video corpo

InnovaSonic®207i

InnovaSonic®207i
1 / 16 PagesView full catalog

InnovaSonic®207i

Product catalog summary
Overview: The InnovaSonic 207i is a transit-time ultrasonic flow meter designed for accurate liquid flow and thermal energy/BTU measurement. It is optimized for non-intrusive metering, suitable for building and district metering, and submetering.
Key Features:
  • Advanced digital signal processing for enhanced accuracy.
  • Raptor OS with a learning algorithm for precise calculations.
  • Real-time liquid density calculations for high accuracy.
  • Accuracy of +/- 0.5% from 0.16 to 40 ft/s (0.05 to 12 m/s).
  • Compatible with pipe sizes from 2 to 236 inches (50 to 6000 mm).
  • Clamp-on or insertion transducers for bi-directional measurement.
  • Optional temperature inputs for BTU measurement.
  • Durable stainless steel enclosure.
Applications: Ideal for managing energy costs with accurate thermal energy/BTU measurements, especially in heating or cooling processes.
Specifications:
  • Flow velocity range: 0.16 to 40 ft/s (0.05 to 12 m/s).
  • Transducer operating temperature: 14°F to 302°F (-10°C to 150°C).
  • Power supply: 100-240 VAC or 9-36 VDC.
  • Digital communications: RS-485, RS-232, USB, Modbus RTU, BACnet pending.
Software and Apps: Includes apps for meter tuning, energy measurement configuration, and calibration validation, such as MeterFit, EnergyPro, and ValidCal Diagnostics.
Calibration and Support: Sierra's WaterLoop facility offers calibration services with high accuracy and traceability. Global support is available with flow centers and experts in over 50 countries.
Installation and Maintenance: Easy installation with clamp-on sensors, no pipe cutting needed. Includes a visual sensor spacing tool and integrates with management systems via Modbus or BACnet.
Conclusion: The InnovaSonic 207i is a versatile and precise flow meter, providing advanced features and robust support for efficient energy management.
See more

Catalog excerpts

InnovaSonic®207i-1

The Transit-Time Ultrasonic Flow Meters for Precise Liquid Flow Metering / BTU Measurement

 Open the catalog to page 1
InnovaSonic®207i-2

207i Energy Rate (Btu/s) 85.63 Net Total (Btu) 436748.71 05/14/17 03:06:56

 Open the catalog to page 2
InnovaSonic®207i-3

With skyrocketing energy costs, there has never been a better time to invest in the precise flow measurement required to maximize your heating and cooling system efficiency, meet regulations, and bring down costs. Designed, built and calibrated by Sierra for non-intrusive liquid flow metering, and optimized for thermal energy / BTU measurement, the Innova-Sonic® 207i transit-time ultrasonic flow meter is the ideal turnkey solution for building and district metering, and submetering. The Flow Engine Behind it All At the heart of every 207i is advanced digital signal processing to enhance ultrasonic...

 Open the catalog to page 3
InnovaSonic®207i-4

With the InnovaSonic 207i's clamp-on sensors, there's no pipe cutting or expensive plumbing. The 207i features a large backlit display and dualfunction keypad with audible feedback. With its visual sensor spacing tool on the display (see photo in center), slightly move the sensors together or apart to position the indicator line between the “goal posts” and assure optimal signal strength. Easily connect the 207i to your building management system with Modbus or BACnet communications. With its robust stainless steel enclosure, permanently fasten the transducers to make it a hardened installation,...

 Open the catalog to page 4
InnovaSonic®207i-5

WaterLoop World Class Calibration Designed by Sierra and located at our metrology headquarters in Monterey, California, Sierra's Water-Loop™ is among the world's most accurate liquid/gas calibration facilities. Rated at +/- 0.2% of reading, all calibrations follow the guidelines of ISO 17025 and are directly traceable to national standards such as NIST (US National Institute of Standards and Technology). Fully automated, once flow application data is programmed, calibration automation software manages all aspects of flow calibration testing. This results in high-speed time-aligned data acquisition and...

