SDS1000X-E Series Digital Oscilloscope SDS1000X-E Series Digital Oscilloscope SDS1202X-E Product overview SIGLENT's new SDS1000X-E Series Super Phosphor Oscilloscope is available in one bandwidth, 200 MHz. It has a maximum sample rate of 1 GSa/s and a standard record length of 14 Mpts. For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design. The SDS1000X-E series employs a new generation of SPO (Super Phosphor Oscilloscope) technology that provides excellent signal fidelity and performance. The system noise is also lower than similar...

Open the catalog to page 2
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 3

SDS1000X-E Series Digital Oscilloscope Weight Without package 2.5 Kg; With package 3.5 Kg • 7-inch TFT-LCD display with 800 * 480 resolution • Most commonly used functions are accessible using 10 different one-button operation keys: Auto Setup, Default, Cursor, Measure, Roll, History, Persist, Clear Sweep, Zoom, Print

Open the catalog to page 3
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 4

SDS1000X-E Series Digital Oscilloscope Functions & Characteristics Record Length of Up to 14 Mpts Waveform Capture Rate Up to 400,000 wfm/s Using hardware-based Zoom technologies and a record length of up to With a waveform capture rate of up to 400,000 wfm/s (sequence mode), 14 Mpts, users are able to use a higher sampling rate to capture more of the oscilloscope can easily capture the unusual or low-probability events. the signal and then quickly zoom in to focus on the area of interest. 256-Level Intensity Grading and Color Temperature Display SPO display technology delivers fast refresh...

Open the catalog to page 4
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 5

SDS1000X-E Series Digital Oscilloscope History Waveforms (History) Mode and Gate and Zoom Measurement Segmented Acquisition (Sequence) Playback the latest triggered events using the history function. Through Gate and Zoom measurement, the user can specify an arbitrary Segmented memory zcquisition will store the waveform into multiple interval of waveform data analysis and statistics. This helps avoid (up to 80,000) memory segments, each segment will store triggered measurement errors that can be caused by invalid or extraneous data, waveforms and timestamp each frame. greatly enhancing the...

Open the catalog to page 5
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 6

SDS1000X-E Series Digital Oscilloscope Specification Acquire System Acquire SystemInput Vertical System Vertical System

Open the catalog to page 6
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 7

SDS1000X-E Series Digital Oscilloscope

Open the catalog to page 7
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 8

SDS1000X-E Series Digital Oscilloscope Pulse Trigger Pulse Trigger Video Trigger

Open the catalog to page 8
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 9

SDS1000X-E Series Digital Oscilloscope

Open the catalog to page 9
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 10

SDS1000X-E Series Digital Oscilloscope

Open the catalog to page 10
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 11

SDS1000X-E Series Digital Oscilloscope FFR Time from the first falling edge of channel A to the first rising edge of channel B FFF Time from the first falling edge of channel A to the first falling edge of channel B LRR Time from the first rising edge of channel A to the last rising edge of channel B LRF Time from the first rising edge of channel A to the last falling edge of channel B LFR Time from the first falling edge of channel A to the last rising edge of channel B LFF Time from the first falling edge of channel A...

Open the catalog to page 11
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 12

SDS1000X-E Series Digital Oscilloscope Math Function Math Function

Open the catalog to page 12
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 13

SDS1000X-E Series Digital Oscilloscope Probes and Accessories Probe Bandwidth: 100 KHz, Max. continuous current: 20 Arms, Peak current: 60 A CP4020 Switch Ratio: 50 mV/A, 5 mV/A, Accuracy: 50 mV/A (0.4 A-10 Apk) ±2%, 5 mV/A (1 A-60 Apk) ± 2%, 9 V battery source Bandwidth: 1 MHz, Max. continuous current: 50 Arms, Peak current: 140 A Switch Ratio: 500 mV/A, 50 mV/A Accuracy: 500 mV/A (20 mA -14 ApK ) ± 3% ± 20 mA , 50 mV/A (200 mA100 ApK) ± 4% ± 200 mA, 50 mV/A (100 A-140 ApK) ± 15% max, 9 V battery source Bandwidth: 150 KHz, Max. continuous current: 70 Arms, Peak current: 200 A Switch Ratio:...

Open the catalog to page 13
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 14

SDS1000X-E Series Digital Oscilloscope Bandwidth: 70 MHz, Differential Range: 1500 V (DC + Peak AC), 50 X/500 X Accuracy: ± 2%, DC 5 V/1 A USB adapter Bandwidth: 100 MHz, Differential Range: 1500 V (DC + Peak AC), 50 X/500 X , Accuracy: ± 2% DC 5 V/1 A USB adapter Differential Probe Bandwidth: 70 MHz, Differential Range: 7000 V (DC + Peak AC), 100 X/1000 X , Accuracy: ± 2%, DC 5 V/1 A USB adapter High Voltage Isolated front end ISFE Bandwidth: 40 MHz Differential Range: DC 10 KV, AC (rms): 7 KV (sine), AC (Vpp): 20 KV (Pulse) 1000 X Accuracy: <3% The USB Device interface allows a connection...

Open the catalog to page 14
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 15

SDS1000X-E Series Digital Oscilloscope Product Name SDS1000X-E Series Digital Oscilloscope SDS1202X-E 200 MHz Two Channels USB Cable -1 Standard Accessories Quick Start -1 Passive Probe -2 Certification -1 Power Cord -1 CD (Included User Manual and EasyScopeX software)-1 Isolated Front End ISFE Optional Accessories High Voltage Probe Current Probe Differential Probe

Open the catalog to page 15
SIGLENT/oscilloscope/SDS1000X-E/datasheet - 16

CSIGLGNT About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, isolated handheld oscilloscopes and other general purpose test instrumentation. Since its first oscilloscope, the ADS7000...