SIPROTEC 7SJ85 Feeder and overcurrent protection
1 /2Pages

SIPROTEC 7SJ85 Feeder and overcurrent protection

SIPROTEC 7SJ85 Feeder and overcurrent protection
1 /2Pages

Catalog excerpts

SIPROTEC 7SJ85 Feeder and overcurrent protection-1

Description The SIPROTEC 7SJ85 overcurrent protection has been designed specifically for the protection of feeders and lines. With its modular structure, flexibility, and the high-performance DIGSI 5 engineering tool, the SIPROTEC 7SJ85 device offers futureoriented solutions for protection, control, automation, monitoring, and Power Quality - Basic.. Main function Feeder and overcurrent protection for all voltage levels Inputs and out- 5 predefined standard variants with 4 puts current transformers, 4 voltage trans formers, 11 to 59 binary inputs, 9 to 33 binary outputs Hardware flexibi- Flexibly adjustable and expandable I/O lity quantity structure within the scope of the modular SIPROTEC 5 system; 1/6 expansion modules can be added, available with large or small display, or without display Housing width 1/3 x 19 inch to 2/1 x 19inch Applications • Detection and selective 3-pole tripping of short circuits in electrical equipment of star networks, lines with infeed at 1 or 2 ends, parallel lines, and open-circuited or closed ring systems of all voltage levels up to AC 400 V • Backup protection for differential protection devices of all kind for lines, transformers, generators, motors, and busbars • Protection and monitoring of capacitor banks • Phasor Measurement Unit (PMU) • Reverse-power protection • Load shedding applications • Automatic switchover • Regulation or control of power transformers (two- winding transformers, three-winding transformers, grid coupling transformers) Feeder and overcurrent protection SIPROTEC 7SJ85 (housing width 1/3 x 19'' to 2/1 x 19'') • Detection and recording of power-quality data in the mediumvoltage and subordinate low-voltage power system Functions DIGSI 5 permits all functions to be configured and combined as required. • Directional and non-directional overcurrent protection with additional functions • Protection of up to 9 feeders with up to 40 analog inputs • Optimized tripping times due to directional comparison and protection data communication • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground-fault function, cos 0, sin 0, dir. detection of intermittent ground faults, harmonic detection, and admittance measurement • Arc protection • Ground fault detection using the pulse detection method • Detection of intermittent ground faults with automatic blocking of statically measuring functions to avoid message and fault-record flooding • Arc pro

 Open the catalog to page 1
SIPROTEC 7SJ85 Feeder and overcurrent protection-2

• Fault locator plus for accurate fault location with in-homogenous line sections and targeted automatic overhead-line section reclosing (AREC) • Overvoltage and undervoltage protection • Power protection, configurable as active or reactive-power protection • Frequency protection and frequency-change protection for load-shedding applications • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration • Protection functions for capacitor banks, such as overcurrent, overload, current-unbalance, peak overvoltage,...

 Open the catalog to page 2

All SIEMENS Energy automation and smart grid catalogs and technical brochures

  1. SIPROTEC Compact

    220  Pages

  2. SICAM Q100

    28  Pages

  3. 7SR5 Platform

    86  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.