Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated
20Pages

{{requestButtons}}

Catalog excerpts

Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 1

Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated Medium-Voltage Switchgear

Open the catalog to page 1
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 2

Circuit-Breaker Switchgear Type 8BT2 · Siemens HA 26.41 · 2019

Open the catalog to page 2
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 3

Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated Medium-Voltage Switchgear Catalog HA 26.41 • 2019 Invalid: Catalog HA 26.41 ■ 2016 siemens.com/8bt2 Application Page Customer benefits and features 5 Technical Data Electrical data, dimensions 6 Product Range Compartments, operation, interlocks 13 The products and systems described in this catalog are manufactured and sold according to a certified management system (acc. to ISO 9001, ISO 14001 and BS OHSAS 18001). Circuit-Breaker Switchgear Type 8BT2 ■ Siemens HA 26.41 ■ 2019

Open the catalog to page 3
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 4

Application Typical uses Typical uses The 8BT2 circuit-breaker switchgear is used in transformer and switching substations, mainly at the primary distribution level, e.g.: Application: Industry • Power stations • Cement industry • Iron and steel works • Rolling mills • Mining industry • Textile, paper and food industries • Chemical industry • Petroleum industry • Pipeline installations • Electrochemical plants • Diesel power plants • Emergency power supply installations • Traction power supplies • Airports • Wind parks. Circuit-Breaker Switchgear Type 8BT

Open the catalog to page 4
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 5

Customer benefits • Peace of mind For power supply companies and industrial plants, the certification of the 8BT2 according to the latest standards has very concrete advantages: Smooth operation, exemplary availability and maximum safety. - Factory-assembled, type-tested switchgear according to IEC 62271-200 - More than 510,000 air-insulated switchgear panels from Siemens in operation worldwide - Use of maintenance-free vacuum circuit-breakers - Use of standard, worldwide available components - Quality management according to DIN EN ISO 9001 - As insulating medium, air is always available;...

Open the catalog to page 5
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 6

Front view 1) Closed pressure relief duct is only available in FLR panels. Circuit-Breaker Switchgear Type 8BT2 ■ Siemens HA 26.41 ■ 2019

Open the catalog to page 6
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 7

Type of pressure relief Single-row arrangement (plan view) 1) For panel replacement, wall-standing > 2750 mm For panel replacement, free-standing > 3000 mm 2) If smaller distances are required, please consult PLM 3) For wall-standing panels, both ends must be closed due to backward pressure relief from connection compartment in the event of internal arc fault. To prevent rear access to switchgear, the factory provides rear cover plates (standard: 200 mm depth) to close both ends. 4) For free-standing application only Circuit-Breaker Switchgear Type 8BT2 ■ Siemens HA 26.41 ■ 2019

Open the catalog to page 7
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 8

Product Range Panels Circuit-breaker panel Disconnecting panel Metering panel Components Current transformer Make-proof earthing switch Cable sealing ends max. 6 x 500 mm2 per phase Current transformer in run of busbar Disconnector link Withdrawable circuit-breaker Voltage transformer Capacitive voltage detecting system Withdrawable voltage transformer with primary fuses *) This version can only be selected for free-standing application. Circuit-Breaker Switchgear Type 8BT2 · Siemens HA 26.41 · 2019

Open the catalog to page 8
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 9

Product Range Bus sectionalizer (mirror-image installation also possible) Withdrawable panel Busbar connection panel Components Current transformer Capactive voltage detecting system Withdrawable voltage transformer with primary fuses Voltage transformer Withdrawable circuit-breaker Withdrawable voltage transformer Make-proof earthing switch Cable sealing ends max. 6 x 500 mm2 per phase Circuit-Breaker Switchgear Type 8BT2 · Siemens HA 26.41 · 2019

Open the catalog to page 9
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 10

Design Classification Circuit-breaker switchgear type 8BT2 is a factory-assembled, type-tested, metal-enclosed and metal-clad switchgear for indoor installation according to IEC 62271-200.Classification. The 8BT2 switchgear corresponds to the following classifications according to IEC 62271-200 8BT2 switchgear is suitable for unrestricted application (wall or free-standing arrangement) in electrical service locations up to the maximum short-circuit ratings. Circuit-Breaker Switchgear Type 8BT2 ■ Siemens HA 26.41 ■ 2019

Open the catalog to page 10
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 11

Panel design 1 Door of low-voltage compartment 2 Protection device 3 Option: Capacitive voltage detecting system for feeder and busbar 4 Mimic diagram 5 High-voltage door 6 Inspection window for checking the switching device truck 7 Opening for locking and unlocking the high-voltage door 8 Door handle 9 Opening for manual (ON/OFF) operation of the circuit-breaker 10 Inspection window for reading the indicators located on the circuit-breaker 11 Opening for earthing switch operation 12 Openings for switching device truck operation 13 Pressure relief flaps 14 Busbars 15 Bushings 16 Block-type...

Open the catalog to page 11
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 12

Panel design 13 Pressure relief flaps 14 Busbars 15 Bushings 16 Block-type current transformer 18 Earthing switch 17 Withdrawable voltage transformer with primary fuses 19 Cable sealing ends 20 Cable bracket 22 Vacuum interrupters 23 Contact system 24 Switching-device truck 5 Voltage transformer 2 26 Earthing busbar 19 20 Free-standing, width: 1200 mm, depth: 2700 mm, fixed type VT in CC Free-standing, width: 1200 mm, depth: 2700 mm, withdrawable VT with primary fuses in CC Circuit-Breaker Switchgear Type 8BT2 · Siemens HA 26.41 · 2019 A Switching-device compartment B Busbar compartment C...

Open the catalog to page 12
Circuit-Breaker Switchgear Type 8BT2 up to 36 kV, 31.5 kA, Air-Insulated - 13

Compartments, operation, interlocks Switching-device compartment • All switching operations with high-voltage door closed • Pressure relief upwards • Panel powder-coated with epoxy resin • Metallic, earthed shutters ensure partition class PM • High-voltage door pressure-resistant in the event of internal arcs in the panel • Metallic ducts on the side for laying control cables • Interlocking between high-voltage door and circuit-breaker truck ensures interlock-controlled access • Switching-device compartment to accommodate components for implementing various panel versions with - Vacuum...

Open the catalog to page 13

All Siemens Medium-voltage – Power distribution catalogs and technical brochures

  1. E-House