Open the catalog to page 1Contents Editorial _________________________________________________________________________________________________________ 3 Devices and Fields of Application __________________________________________________________________________________ 4 1.1 Main Protection _________________________________________________________________________________________ 4 1.1.1 7SR10/7SR105 _______________________________________________________________________________________4 1.1.1.1 7SR10 Non-Directional Overcurrent Protection Relay ___________________________________________________4 1.1.1.2 7SR105...
Open the catalog to page 3Since 1886, when Mr A.C Reyrolle established a small work shop in London, the Reyrolle brand has been prominent at all stages of the power supply chain from generation to large end-users. We design and manufacture relays for the world wide protection and control market. We are committed to high technology development and manufacture with full use of the latest software at all stages of product development, manufacture and testing. This can be seen in the latest digital products that Reyrolle offer. With over 100 years of proven innovative technology and many industry firsts, we are very...
Open the catalog to page 4Devices and Fields of Application 1.1.1.1 7SR10 Non-Directional Overcurrent Protection Relay 81 THD Total Harmonic Distortion Supervision Control 79 Auto Reclose Features Cold Load Settings Two Settings Groups Password Protection - 2 levels User Programmable Logic Self Monitoring Circuit Breaker Trip and Maintenance Counter Trip Timers The 7SR10 overcurrent and earth fault relay is developed by using the latest generation of hardware technology and is available in multiple variants depending on power supply, Binary input/binary output configuration and data communication facility. 7SR10 is...
Open the catalog to page 5Fault Records Waveform Records Measurands Commands Time Synchronism Viewing and Changing Settings 49 Thermal Overload The thermal algorithm calculates the thermal states from the measured currents and can be applied to lines, cables and transformers. Alarm outputs are given for thermal overload and thermal capacity. Application The 7SR10 overcurrent and earth fault relay is a numerical overcurrent protection relay intended for use in the distribution and industrial networks. It provides a highly comprehensive functional software package with a range of integral application functions aimed...
Open the catalog to page 674T/CCS Trip and Close Circuit Supervision The trip or close circuit(s) can be monitored via binary inputs. Trip circuit failure raises an HMI alarm and output(s). 81HBL2 Inrush Restraint Where second harmonic current is detected (i.e. during transformer energisation) user selectable elements can be blocked and an alarm given. 81THD Total Harmonic Distortion Supervision Total harmonic distortion is the percentage of harmonics present in fundamental frequency current. THD calculates the 2nd to 15th harmonic currents presents inline current and displayed in the ‘Harmonic Meter’ window as a...
Open the catalog to page 7The function provides independent phase fault and earth fault/sensitive earth fault sequences of up to 5 trip i.e. 4 reclose attempts before lockout. An auto-reclose sequence can be user set to be initiated from internal protection operation or via binary input from an external protection. Data Acquisition Via Communication Interface RS485 Screened twisted pair Rear terminals RS485 Screened twisted pair Ext Wire loop to Include line terminating Res Rear terminals Fig 4. Typical RS485 connection Sequence of Event Records Up to 1000 events are stored and time tagged to 1 ms resolution. Fault...
Open the catalog to page 8User Interface Technical Data Fig 5. User Interface The operator interface is designed to provide a user friendly method of controlling, viewing menus, entering settings, and retrieving data from the relay. Five buttons are provided for navigation around the menu structure. Two dedicated push buttons are provided on the HMI to execute the CB manual close and open operations. LCD A 4 line by 20 character liquid crystal display with power save operation indicates the relay identifier, settings, instrumentation, fault data and control commands. Up to 6 user programmable general alarms can be...
Open the catalog to page 9Current Inputs Siemens Protection Devices Limited 9 Refer to Ordering Information for more details. For more details about binary inputs, refer to Technical Manual.
Open the catalog to page 10Electrical Tests Climatic Environmental Tests Test Siemens Protection Devices Limited 10 NOTE: 45 ms DTL pick-up delay applied to binary inputs # NOTE: All aspect of IEC 60255-5 have been covered under IEC 60255-27
Open the catalog to page 11Siemens Protection Devices Limited
Open the catalog to page 12Siemens Protection Devices Limited 12
Open the catalog to page 13Case Dimensions Fig 8. Panel cut-out view Siemens Protection Devices Limited
Open the catalog to page 14III III! Ill llll llll llll 11 xi Fig 10. Terminal/Wiring Diagram View (Extended Version) Siemens Protection Devices Limited 14
Open the catalog to page 15Product Description Variants Nondirectional O/C Relay (Argus) Case, I/O and Fascia Size 4 Moulded case, 4 CT, 3 Binary Inputs/3 Binary Outputs, 10 LEDs Size 4 Moulded case, 4CT, 6 Binary Inputs/6 Binary Outputs, 10 LEDs Measuring input 1/5 A, 50/60Hz 1) 1/5 A, 50/60Hz with SEF input 2) Auxiliary voltage AC/DC 60-240V, Binary input threshold 44 V AC/VDC AC/DC 60-240V, Binary input threshold 88 V AC/VDC DC 24-60 V, Binary input threshold 19 VDC Protective Cover Standard version - No Cover Plastic Cover with 1 Push Button for Test/Reset Communication Front Port : USB Front Port : USB and Rear...
Open the catalog to page 161.1.1.2 7SR105 Motor Protection Relay Control 86 Lockout Motor Start/Stop Control User Programmable Logic Features Two Settings Groups Password Protection - 2 levels User Programmable Logic Self Monitoring Circuit Breaker Trip and Maintenance Counter Trip Timers 20 Character x 4 Line Backlit LCD Menu Navigation Keys 9 User Programmable Tri-colour LEDs Dedicated motor start and stop push buttons Primary/Secondary Current Phases and Earth Positive Phase Sequence (PPS) Current Negative Phase Sequence (NPS) Current Zero Phase Sequence (ZPS) Current Thermal equivalent and unbalanced currents...
Open the catalog to page 17All SIEMENS Energy automation and smart grid catalogs and technical brochures
-
7SR5 Platform
86 Pages
-
Reyrolle 7SR54
2 Pages
-
Reyrolle 7SR51
2 Pages
-
SICAM Q100
2 Pages
-
7SR17 Rho Motor Protection Relay
20 Pages
-
7SR21 & 7SR22 Argus
2 Pages
-
SIPROTEC 7SA87
2 Pages
-
SIPROTEC 7SA86
2 Pages
-
SIPROTEC 7SA82
2 Pages
-
SICAM A8000 Series
11 Pages
-
SICAM Substation Automation
190 Pages
-
Reyrolle 5 Platform
52 Pages
-
SIPROTEC Compact
210 Pages
-
Catalog SICAM CMIC
8 Pages
-
7SC80 Brochure
8 Pages
-
Catalog - Bay Controller
32 Pages