 Open the catalog to page 5
InnovaSonic®207i-6

PERFORMANCE SPECIFICATIONS Fluids All acoustically conductive liquids with <5% solids or bubbles Quantities Measured Volumetric flow Totalized volumetric and mass flow Heat energy Totalized energy flow Density Speed Heat capacity Enthalpy Ambient temperature Inlet and outlet temperature via PT 100 or current inputs Pressure (optional) Reynold's number Pipe Size 2 to 236 inches (50 to 6000 mm) Accuracy Accuracy +/- 0.5% of reading from 0.16 to 40 ft/s (0.05 to 12 m/s) Repeatability +/- 0.15% of reading > 0.16 ft/s (0.05 m/s) Resolution 0.01 ft/s (0.00025 m/s) Response Time 150 ms measuring cycle...

 Open the catalog to page 6
InnovaSonic®207i-7

PHYSICAL SPECIFICATIONS 207i Transmitter Wall Mount with Transducers and Clamp-On RTDs for Thermal BTU Transmitter Enclosure Wall-mounted, NEMA 4X (IP65) 316 stainless enclosure with five %-inch (19 mm) conduit holes pre-drilled across the bottom Transducers Clamp-on transducers: encapsulated design IP68 Standard cable length: 30 ft (9 m) Maximum cable length: 300 ft (90 m) Memkey for automatic detection of sensor characteristics Insertion transducers IP68 Transducer Mounting Methods Pipe straps Chain Pipe clamps Keypad 16 tactile keys with 14 dual-function keys, audible feedback Display 160...

 Open the catalog to page 7
InnovaSonic®207i-8

207i OPTIMAL INSTALLATION LOCATIONS Optimal Transducer Installation Examples Transducer Installation For Pump Storage Tanks Check Valve Flow Good TRANSDUCER SPACING REQUIREMENTS V Mount Transmitter Wall Mount with Pictured Transducers and Clampon RTDs (strain reliefs not included) Side View Upstream Transducer Downstream Transducer Strain Reliefs Wall Mount Transmitter Electronics Transducer Spacing Top View Z Mount Side View Upstream Transducer Clamp-on Temperature Transducers Downstream Transducer Upstream & Downstream Ultrasonic Transducers Transducer Spacing Top View

 Open the catalog to page 8
InnovaSonic®207i-9

207i TRANSMITTER DIMENSIONS Front View 207i Transmitter Wall Mount 207i Transmitter Mounted With Transducers. Proudly designed, manufactured, and calibrated in the USA. Side View 207i Transmitter Wall Mount Bottom View 207i Transmitter Wall Mount Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.

 Open the catalog to page 9
InnovaSonic®207i-10

Clamp-on Transducers Notes: Transducer hazardous area classification: Ex d II BT4 All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request. Parts List - Standard Insertion Transducers Standard Insertion Transducer Display For Thermal Energy / BTU Readout Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.

 Open the catalog to page 10
InnovaSonic®207i-11

CLAMP-ON RTD DIMENSIONS Front View Clamp-on PT 100 RTD Side View Clamp-on PT 100 RTD Bottom View Clamp-on PT 100 RTD [13] 0.50 [25] 1.00 Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.

 Open the catalog to page 11
InnovaSonic®207i-12

RTDI INSERTION DIMENSIONS Front View Insertion PT 100 RTD Standard Nipple Union Assembled (Threads Engaged) [140] 5.5 Standard Wrench Allowance And Thread Allowance [44] 1.75 Thermowell Insertion Length [50.8] 2.00 Note: All dimensions are inches (+/-.25-inch significant value). Millimeters are in parenthenses. Certified drawings available on request.

 Open the catalog to page 12
InnovaSonic®207i-13

Parent Number Feature 7: Digital Communications Feature 8 Strain Reliefs Accessories (RTDs) Accessories (Mounting)

 Open the catalog to page 13
InnovaSonic®207i-14

Flexibility And Options. Learn About Our Rental Program. How To Apply For Rental • Visit http://sierrainstruments.com/rental • Email [email protected] Learn More

 Open the catalog to page 14
InnovaSonic®207i-16

sierrainstruments.com NORTH AMERICA 5 Harris Court, Building L / Monterey, CA 93940 / USA 800.866.0200 / 831.373.0200 / fax 831.373.4402 EUROPE Bijlmansweid2 / 1934RE Egmond aan den Hoef / The Netherlands +31 72 5071400 / fx +31 72 5071401 A S I A - PAC I F I C Second Floor Building 5 / Senpu Industrial Park 25 Hangdu Road Hangtou Town / Pu Dong New District Shanghai, P.R. China Post Code 201316 +8621 5879 8521/22 / fx +8621 5879 8586

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.