Overview: The FC801-AA is a fire control panel designed for railway applications, centralizing fire information and managing fire devices and protection on trains. It is approved for Safety Integrity Level 2 and interfaces with train management systems via Ethernet or dry contact.
Specifications: The panel supports a loop of up to 32 FDOOT801 multi-sensor fire detectors and can be configured with up to 8 fire detection zones and 16 protection zones. It features a compact, rack-mountable design (3U, 24TE) and operates on a nominal train voltage of DC 72V to DC 110V.
System Configuration: The FC801 can be adapted to specific customer requirements using the Configuration Management Tool (FXS8002), allowing customization of detection and protection zones and alarm strategies. It supports both trailer and consist train architectures.
Functional Elements: The panel includes 3 visible LEDs for status indication (Power, Alarm, Fault, Warning) and various connectors for FDOOT801 devices, Ethernet, power supply, and safety dry contacts. It provides 4 monitored inputs for Linear Heat Detectors or Manual Call Points.
Technical Data: The panel operates within a temperature range of -25°C to +70°C and is compliant with railway standards EN 50155, EN 50126, EN 50128, EN 50129, and EN 45545-2. It is housed in colorless anodized aluminum with IP31 front protection.
Approvals: The system is certified by Certifer for SIL2 with FDOOT801 devices.
Ordering Information: The FC801-AA fire control panel is designated with part number S54449-C101-A1.
See more

Catalog excerpts

Fire - Panels & Systems-1

Fire control panel for Railway • Centralize Fire Information and Manage Fire Devices and Fire Protection of the Train • Approved Safety Integrity Level 2 • Ethernet and/or dry contact interface to the train management system (TCMS) • Ethernet interface to the Configuration Management Tool (CMT) • Microprocessor-controlled panel for the connection of one loop of up to 32 FDOOT801 Multi-sensor Fire Detectors. • Railway compact, rack mountable equipment (3U, 24TE) • Configurable Fire Panel with auto-addressable loop • Configuration with up to 8 fire detection zones and up to 16 protection zones • Centralized System with simplified cabling (daisy chain loop). • Flexible and easy system configuration with enhanced combination for train platforms flexibility • Rearmament, Protection Inhibition, Test functions controlled through train lines inputs • Power supply output for one complete loop of 32 FDOOT801 • 4x Inputs for Linear Heat Detector, or Manual Call Point • 3x Safety Fire Detection Dry Contacts outputs (Warning, Alarm, Fault,) • 1x Safety Fire Protection Dry Contacts output Building Technologies

 Open the catalog to page 1
Fire - Panels & Systems-2

System overview The FC801 control panel can be configured to fit one of the two following train architectures: Trailer architecture (one System per car) Consist Architecture (one System for several cars)

 Open the catalog to page 2
Fire - Panels & Systems-3

Configurable System size - Up to 32 FDOOT801 devices (smoke or T° detector) Up to 68 Fire Peripherals inputs (LHD, HD, Manual Call Point,..) Up to 33 Fire Protection Outputs (lights, sounders, extinguishing devices …) Up to 32 Fire protection zone Inputs monitoring / inhibition Up to 8 Fire Detection Zones Up to 16 Fire Protection Zones The Configuration Management Tool FXS8002 permits the system to be adapted to specific customers' requirements. It allows to mainly configure the links between: - detection inputs with detection zones, - protection outputs with protection zones, - detection zones...

 Open the catalog to page 3
Fire - Panels & Systems-4

FC801 is a compact fire control panel that can process signals from FDOOT801 devices and from its own inputs. It provides 4 monitored inputs for connection of LHD (Linear Heat Detector), or Manual Call Point (MCP). It centralizes Fire Events with synthetic safety I/O indications: - System Fire Alarm: - 1 ALARM dry contact for Fire Alarm Indication (safety output) - 8 dry contacts for Fire Alarm Zones Indication - System Monitoring: - 1 FAULT dry contact for System Failure Indication (Inoperative System) - 1 WARNING dry contact for Component Failure Indication (Degraded performance mode) It provides...

 Open the catalog to page 4
Fire - Panels & Systems-5

Technical data Main voltage Power supply voltage for FDOOT801 Connectable detector series Number of lines – Can bus loop – Configuration and Maintenance – Train communication Number of looped addressing devices Integrated inputs/outputs – Fire Safety Relay Output – Alarm – Fault – Warning – Fire Safety Protection Relay Output – Monitored Inputs (LHD, HD or MCP inputs) – Zones indication discrete Outputs – Train line discrete Inputs – INH (Inhibition) – Rearm (Rearmament) – Test Man interface unit Operating temperature Storage temperature Weight Color 1700 g colorless anodized aluminum Compliance...