TRANSDUCERS & ISOLATORS www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers kWh Energy Meters Analogue Panel Meters Shunts Digital Bargraphs THETA M+ PROGRAMMABLE MULTI-FUNCTION TRANSDUCER Digital Multimeters Protection Relays Synchroscope Series Rotary Switches Power Supplies Test & Measurement SUBJECT TO CHANGE WITHOUT NOTICE This datasheet superseded all previous versions – please keep for future reference
Open the catalog to page 1Product Features: ^ Fast Response Time ^ Best In Class Accuracy ^ Compliance to International Safety standards THETA M+ Programmable Multi-function Transducer Application Theta M+ transducer is used to measure and convert parameters of a single-phase or three-phase AC system with unbalanced or balanced load into a proportional load independent DC current or DC voltage output signal. It also provide digital output which can be configured for energy pulse output or limit output or timer output. • Upto 4 Isolated Analog outputs • True RMS and THD measurement upto 31st Harmonics • Fast Response time...
Open the catalog to page 2Product Features: 4-in-1 programmable transducers Measurement parameters like voltage, current, power, frequency and many more can be configured to any analog or digital output. Digital output configurable to Pulse output, Limit output or timer output. Fast Response Time Analog Output response time is less than 300 msec. Measuring Input AC Voltage/Current input signal, sine wave or distorted wave form upto 31st Harmonics Measurement of instantaneous values of more than 50 quantities (Voltage, Current, Power (W, VAR, VA), Power Factor, Phase Angle, Frequency, System and Per Phase Demand, THD,...
Open the catalog to page 3sifam tinsley PRECISION INSTRUMENTATION # Technical SpecificationsMeasured Parameter O Please refer Table 1 for List of measured parameters. Issue 1.0 TRANSDUCERS & ISOLATORS 3
Open the catalog to page 4Accuracy of Analog Output as per Selected input Parameter( Acc. to IEC / EN 60688) Issue 1.0 TRANSDUCERS & ISOLATORS 4
Open the catalog to page 5Issue 1.0 TRANSDUCERS & ISOLATORS 5
Open the catalog to page 6Issue 1.0 TRANSDUCERS & ISOLATORS 6
Open the catalog to page 7Programming of transducer can be done in 2 ways • Programming Via Optional RS485(MODBUS) Communication. • Programming Via USB port at front of the Transducer using USB cable. The programming by this method can also be done without aux supply(power from USB). • For Programming the transducer by any of the above two methods configuration software can be used which is provided on CD along with transducer. Terminal Details: Electrical Networks 3 Phase 4 Wire Unbalanced Load 3 Phase 3 Wire Unbalanced Load 3 Phase 4 Wire Balanced Load Dimensions Details: 3 Phase 3 Wire Balanced Load U12 I1 3 Phase...
Open the catalog to page 8Measured Parameter System wise: Table 1
Open the catalog to page 9Measured Parameter System wise: Table 1 Voltage Input Un: (Phase/Phase-to-Phase) Current Input In: (onsite programmable) 1A/5A Supply Voltage: Output Type: 4 Analog Outputs and 2 Relays 2 Analog Outputs and 2 Relays 4 Analog Outputs With RS485 communication Without RS485 communication USB Communication: With USB communication Order Code Example: TT44- 3 Phase 100-600 VLL, 1A/5A, 85. 285V AC/DC, 2 Analog Outputs and 2 Relays, With Rs485 communication, USB communication. Issue 1.0 TRANSDUCERS & ISOLATORS
Open the catalog to page 10Contact Sifam Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree Essex CM7 2YW Tel: 01376 335271 Email: [email protected] www.sifamtinsley.co.uk TRANSDUCERS & ISOLATORS