SIPROTEC 7SA87

SIPROTEC 7SA87

SIPROTEC 7SA87

Product catalog summary
Description
The SIPROTEC 7SA87 is a distance protection device designed for line protection. It features a modular structure and uses the DIGSI 5 engineering tool for protection, control, automation, monitoring, and basic power quality functions.

Main Function
The primary function is distance protection, with interoperability between SIPROTEC 4 and 5 devices. It supports 1-pole and 3-pole tripping with a minimum tripping time of 9 ms.

Inputs and Outputs
The device offers 12 predefined standard variants with various configurations of current and voltage transformers, binary inputs, and outputs.

Hardware Flexibility
The I/O quantity structure is adjustable within the SIPROTEC 5 modular system.

Applications
  • Detection and selective tripping of short circuits in various network configurations.
  • Ground fault detection in isolated or arc-suppression-coil ground systems.
  • Serial protection communication over different distances and media.
  • Backup protection for differential protection devices.
  • Phasor Measurement Unit (PMU) and power-quality data recording.

Functions
  • Configurable functions via DIGSI 5.
  • Multiple distance-protection functions including classic, reactance method, and impedance protection.
  • Ground fault detection using various methods.
  • Adaptive power-swing blocking and out-of-step protection.
  • Current-transformer saturation detection for fast tripping.

Additional Features
  • Fault locator for accurate fault location.
  • Arc protection and automatic frequency relief.
  • Power protection configurable as active or reactive-power protection.
  • Detection of harmonics up to the 50th harmonic.
  • 1-pole automatic reclosing with secondary arc detection.
  • Graphical logic editor for automation functions.
  • Integrated Ethernet interface and optional communication modules.
  • Extensive cybersecurity features including role-based access control and secure web access.
  • High-performance fault recording and time synchronization.

Benefits
  • Enhanced safety with powerful protection functions.
  • User-friendly design for easy handling.
  • Compliance with cybersecurity standards.
  • High availability under extreme conditions.
  • Compatibility with IEC 61850 Editions 1, 2.0, and 2.1.
See more

Catalog excerpts

SIPROTEC 7SA87-1

Description+ The SIPROTEC 7SA87 distance protection has been designed specifically for the protection of lines. With its modular structure, flexibility and the high-performance DIGSI 5 engineering tool, the SIPROTEC 7SA87 device offers future-oriented solutions for protection, control, automation, monitoring, and Power Quality- Basic. Main function Distance Protection Interoperability of SIPROTEC 4 and SIPROTEC 5 line protection devices Tripping 1-pole and 3-pole, minimum tripping Inputs and out- 12 predefined standard variants with 4/4 puts or 8/8 current transformers/voltage trans formers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibi- Flexibly adjustable I/O quantity structure lity within the scope of the SIPROTEC 5 modu Housing width 1/3 x 19 inch to 2/1 x 19 inch Applications • Detection and selective 1 -pole and 3-pole tripping of short circuits in electrical equipment of star networks, lines with infeed at one or 2 ends, parallel lines, and open-circuited or closed ring systems of all voltage levels • Detection of ground faults in isolated or arc-suppres-sion-coilground systems in star, ring, or meshed arrangement • Serial protection communication with SIPROTEC 5 and SIPROTEC 4 devices over different distances and physical media, such as optical fiber, two-wire connections, and communication networks • Backup protection for differential protection devices of all kind for lines, transformers, generators, motors, and busbars • Phasor Measurement Unit (PMU) • Detection and recording of power-quality data in the mediumvoltage and subordinate low-voltage power system Functions DIGSI 5 permits all functions to be configured and combined as required. • Minimum tripping time: 9 ms • 6 independent measuring loops (6-system distance protection) • Several distance-protection functions can be selected: Classic, reactance method (RMD), impedance protection for transformers • Directional backup protection and various additional functions • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos 0, sin 0, dir. detection of intermittent ground faults, harmonic detection, and admittance measurement • Ground-fault detection using the pulse-detection method • Adaptive power-swing blocking, out-of-step protection • Detection of current-transformer saturation for fast tripping with high accurac

 Open the catalog to page 1
SIPROTEC 7SA87-2

• Fault locator plus for accurate fault location with in-homogenous line sections and targeted automatic overhead-line section reclosing (AREC) • Arc protection • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration • Power protection, configurable as active or reactive-power protection • Directional reactive-power undervoltage protection (QU protection) • Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload...