Reyrolle Protection Devices! 7SR158 Argus Voltage and Frequency Relay Energy Management
Open the catalog to page 1Siemens Protection Devices Limited
Open the catalog to page 2Voltage & Frequency Relay 20 Character x 4 Line Backlit LCD Menu Navigation Keys 9 User Programmable Tri-colour LEDs Primary/Secondary Line and Phase Voltages Positive Phase Sequence (PPS) Voltage Negative Phase Sequence (NPS) Voltage Zero Phase Sequence (ZPS) Voltage Frequency Binary Input/Output status Time and date Starters Fault data Event records CB trip and maintenance counters and Time to Trip The 7SR158 is a voltage and frequency protection relay developed to enhance the Argus family of products by providing a familiar device using the latest generation of hardware technology....
Open the catalog to page 3Negative Phase Sequence Voltage Neutral Voltage Displacement Vector Shift Under/Over Frequency Rate of Change of Frequency FUNCTIONAL REQUIREMENT Function Matrix CT/VT CONFIG > Phase Voltage Config: Van,Vbn,Vcn Trip & Close Circuit Supervision CT/VT CONFIG > Phase Voltage Config: Va,Vb,Vc CT/VT CONFIG > Phase Voltage Config: Van,Vbn,Vcn, or Vab,Vbc,3V0 Va * Not all versions - see Function Matrix CT/VT CONFIG > Phase Voltage Config: Va,Vb,Vc Siemens Protection Devices Limited CT/VT CONFIG > Phase Voltage Config: Vab,Vbc,3V0
Open the catalog to page 4Description of Functionality With reference to figure 2 ‘Function Diagrams’. 27/59 Under/Over Voltage Each element has settings for pickup level, drop-off level and Definite Time Lag (DTL) delay. Operates when voltage exceeds setting for the duration of delay. 47 Negative Phase Sequence Voltage Each element has settings for pickup level and Definite Time Lag (DTL) delays. Operates when NPS voltage exceeds setting for the duration of delay. 59N Neutral Overvoltage Neutral overvoltage can be used to detect earth faults in high impedance earthed or isolated systems. Operates when neutral...
Open the catalog to page 5Data Acquisition Via Communication Interface Sequence of event records Up to 1000 events are stored and time tagged to 1ms resolution. Fault Records The last 10 fault records are displayed on the relay fascia and are also available through the communication interface, with time and date of trip, measured quantities and type of fault. Waveform recorder The waveform recorder stores analogue data for all poles and the states of protection functions, binary inputs, LEDs and binary outputs with user settable pre & post trigger data. A record can be triggered from protection function, binary...
Open the catalog to page 6Reydisp Evolution Communications Editor To facilitate interfacing to a substation the relay default Protocol configuration may be modified using the communication editor software tool. The communication editor is a PC based software package provided within the Reydisp software suite which allows modification of the IEC60870-5-103, DNP 3.0 and MODBUS Protocols. kJpM. H«*. W~to. OW.HW.B t&iit mw Fig.6 Typical Reydisp Evolution Screenshot Reydisp Manager Reydisp Evolution is common to the entire range of Reyrolle numeric products. The user can apply settings, interrogate settings, retrieve...
Open the catalog to page 7User Interface The relay is housed in a 4U high size E4 or E6 case with a removable clear plastic fascia cover. The plastic fascia cover can be ordered with or without two push buttons to allow the user to view the settings and instruments without removing the cover. Two plastic handles are provided to allow the relay to be withdrawn from its case, contacts in the case ensure that the normally closed contacts remain short circuited when the relay is withdrawn. The rear terminal blocks comprise M4 female terminals for ring crimp wire connections, to provide a secure and reliable termination....
