ISFE User Manual-1

Isolated Front End Module Max. Input VoltagesIsolated CH1 and CH2 ±600Vpk Bandwidths1MHz Max. Floating Voltage From isolated channel to earth ground 1000Vrms Between two isolated channel 2000Vrms

 Open the catalog to page 1
ISFE User Manual-4

供电线路 信号线缆

 Open the catalog to page 4
ISFE User Manual-7

E-mail:support@ siglent.com KKiJlfj^flWMIHSfllillB* http://www.siglent.com Copyright© by Siglent Technologies Co., Ltd. all rights reserved. Siglent is a regisrered trademark of Siglent Contents in this Manual are not allowed to copy, ectract and translate before being allowed by Siglent.

 Open the catalog to page 7
ISFE User Manual-8

• A accessory for oscilloscope, plug and play • Less than 1W power dissipation, USB power supply • 10OOVrms form each channel to earth gound, 2000Vrms between channels • Providing isolation from ground and isolation between channels allowing you to take floating measurements • Max Voltage form Channl to Earth Gound: 10OOVrms • Max Voltage Between Channels: 2000Vrms Safety Information: Read First Carefully read the following safety information before using To avoid electrical shock or fire: Ground the device to earth ground Before using, inspect voltage probes, test leads and accessories for mechanical...

 Open the catalog to page 8
ISFE User Manual-9

Do not operate in an explosive atmosphere. Safety Terms and Symbols Terms in this Manual. These terms may be appeared in this manual: DANGER: indicates an injury hazard that may immediately WARNING indicates an injury hazard that may not immediately happen. CAUTION: indicates a poteential damage to the instrument or other property might occur. The following symbols may appear on the product: Hazardous Protective Refer to the Double Voltage Earth Terminal instruction Insulated

 Open the catalog to page 9
ISFE User Manual-10

Read this part before you make any connection, to avoid electrical shock: Two input BNC jacks (black) have no exposed metal and are fully insulated to protect against electrical shock. This part can be connected with source through proper probes or wires. The output BNC jacks made of metal. While the device powered on, do not contact them. These parts are supposed to connect with scope. Power supply interface. This interface is used to power the Adjust the knob at the back side of the device, make the level

 Open the catalog to page 10
ISFE User Manual-11

This device is used to test high voltage that may cause electrical shock, please operate it follow the steps below. Ground the device to earth ground. Conect the device to scope and power on. Set the scope to 100mv/div(DC Coupling). Adjust the konb at the back side and make the level to zero. Connect the device, scope and source before powering them Don't contact any exposed metal while the electrical loops Make sure that the source, device and scope are powered off before disconnected. Siglent Technologies warrants each SIGLENT manufactured and sold product against defects in material and workmanshio...

 Open the catalog to page 11
ISFE User Manual-12

warranties, expressed or implied, including but not limited to any inplied warranty or merchantability, fitness, or adequacy for any particular purpose or use. SIGLENT shall not be liable for any special, incidental, or consequential damages, whether in contract or otherwise. The customer is responsible for the transportation and insurance charges for the return of products to theservice facility. If you need any technical support or other help, you can contact SIGLENT service department Add: 3/F, Building 4, Antongda industry area,3rd LiuXan Rd, Baona District, ShenZhen, China. E-mail:support@...