes before performing the self-calibration. Use the following steps to perform self calibration: 1. Disconnect all leads from all input channels. 2. Press the |Utility| button on the front panel, and then press the Do Self...