BC80 system catalog
28Pages

{{requestButtons}}

Catalog excerpts

BC80 system catalog - 1

BC80 system catalog. Building Technologies 1

Open the catalog to page 1
BC80 system catalog - 2

A wide range of applications. BC80 comprises an extensive product portfolio and can be installed in various building types. For instance, it is a perfect solution for: Hotels Government buildings 2 Commercial buildings Residential complexes Retail stores

Open the catalog to page 2
BC80 system catalog - 3

High-quality Siemens Your customers are responsible for the protec- tion of their employees, buildings, and assets. They also experience cost competition. As a result, they need fire protection components that deliver reliable fire detection and alarm signaling, but which are also cost-efficient. Fire safety products from Siemens position you per- fectly to satisfy your customers' requirements. The BC80 system products range from fire detec- tors to control panels. They are moderately priced and of reliable quality. ■ Siemens quality - high reliability With the BC80 system, you can offer...

Open the catalog to page 3
BC80 system catalog - 4

Easy concepts make your work easier. BC80 fire protection products are easy to imple- ment and service. They can be quickly installed and rapidly commissioned. This reduces your costs and speeds up order processing. Simplicity of design reduces the period needed to gain familiarity with the system, so you can offer your customers user-friendly fire protection in the shortest possible time. fast protection Because the BC80 system units have been designed for easy installation, buildings can be protected quickly. BC80 provides polarity-free wiring; poles can no longer be accidentally...

Open the catalog to page 4
BC80 system catalog - 5

Easy expandability - high flexibility BC80 grows with your customers' requirements. When buildings or stallation can also be expanded, for example with new T-Branches in the cabling and expansion cards in the control panels. With an expansion card it is possible to hook up an additional 1 27 periph- eral devices via the F-Bus, as many as 32 additional control panels via the A-Bus, and up to three B-Bus devices, such as extinguishing control panels or interlocking panels. This increases options for larger projects. Easy conversion - fast modernization Existing systems can be replaced and...

Open the catalog to page 5
BC80 system catalog - 6

installation guidelines. In this section, we illustrate best practice for installation of fire detection equipment. While not all possible cases may be covered, these are intended to provide guidelines. Local regulations may be more detailed and must always be ob- served. Please contact your local Siemens sales organization for more detailed information and ■ at least 0.5 m from the wall BC80 manual call points - manual call points should ■ in a clearly visible location ■ 1.5 m from floor level BC80 fire control panels - mounting the fire control Keep a minimum distance to objects which...

Open the catalog to page 6
BC80 system catalog - 7

Detector positioning near elevators* Detector positioning near detector at ceiling height* * or observe local regulations

Open the catalog to page 7
BC80 system catalog - 8

installation guidelines. highest point in the room* Ensure the correct distance Position the detector within Ensure a minimum distance to objects which could ob- struct the view to a manual call point* Manual call points should * or observe local regulations

Open the catalog to page 8
BC80 system catalog - 10

BC80 at a glance. Compact A-Bus Compact controller BC8001 F-Bus Manual call point BDS121/e Output module BDS221 Compact controller BC8001 Input module BDS132 Manual call point BDS121/e Interlocking panel BT8011 10 Collective input module BDS161 Heat detector BDS031 Collective heat detector HI520 Photoelectric smoke detector BDS051 Interlocking panel BT8012

Open the catalog to page 10
BC80 system catalog - 11

Standard Standard control panel BC8002 Collective photoelectric smoke detector OP520 F-Bus Standard control panel BC8002 Extinguishing panel BC8013 B-Bus Legend A-Bus Network for connecting control panels (max. 32 control panels, bus length 1 km – can be extended with CAN-Bus bridge) F-Bus Bus system for connecting line devices (max. 127 devices per line, bus length 1 km) B-Bus Network for connecting up to 3 B-Bus devices (bus length 100 m) 11

Open the catalog to page 11
BC80 system catalog - 12

your protection. BC80 - Innovative fire safety products from Siemens. Are you seeking reliable and easy to use fire safety products everywhere? With the addressable BC80, Siemens offers an extensive and economical portfolio from fire detectors to control panels. Thanks to its open topology, BC80 is highly flexible and adapts easily to changing requirements. The perfect solution for a wide range of applications from small to large buildings, it can be quickly installed, networked, and put into service. Backed by 150 years of experience in fire protection, BC80 offers the effective protection...

Open the catalog to page 12
BC80 system catalog - 13

1) Siemens Building Technologies Group 1

Open the catalog to page 13
BC80 system catalog - 15

Panels & Systems Addressable Control Panels BC8001 Compact Control Unit BC8001 is a control unit suitable for small sized projects and construc- tions. It has the following features: i Compatible to BDS series of field devices. i Features a polarity free F-BUS with a twisted pair of wires (Osi .5mm2). Transmission distance is up to 1000m. All devices should be evenly distributed. i Specialized BDS Algorithm enhance immunity against environment i Menu driven man-machine interface to allow very easy operation. 1 With optional extension card the device can be networked with up to 32 other BC80...

Open the catalog to page 15
BC80 system catalog - 16

Panels & Systems Addressable Control Panels BC8001E Compact Control Unit with 2 F-Bus lines for up to 254 As BC8001.. for technical details, but with the following differences: An extension card is built-in additionally in the BC8001. This allows i Interconnection of up to 32 BC8001 or BC8002 control units (A-Bus). i Interconnection of up to 3 B-BUS equipments (BT8011/12 interlock- ing panel, BC8013 extinguishing panel). Another external power supply (3 A @ 28 VDC) must be used. BC8001 PE Compact Control Unit with 2 F-Bus lines and printer As BC8001.. for technical details, but with the...

Open the catalog to page 16
BC80 system catalog - 17

Panels & Systems Addressable Control Panels BC8002-2 wall-mounted Advanced Control Unit for up to 1000 As BC8002.. for technical details, but with the following differences: The fire alarm control unit with an additional line card can connect up to 1000 devices, using 8 loops BC8002-3 wall-mounted Advanced Control Unit forvi 500 devices A6C50000030 As BC8002.. for technical details, but with the following differences: The fire alarm control unit with 3 line cards can connect up to 1500 devices, using 12 loops BT8011 / BT8012 are interlocking panels. It allows manual and auto- matic control...

Open the catalog to page 17

All Siemens Building Technology HVAC Products catalogs and technical brochures

  1. WFx3

    2 Pages

  2. QBE

    6 Pages

  3. GCA

    6 Pages

  4. 2WR6..

    14 Pages

  5. WHE5.. WHE6

    14 Pages

Archived catalogs