1. Catalogs
  2. Siemens Fire Safety
  3. FC1002, FC1004 Control units

FC1002, FC1004 Control units

FC1002, FC1004 Control units

FC1002, FC1004 Control units

Product catalog summary
Overview: The Siemens FC1002 and FC1004 are conventional fire alarm control units designed for 2 or 4 zones. They are compatible with all conventional Siemens detectors and offer flexibility with features like programmable alarm organization, cross-zoning, and non-latching zone options for non-fire events.
Specifications:
  • 2 or 4 zones with compatibility for various Siemens detectors.
  • Selectable detector line standards for broad compatibility.
  • Monitored control lines for sirens and strobe lights.
  • Programmable alarm settings for different operational modes.
  • Integral emergency power capacity up to 72 hours with a 7.2 Ah battery.
System Features:
  • Detection lines can be programmed for current limited or non-current limited operation.
  • Support for intrinsically safe detectors in hazardous areas.
  • Dry contacts for general alarm and fault notifications.
  • Monitored control lines for external devices like horns and flashlights.
  • Fire control relays rated at 10 A/250 V.
Country Variants:
  • FC1002/04-B: British Standard variant with special detection circuit monitoring.
  • FC1002/04-C: Nordic variant with a fire authority key switch.
  • FC1004-E: Dutch variant with additional evacuation control line.
Technical Data:
  • Supply voltage: AC 115/230 V, 50/60 Hz.
  • Power consumption: 13 to 25 VA.
  • Operating temperature: 0 to +50 °C.
  • Storage temperature: -20 to +60 °C.
  • Humidity: Up to 95% relative humidity at 25 °C.
  • Dimensions: 370 x 286 x 90 mm.
  • Protection category: IP40.
  • Standards: EN 54-2, EN 54-4.
Accessories:
  • Relay module Z3B171 for fire control installations.
  • Battery FB2003-A1, a gas-tight lead battery 12 V/7.2 Ah.
  • RT-isolation card FCA1005-D for remote transmission channels.
  • Key switch FCA1007 for operating access.
Ordering Information: The document provides part numbers and weights for different control unit types and accessories, with language options for inscription stripes.
See more

Catalog excerpts

FC1002, FC1004 Control units-1

• Compatible with all conventional Siemens detectors • 2 selectable detector line standards for a wide range of detector compatibility • 2 monitored control lines for sirens, strobe lights etc. • Programmable alarm organization for manned/unmanned operation • Alarm verification • Suitable to collect non-fire related events with non-latching zone option • Simple user controls with isolate/test button per zone • Key code user access with optional key switch alternative • Easy on-site configuration • Integral capacity for emergency power of up to 72 h Fire & Security Products Siemens Building Technologies

 Open the catalog to page 1
FC1002, FC1004 Control units-2

System overview Detector line AlgoRex DS110x Detector line Synova 600 (non-current limited) Monitored control lines for - horns, sirens - beacons Detector line Synova 300 (current limited) Fire controls - internal relays Detector line Synova 300 with line continuity according to BS 5839 Pt1 FC10 Remote transmission - internal contact Call point line Mixed line (detector/call point with differentiation) EX-area Intrinsically safe detectors SB3 Linear smoke detector or flame detector Series MS6/7/9 Non-fire alarm (technical alarm) EOL Detector line termination with two different types, depending...

 Open the catalog to page 2
FC1002, FC1004 Control units-3

Simple “out of the box” start up with preset default values Country variants FC1002/04-B For British Standard (BS) market. Incorporates special detection circuit end-of-line monitoring which on removal of a detector will indicate a fault on the control unit but still allow devices fitted beyond the removed detector to function. Each detector base must be fitted with a continuity diode. FC1002/04-C For Nordic Countries. This unit comes fitted as standard with a Nordic fire authority key switch. FC1004-E For Dutch Market. Incorporates additional evacuation control line and integral evacuation function....

 Open the catalog to page 3
FC1002, FC1004 Control units-4

Technical Data Supply voltage Power consumption Quiescent current FC1002-A/-B/-C FC1004-A/-B/-C/-E Emergency power operating Outputs Dry contact Alarm Dry contact Fault Fire control relays (optional, 1…2) monitored control lines (2) Driver outputs (5 or 7) Control inputs (3) Operating temperature Storage temperature Humidity (no condensation permitted) at T = 25 ±3 °C at T = 40 ±2 °C Cabinet Dimensions (W x H x D) Color cover FC10xx-A/-B/-C/-E Protection category (IEC 60529) Standards AC 115/230 V, +10 %/–15 %, 50/60 Hz 13 ... 25 VA 80 mA 90 mA … 72 h 30 V/1 A, NO/NC 30 V/1 A, NO/NC 250 V/10...

 Open the catalog to page 4