SITRANS FM (electromagnetic) Flow sensors
10Pages

{{requestButtons}}

Catalog excerpts

SITRANS FM (electromagnetic) Flow sensors - 1

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Integration The complete flowmeter consists of a sensor and an associated transmitter SITRANS FM MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems such as PROFIBUS DP and PA, Modbus RTU/RS 485, HART, FOUNDATION Fieldbus H1, DeviceNet. Pressure/temperature curve; material AISI 316L/1.4404 Pressure/temperature curve; material AISI 316L/1.4404 PN 40 Sensor sizes: DN 10 to DN 100 (3/8" to 4") AISI 316 stainless steel enclosure Sensor: Hygienic connection, 3A approval Sanitary design for CIP/SIP cleaning Easy commissioning, the SENSORPROM unit automatically updates settings • Hose proof IP67/NEMA 4X enclosure rating • Designed that patented in-situ verification can be conducted. Using SENSORPROM fingerprints. Pressure/temperature curve; material AISI 316L/1.4404 The main applications of the SITRANS FM electromagnetic sensors can be found in the following fields: • Food industry • Beverage industry • Pharmaceutical industry ■ Design • Unique mechanical design with a wide range of customer specified sanitary connection • Compact or remote mounting possible easy “plug & play” field changeable • Simple on site upgrade to IP68/NEMA 6P terminal box • ATEX 2G D version for hazardous areas (ceramic liner) ■ Mode of operation The flow measuring principle is based on Faraday’s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. Pressure/temperature curve; material AISI 316L/1.4404 The electromagnetic sensor SITRANS FM MAG 1100 F is designed to meet applications in the food and beverage industry.

Open the catalog to page 1
SITRANS FM (electromagnetic) Flow sensors - 2

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Technical specifications Measuring principle Electromagnetic induction Excitation frequency (Mains supply: 50 Hz/60 Hz) Stainless steel AISI 316L/1.4404 • Clamp fitting Terminal box (remote version only) • Standard • Option • Ex ATEX (remote version only) Fibre glass reinforced polyamide Stainless steel AISI 316/1.4436 Stainless steel AISI 316/1.4436 • Threaded fitting Process connection Nominal size Process connection Hygienic adapters available for: • Direct welding onto pipe Rated operating conditions Aluminum oxide...

Open the catalog to page 2
SITRANS FM (electromagnetic) Flow sensors - 3

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Technical specifications (continued) ■ Selection and ordering data Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Diameter DN 10 (3/8“) Thread adapter Clamp adapter Weld-in adapter Adapter for welding onto dairy pipe, stainless steel 1.4404 • DN 10, 15, 25, 40, 50 and 65 (3/8", ½", 1", 1½", 2" and 2½") • DN 8 and DN 100 (3" and 4") Process connections None (not suitable for 3A approval) Clamp type Stainless steel AISI 316/1.4436 FKM/FPM with stainless steel insert (AISI 304/1.4301)...

Open the catalog to page 3
SITRANS FM (electromagnetic) Flow sensors - 4

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Selection and ordering data Operating instructions for SITRANS FM MAG 1100 F Click on the Article No. for the online configuration in the PIA Life Cycle Portal. All literature is available to download for free, in a range of languages, at https://www.siemens.com/processinstrumentation/documentation Communication No communication, add-on possible PROFIBUS PA Profile 3 (only MAG 6000/MAG 6000 I) PROFIBUS DP Profile 3 (not for Ex) (only MAG 6000/MAG 6000 I) Modbus RTU/RS 485 (not for Ex) (only MAG 6000/MAG 6000 I)...

Open the catalog to page 4
SITRANS FM (electromagnetic) Flow sensors - 5

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Selection and ordering data Accessories for MAG 1100 F sensor Weld-in connection fittings for use with P gaskets (Stainless steel) Material: AISI 316L (1.4404) Only for liner PFA 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Material: AISI 316L (1.4404) Only for liner PFA 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Clamp-type connection fittings for use with P gaskets (Stainless steel)

Open the catalog to page 5
SITRANS FM (electromagnetic) Flow sensors - 6

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Selection and ordering data Threaded type connection fittings for use with P gaskets (Stainless steel) Weld-in connection fittings for use with flat gaskets (Stainless steel) Material: AISI 316L (1.4404) Only for liner PFA 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Material: AISI 316L (1.4404) For liner PFA and ceramic 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), Flat gaskets not included

Open the catalog to page 6
SITRANS FM (electromagnetic) Flow sensors - 7

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Selection and ordering data Clamp-type connection fittings for use with flat gaskets (Stainless steel) Threaded type connection fittings for use with flat gaskets (Stainless steel) Material: AISI 316L (1.4404) For liner PFA and ceramic 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), Flat gaskets not included Material: AISI 316L (1.4404) For liner PFA and ceramic 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), Flat gaskets not included Do: Outer diameter Di: Inner diameter 1)

Open the catalog to page 7
SITRANS FM (electromagnetic) Flow sensors - 8

Flow Measurement SITRANS FM (electromagnetic) Flow sensors MAG 1100 F ■ Selection and ordering data Spare parts for MAG 1100 F sensor Gaskets (delivered in pairs, to be placed between flow sensor and adapter) MAG 1100 F (PFA) - P gaskets Rubber: EPDM • DN 10 • DN 15 • DN 25 • DN 40 • DN 50 • DN 65 • DN 80 • DN 100 MAG 1100 F (ceramic) - Flat gaskets Rubber: FKM/FPM • DN 10 • DN 15 • DN 25 • DN 40 • DN 50 • DN 65 • DN 80 • DN 100 MAG 1100 F (PFA, ceramic) - Flat gaskets Rubber: EPDM • DN 10 • DN 15 • DN 25 • DN 40 • DN 50 • DN 65 • DN 80 • DN 100

Open the catalog to page 8