![Sierra Instruments - logo](https://img.directindustry.com/images_di/logo-p/L31166.gif)
![video corpo](https://img.directindustry.com/media/ps/images/common/stand/video-icon.gif)
Catalog excerpts
![InnovaSonic®207i - 1](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_1m.jpg)
The Transit-Time Ultrasonic Flow Meters for Precise Liquid Flow Metering / BTU Measurement
Open the catalog to page 1![InnovaSonic®207i - 2](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_2m.jpg)
207i Energy Rate (Btu/s) 85.63 Net Total (Btu) 436748.71 05/14/17 03:06:56
Open the catalog to page 2![InnovaSonic®207i - 3](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_3m.jpg)
With skyrocketing energy costs, there has never been a better time to invest in the precise flow measurement required to maximize your heating and cooling system efficiency, meet regulations, and bring down costs. Designed, built and calibrated by Sierra for non-intrusive liquid flow metering, and optimized for thermal energy / BTU measurement, the Innova-Sonic® 207i transit-time ultrasonic flow meter is the ideal turnkey solution for building and district metering, and submetering. The Flow Engine Behind it All At the heart of every 207i is advanced digital signal processing to...
Open the catalog to page 3![InnovaSonic®207i - 4](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_4m.jpg)
With the InnovaSonic 207i's clamp-on sensors, there's no pipe cutting or expensive plumbing. The 207i features a large backlit display and dualfunction keypad with audible feedback. With its visual sensor spacing tool on the display (see photo in center), slightly move the sensors together or apart to position the indicator line between the “goal posts” and assure optimal signal strength. Easily connect the 207i to your building management system with Modbus or BACnet communications. With its robust stainless steel enclosure, permanently fasten the transducers to make it a hardened...
Open the catalog to page 4![InnovaSonic®207i - 5](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_5m.jpg)
WaterLoop World Class Calibration Designed by Sierra and located at our metrology headquarters in Monterey, California, Sierra's Water-Loop™ is among the world's most accurate liquid/gas calibration facilities. Rated at +/- 0.2% of reading, all calibrations follow the guidelines of ISO 17025 and are directly traceable to national standards such as NIST (US National Institute of Standards and Technology). Fully automated, once flow application data is programmed, calibration automation software manages all aspects of flow calibration testing. This results in high-speed time-aligned data...
Open the catalog to page 5![InnovaSonic®207i - 6](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_6m.jpg)
PERFORMANCE SPECIFICATIONS Fluids All acoustically conductive liquids with <5% solids or bubbles Quantities Measured Volumetric flow Totalized volumetric and mass flow Heat energy Totalized energy flow Density Speed Heat capacity Enthalpy Ambient temperature Inlet and outlet temperature via PT 100 or current inputs Pressure (optional) Reynold's number Pipe Size 2 to 236 inches (50 to 6000 mm) Accuracy Accuracy +/- 0.5% of reading from 0.16 to 40 ft/s (0.05 to 12 m/s) Repeatability +/- 0.15% of reading > 0.16 ft/s (0.05 m/s) Resolution 0.01 ft/s (0.00025 m/s) Response Time 150 ms measuring...
Open the catalog to page 6![InnovaSonic®207i - 7](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_7m.jpg)
PHYSICAL SPECIFICATIONS 207i Transmitter Wall Mount with Transducers and Clamp-On RTDs for Thermal BTU Transmitter Enclosure Wall-mounted, NEMA 4X (IP65) 316 stainless enclosure with five %-inch (19 mm) conduit holes pre-drilled across the bottom Transducers Clamp-on transducers: encapsulated design IP68 Standard cable length: 30 ft (9 m) Maximum cable length: 300 ft (90 m) Memkey for automatic detection of sensor characteristics Insertion transducers IP68 Transducer Mounting Methods Pipe straps Chain Pipe clamps Keypad 16 tactile keys with 14 dual-function keys, audible...
