Catalog excerpts
614 Digits Q DCV ACV f02W Freq Scanner 04W Hisense Conti; Temp Fused on Rear Panel CAT I (1000V) CAT II (600V)
Open the catalog to page 1Main Function SS Basic Measurement Function • DC Voltage: 200 mV - 1000 V • DC Current: 200 |jA - 10 A • AC Voltage: True-RMS, 200 mV - 750 V • AC Current: True-RMS, 200 jA - 10 A • 2/4-Wire Resistance: 200Q - 100 MQ • Capacitance: 2 nF - 100 mF • Continuity Test: Range is fixed at 2 kQ • Diode Test: Adjustable range is 0 - 4V. • Frequency Measurement: 3 Hz - 1 MHz • Period Measurement: 1 js - 333.33 ms • Temperature: Support for TC and RTD sensors The SDM3065X is a 6 % digit digital (2,200,000 count) multimeter • Max, Min, Average, Standard Deviation,dBm/dB, Relative incorporating a...
Open the catalog to page 2Special Features ES Histogram • Probe Hold
Open the catalog to page 3DC Characteristics Accuracy ± (% of reading + % of range) [1] Test Current Or Burden Voltage [1] Specifications are for 90-minute warm-up and 100NPLC integration time. For integration time <100NPLC, add the appropriate "RMS Noise Adder" listed in the following table. [2] 10% over range on all ranges except DCV 1000V and DCI 10A range. [3] Relative to calibration standards. [4] For each additional volt over ± 500 V, add 0.03mV error. [5] For continuous current > 7A DC or 7A AC RMS, 30 seconds ON and 30 seconds OFF. [6] Specifications are for 4-wire resistance measurement or 2-wire...
Open the catalog to page 4[1] Typical value. -1dBFS, 1k Hz single tone. 100 us aperture time and auto zero off.
Open the catalog to page 5Accuracy ± (% of reading + % of range) [1]
Open the catalog to page 6Range TCAL °C T C A L °C T C A L °C coefficient [1] Specifications are for 90-minute warm-up, > 3Hz ac filter and sine wave input. [2] 10% over range on all ranges except ACV 750 V and ACI 10 A ranges. [3] Relative to calibration standards. [4] Specifications are for sine wave input >5% of range. For inputs within 1% and 5% of range and <50 kHz, add 0.1% of range additional error. For 50 kHz to 100k Hz, add 0.13% of range additional error. [5] ACV 750 range limited to 8x107 Volt-Hz. For input over 300V rms, add 0.7mV error for each additional volt. [6] For continuous...
Open the catalog to page 7Remarks: [1] Specifications are for 90 minutes warm-up and using REL operation. Additional errors may be caused by non-film capacitors. [2] Specifications are the 1% to 110% of range on 2nF range and 10% to 110% of range on all other ranges WWW.SIGLENT.COM
Open the catalog to page 8Function Probe Type Type Optimum 1 Year Temperature Remarks: [1] Specifications are for 90 minutes warm-up. Exclusive of sensor error. [2] Specification is for 4WR sensor measurement or 2WR measurement using REL operation. [3] Relative to cold junction temperature, accuracy is based on ITS-90. Built-in cold junction temperature refers to the temperature inside the banana jack and its accuracy is ± 2.5 °C . Measurement Rate Function Remarks: [1] 20 V range, 1k Hz input. [2] The measurement period changes with the capacitance under test.
Open the catalog to page 9Measuring Method and other Characteristics DC Voltage
Open the catalog to page 10Detect the power-line frequency automatically at power-on, 400Hz defaults to 50Hz Power Consumption 25VA max Other characteristics
Open the catalog to page 12About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, isolated handheld oscilloscopes and other general purpose test instrumentation. Since its first oscilloscope, the ADS7000 series, was...
Open the catalog to page 14All Siglent Technologies Co. catalogs and technical brochures
-
SDS6000A Series
21 Pages
-
SDS 7000A Series
21 Pages
-
SDL1000X Series
10 Pages
-
SSM5000A Series
15 Pages
-
Spectrum Analyzer Bandwidth
6 Pages
-
Siglent_Product Catalog 2016
48 Pages
-
Siglent Selection Guide 2016
10 Pages
-
Benefits of deep memory
3 Pages
-
SIGLENT Probes Datasheet
7 Pages
-
Siglent SDS2000X User Manual
197 Pages
-
Siglent SDS2000X Service Manual
59 Pages
-
Probe Data Sheet + Siglent
7 Pages
-
USB-GPIB User Manual_Siglent
13 Pages
-
ISFE User Manual
12 Pages
-
Siglent TrueArb Technology
9 Pages
-
SDS2000 VS DS2000A_EN_Siglent
10 Pages
-
SIGLENT SDS1000CFL
8 Pages
-
SIGLENT SHS800 Data Sheet
10 Pages