Synova product catalog
204Pages

{{requestButtons}}

Catalog excerpts

Synova product catalog - 1

Building Technologies Group International Headquarters The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Subject to change • Order no. 0-92085-en • © Siemens Switzerland Ltd • Printed in Switzerland • 10707 Synova™ product catalog. Fire protection products

Open the catalog to page 1
Synova product catalog - 2

Whatever your requirements, Siemens provides a comprehensive portfolio for all fire safety and security needs.

Open the catalog to page 2
Synova product catalog - 3

© Siemens Buildinn Technoloaies GrouD

Open the catalog to page 3
Synova product catalog - 4

© Siemens Buildinn Technoloaies GrouD

Open the catalog to page 4
Synova product catalog - 5

© Siemens Ruildino Technolonies GrouD 3

Open the catalog to page 5
Synova product catalog - 6

fire detectors from " Backed by 5iemens' more than 150 years of experience in fire detection, Synova™ is both extremely sensitive and reliable. Thermo sensors react to slow and fast temperature changes and are immune to deception. Optical smoke detectors incorporate a patented chamber design for a wide response range and an exceptional immunity to dust and dirt. This is what we understand by an innovative solution ensuring protection against the dangers of fire - whatever the area of application may be. For more information, please visit www.siemens.com/synova Building Technologies

Open the catalog to page 6
Synova product catalog - 7

Synova Installation Guidelines Wuh this seclion we would like to share best practice on installation lor fire deteclion equip- ment. The hints grven may not cover all possi- ble cases, but give guidelines for the installa- tion. Local regulations may be mere detaited. Please contaci your local Fire Safety & Security Products sales organization from Siemens for mere detailed information and documentation. Synova™ detectors Detectors should be placed - at least 0.5 m from a wall Synova™ manual call points Manual call points (MCP) should be placed - clearly visible - ai i .5 rn from floor...

Open the catalog to page 7
Synova product catalog - 8

Synova Installation Guidelines I-2 © Siemens Building Technologies Group

Open the catalog to page 8
Synova product catalog - 9

Synova Installation Guidelines Place the detector at the highest point in Keep the correct distance to ceiling Keep a minimum distance to objects vuhirh ITI IL] lit rovíír thfi view Ir, ;Ì m^nu:il C^ll point. Manual call points should not be obscured © Siemens Building Technologies Group

Open the catalog to page 9
Synova product catalog - 10

System Compatibility Chart Conventional devices Heal defedare Manual call points Special deiecTore IIHE module; poni iriJMi © Siemens Building Technologies Group

Open the catalog to page 10
Synova product catalog - 11

System Compatibility Chart © Siemens Building Technologies Group

Open the catalog to page 11
Synova product catalog - 12

Synova Installation Guidelines Monitoring area per smoke detector The monitoring area (Aj^) ÍE determined as a function of room height and the fire danger little file danger 3 mator fire danger Monitoring area per smoke detectar as a function of room height and degras of danger. Degree of danger level 2 can be chosen for most applications. Degree of danger level 1 should only be chosen: - If all danger to life can be excluded. - If no valuable or irreplaceable articles are stared in the room concerned. - If other fire protection measures would virtually preclude fire spread. - If no smoking...

Open the catalog to page 12
Synova product catalog - 13

Genesis Senes (1-zone Panels) Safety for people and assets. Our Genesis Series stands for comprehensive safety. In combination with an intrusion control panel, it is the professional solution for reliable fire detection. As your existing network infrastructure can be used for instal- lation, you will prof it from low investment costs. Based on an intrusion detection control panel, Genesis 2 enables the instal- lation of a single-zone fire detection system. It also controls and supervises a 2-wire line, equipped with up to 32 conventional detectors. Supplied with 12 VDC from the intrusion...

Open the catalog to page 13
Synova product catalog - 14

Conventional Control Panels Genesis Series Fire control panel for connection to 12 VDC supply The Genesis 2 makes it possible to install single zone fire detection based on a conventional intrusion detection control panel, controlling and supervising a 2-wire line, equipped with up to 32 conventional The Genesis 2 is supplied with 13.8 VDC from the intrusion control pan- el and, by means of an internal converter, is able to provide the 24 VDC supply required by the detectors and/or call points. This eliminates the need for an external 24 VDC power supply and battery backup, as in the case...

Open the catalog to page 14
Synova product catalog - 15

Conventional Control Panels Genesis Series Fire control panel for connection to 12 VDC supply As GEN2.. for technical details, but with the following differences: Dutch language printed on the product. Fire control panel for connection to 12 VDC supply As GEN2.. for technical details, but with the following differences: Spanish language printed on the product. Fire control panel PCB for all languages As GEN2.. for technical specification but without housing. © Siemens Building Technologies Group

Open the catalog to page 15
Synova product catalog - 16

Conventional Fire Control Panels Conventional System Overview FC1D conventional fire control panel ■ 2 - 24 zones for the connection of the conventional SynoLIMESQO or collective SynoLlNE600 tines ■ Brigade Delay Concept (alarm verification) ■ ton lalch zones (e,g. for technical alarm) ■ Remote 'Acknowledge" and "Reset" functions ■ Differentiation of alarm from "manual call point" and "automatic detector" alarm on the same line ■ Password or key switch secured operation ■ Keypad and LED displays for mains/battery monitoring, alarms, faults, remote transmission, isolation, signal...

Open the catalog to page 16
Synova product catalog - 17

Conventional Fire Control Panels The new FC10 series sets the new standard in functionality and design for conventional fire detection panels. FC1002 is an easy-to-handle, cost-effective fire detection panel that is ideal for small installations. Each line can be individually configured to SynoLINE300 and SynoLINE600. This allows to connect all Synova™ conventional detec- tors as well as special detectors like DF1191 flame, DL01191 linear Conventional line Transmission output contact Supervised output Control output Control input Mains voltage Power consumption Quiescent current Battery...

Open the catalog to page 17