ND31PLUS

ND31PLUS

ND31PLUS

Product catalog summary
Overview: The ND31PLUS Power Network Meter is a sophisticated device designed for measuring and monitoring power network parameters. It supports Ethernet Daisy Chain topology and offers communication via MQTT, BACnet/IP, or MODBUS TCP/IP protocols.
Key Specifications:
  • Measures 54 power network parameters, including harmonics up to the 63rd order in various system configurations.
  • Features a high accuracy class of 0.2S for active energy.
  • Equipped with a 3.5” TFT LCD display, configurable by the user.
  • Includes 14 predefined screens for intuitive operation and power consumption forecasting.
  • Supports archiving of up to 32 parameters in its 8 GB internal memory.
Communication and Interface:
  • Ethernet Daisy Chain with 2 x RJ45 ports for simplified wiring and system expansion.
  • Supports MODBUS TCP/IP, HTTP, FTP, MQTT, and BACnet/IP protocols.
  • Includes a web server, FTP server, DHCP client, and NTP server for remote data access.
Features:
  • Two configurable alarm outputs with supervisory relay mode.
  • Analog output for retransmission and two Pt100 inputs for temperature measurement.
  • RS-485 digital output supporting MODBUS protocol.
  • Programmable via free eCon software.
Technical Data:
  • Input types include Pt100 with a measuring range of -50 to 400°C.
  • Current and voltage measurement ranges are specified with high precision.
  • Supports various power and energy measurements with specified accuracy classes.
Safety and Compatibility:
  • Complies with electromagnetic compatibility standards EN 61000-6-2 and EN IEC 61326-1.
  • Isolation and overvoltage categories are defined according to EN 61010-1.
  • Operates under a wide range of environmental conditions.
Ordering Information: The ND31PLUS can be customized with different input voltages, supply options, and language settings. Additional quality inspections and certificates are available upon request.
See more

Catalog excerpts

ND31PLUS-1

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIoT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS -1-

 Open the catalog to page 1
ND31PLUS-2

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS FEATURES • Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. • Ethernet Daisy Chain Topology. • Programmable choice of communication protocols: MQTT, BACnet / IP lub MODBUS TCP/IP. • Modern and user-friendly BACnet/IP interface. • High accuracy class (0.2S for active energy). • Graphical color display: LCD 3.5’’ typu TFT, 640 x 480 pixels, fully configurable by a user. • 14 predefined...

 Open the catalog to page 2
ND31PLUS-3

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS MEASUREMENT AND VISUALIZATION OF POWER NETWORK PARAMETERS • • • • • • • • • • • • phase voltages: U1, U2, U3 phase-to-phase voltages: U12, U23, U31 phase currents I1, I2, I3 active phase powers: P1, P2, P3 reactive phase powers: Q1, Q2, Q3 apparent phase powers: S1, S2, S3 active power factors: PF1, PF2, PF3 reactive/active power factors: tgj1, tgj2, tgj3 active, reactive and apparent 3-phase power: P, Q, S mean 3-phase power factors: PF, tgj frequency f mean 3-phase voltage: US mean phase-to-phase...

 Open the catalog to page 3
ND31PLUS-4

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS MEASURING RANGE Measured value tr_I - Current transformer ratio = Transformer primary current / Current transformer secondary current tr_U - Voltage transformer ratio = Transformer primary voltage / Voltage transformer secondary voltage

 Open the catalog to page 4
ND31PLUS-5

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS EXTERNAL FEATURES Readout field graphic color display LCD TFT 3,5’’ , 640 x 480 pixels Overall dimensions Protection grade from frontal side: IP65 from terminal side: IP20 Input signal 0...0.1...1.2 In; 0.1…0.2...1.2 Un for current, voltage, PFi, tgji Power factor Preheating time Ambient temperature without condensation Operating position External magnetic field Short-term overload Admissible crest factor RATED OPERATING CONDITIONS Supply voltage Power consumption Additional error (in % of the...

 Open the catalog to page 5
ND31PLUS-6

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS DISPLAING OF MEASUREMENT PARAMETERS up to 10 programmable screens (8 parameters per page); ability to change color for all screens Available colors for digital indications: two screens dedicated to harmonics; indication of individual harmonic for voltages and currents (up to 51st); bargraph presentation for all harmonics with zoom function presentation in the form of analog meter view with min/max preview for display value and zoom function Contracted power representation (Max Demand) in W, kW...

 Open the catalog to page 6
ND31PLUS-7

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS easy to use and intuitive menu; information bar with status of: phase sequence, alarm outputs, temperature measurements, archiving and memory, Ethernet and RS-485 interfaces, time and date *- available depending on the ND31PLUS version METER CONFIGURATION WITH FREE eCON SOFTWARE ability to configure and update ND31 with free eCon software (via RS-485 or Ethernet interface) REMOTE READOUT OF PARAMETERS THROUG ETHERNET: WWW SERVER, FTP WEB server for remote reading of current measurement data; FTP...

 Open the catalog to page 7
ND31PLUS-8

POWER NETWORK METER WITH ETHERNET DAISY CHAIN AND MQTT (IIOT), BACNET/IP OR MODBUS TCP/IP PROTOCOLS ORDERING CODE Meter ND31PLUS 2 relays, 1 analog output (0–20 mA), 2 Pt100 inputs, RS485, dual-port Ethernet, internal file system memory. Input voltage (phase/phase-to-phase) Un: 3 x 57.7/100 V, 3 x 230/400 V Language Polish/English Acceptance tests without additional quality requirements with an extra quality inspection certificate with an extra calibration certificate acc.to customer’s request* Version standard custom-made* * only after agreeing with the manufacturer ORDERING EXAMPLE, the code...

 Open the catalog to page 8

All Sifam Tinsley catalogs and technical brochures

  1. PD8W

    2  Pages

  2. KD6

    5  Pages

  3. INSU 5DX+

    6  Pages

  4. RE11

    2  Pages

  5. AP35-3RJ12

    10  Pages

  6. PD24

    8  Pages

  7. CBCT

    10  Pages

  8. ELPR

    6  Pages

  9. TW-E Series

    3  Pages

  10. Omicron UVR

    4  Pages

  11. UNO NX

    9  Pages

  12. LTRP Series

    12  Pages

  13. Gamma 36

    9  Pages

  14. PD9

    2  Pages

  15. ND31

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.