Open the catalog to page 7![InnovaSonic®207i - 8](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_8m.jpg)
207i OPTIMAL INSTALLATION LOCATIONS Optimal Transducer Installation Examples Transducer Installation For Pump Storage Tanks Check Valve Flow Good TRANSDUCER SPACING REQUIREMENTS V Mount Transmitter Wall Mount with Pictured Transducers and Clampon RTDs (strain reliefs not included) Side View Upstream Transducer Downstream Transducer Strain Reliefs Wall Mount Transmitter Electronics Transducer Spacing Top View Z Mount Side View Upstream Transducer Clamp-on Temperature Transducers Downstream Transducer Upstream & Downstream Ultrasonic Transducers Transducer Spacing Top View
Open the catalog to page 8![InnovaSonic®207i - 9](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_9m.jpg)
207i TRANSMITTER DIMENSIONS Front View 207i Transmitter Wall Mount 207i Transmitter Mounted With Transducers. Proudly designed, manufactured, and calibrated in the USA. Side View 207i Transmitter Wall Mount Bottom View 207i Transmitter Wall Mount Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.
Open the catalog to page 9![InnovaSonic®207i - 10](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_10m.jpg)
Clamp-on Transducers Notes: Transducer hazardous area classification: Ex d II BT4 All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request. Parts List - Standard Insertion Transducers Standard Insertion Transducer Display For Thermal Energy / BTU Readout Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.
Open the catalog to page 10![InnovaSonic®207i - 11](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_11m.jpg)
CLAMP-ON RTD DIMENSIONS Front View Clamp-on PT 100 RTD Side View Clamp-on PT 100 RTD Bottom View Clamp-on PT 100 RTD [13] 0.50 [25] 1.00 Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.
Open the catalog to page 11![InnovaSonic®207i - 12](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_12m.jpg)
RTDI INSERTION DIMENSIONS Front View Insertion PT 100 RTD Standard Nipple Union Assembled (Threads Engaged) [140] 5.5 Standard Wrench Allowance And Thread Allowance [44] 1.75 Thermowell Insertion Length [50.8] 2.00 Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.
Open the catalog to page 12![InnovaSonic®207i - 13](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_13m.jpg)
Parent Number Feature 7: Digital Communications Feature 8 Strain Reliefs Accessories (RTDs) Accessories (Mounting)
Open the catalog to page 13![InnovaSonic®207i - 14](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_14m.jpg)
Flexibility And Options. Learn About Our Rental Program. How To Apply For Rental • Visit http://sierrainstruments.com/rental • Email Rental@SierraInstruments.com Learn More
Open the catalog to page 14![InnovaSonic®207i - 16](https://img.directindustry.com/pdf/repository_di/31166/innovasonic-207i-728914_16m.jpg)
sierrainstruments.com NORTH AMERICA 5 Harris Court, Building L / Monterey, CA 93940 / USA 800.866.0200 / 831.373.0200 / fax 831.373.4402 EUROPE Bijlmansweid2 / 1934RE Egmond aan den Hoef / The Netherlands +31 72 5071400 / fx +31 72 5071401 A S I A - PAC I F I C Second Floor Building 5 / Senpu Industrial Park 25 Hangdu Road Hangtou Town / Pu Dong New District Shanghai, P.R. China Post Code 201316 +8621 5879 8521/22 / fx +8621 5879 8586
Open the catalog to page 16All Sierra Instruments catalogs and technical brochures
-
Multi-Trak™ Model 670S
4 Pages
-
RedySmartT
6 Pages
-
RedyCompact
6 Pages
-
BoilerTraK 620S-BT
4 Pages
-
InnovaMass
19 Pages
-
FloBox ™ Model 951/954
2 Pages
-
CalTrak XL
4 Pages
-
FlowTrak™
2 Pages
-
InnovaSonic®203
4 Pages
-
InnovaSonic®210i
4 Pages
-
Flow Totalizer
20 Pages
-
SmartVO™
8 Pages
-
InnovaSwitch™ Level Switch
4 Pages
-
SmartTrak 100HP
6 Pages
-
InnovaMass 240/241 Series
14 Pages
-
SmartTrak 50 Series Low Flow
4 Pages
-
SmartTrak 100
8 Pages
-
service-calibration
4 Pages
-
sierra-servicebrochure-usa
4 Pages
-
Full line product offering
4 Pages
-
Sierra Clean Energy Guide
23 Pages