Open the catalog to page 8For full technical data refer to the Performance Specification Section of the Technical Manual. Voltage Inputs Operating Voltage 19V dc DC Range 17 to 320V dc AC Range 92 to 138 VrmsAC 88V dc Range 70 to 320V dc Maximum dc 1.5mA current for operation Maximum peak ac 1.5mA current for operation Pick Up Delay User Selectable 0 to 14,400,000ms (up to 4 hours) Drop Off Delay User Selectable 0 to 14,400,000ms (up to 4 hours) For AC operation the BI pick-up delay should be set to 0ms and the drop-off delay to 20ms. Siemens Protection Devices Limited 9
Open the catalog to page 9Mechanical Tests Data Communication Interface Communication Port Vibration (Sinusoidal) IEC 60255-21-1 Class I Shock and Bump IEC 60255-21-2 Class I EN100 Fibre Optic Data Communication Interface (IEC 61850 Option) Data Storage Fault Record 10 Siemens Protection Devices Limited 10
Open the catalog to page 10Type Level Between any terminal and earth Between independent circuits Across normally open contacts Radiated Radio Frequency IEC 60255-25 Conducted Radio Frequency Radiated Immunity IEC 60255-22-3 Class III High Frequency Disturbance IEC 60255-22-1 Class III Siemens Protection Devices Limited 11
Open the catalog to page 11Siemens Protection Devices Limite
Open the catalog to page 12Case Dimensions Case Earth connection Typical when fitted SIDE VIEW FRONT VIEW 25mm MIN CLEARANCE FOR TERMINAL WIRING Fig.12 E4 Case overall dimensions and panel drilling details (all dimensions are in mm) PANEL CUT-OUT Typical when fitted SIDE VIEW Case Earth connection MINIMUM CLEARANCES: 25mm FOR TERMINAL WIRING 75mm FOR ETHERNET COMMS MODULE Diameter 3.6 - 4 holes (see note) FRONT VIEW FRONT NOTE: THE 3.6 HOLES ARE FOR M4 THREAD FORMING (TRILOBULAR) SCREWS. THESE ARE SUPPLIED AS STANDARD AND ARE SUITABLE FOR USE IN FERROUS / ALUMINIUM PANELS 1.6mm THICK AND ABOVE. FOR OTHER PANELS,...
Open the catalog to page 13See Relay Voltage Config. Setting Ethernet Data Comms (optional) NOTES BI = Binary Input, BO = Binary Output Shows contacts internal to relay case assembly. Contacts close when relay chassis withdrawn from case Siemens Protection Devices Limited
Open the catalog to page 14Ordering Information – 7SR1587 Product description Voltage/frequency relay Protect Product Family Voltage Relay Type Voltage & Frequency Case, I/O and Fascia E4 case, 3 VT, 6 Binary Inputs / 8 Binary Outputs, 10 LEDs Measuring input 40 to 160 V, 50/60Hz Auxiliary voltage 80 to 250 V DC / 115 V AC, binary input threshold 19 V DC 80 to 250 V DC binary input threshold 88 V DC 24 to 60 V DC, binary input threshold 19 V DC Spare Communication Interface Standard version – included in all models, USB front port, RS485 rear port (E6 Case) 1) Standard version - plus additional rear electrical...
Open the catalog to page 15All SIEMENS Energy automation and smart grid catalogs and technical brochures
-
7SR5 Platform
86 Pages
-
Reyrolle 7SR54
2 Pages
-
Reyrolle 7SR51
2 Pages
-
SICAM Q100
2 Pages
-
7SR17 Rho Motor Protection Relay
20 Pages
-
7SR21 & 7SR22 Argus
2 Pages
-
SIPROTEC 7SA87
2 Pages
-
SIPROTEC 7SA86
2 Pages
-
SIPROTEC 7SA82
2 Pages
-
SICAM A8000 Series
11 Pages
-
SICAM Substation Automation
190 Pages
-
Reyrolle Product Catalogue
346 Pages
-
Reyrolle 5 Platform
52 Pages
-
SIPROTEC Compact
210 Pages
-
Catalog SICAM CMIC
8 Pages
-
7SC80 Brochure
8 Pages
-
Catalog - Bay Controller
32 Pages