modular series PXC...-E.D • Freely programmable modular automation stations for HVAC and building services plants. • Communications - BACnet/IP - BACnet/LonTalk • BTL label (BACnet communications is BTL tested) • Comprehensive management and system functions (alarm management, time schedules, trends, access protection, etc.) • Connection of TX-I/O modules with any data point mix • Connection of TX Open modules for the integration of third-party devices • Integration of LoNMARK®-compatible devices • Integrated web server for generic operaion • For stand-alone applications, or for use within a device or system network • Scalable range of touch panels and operating devices Validity This data sheet is valid for firmware Desigo V6.1 and higher. For older devices / firmware see data sheet CM1N9222en 13. Building Technologies
Open the catalog to page 1Modular, freely programmable automation stations for HVAC and building control systems. • Management functions (alarm management with alarm routing, schedulers, trend functions, remote management, access protection with individually defined user profiles and categories). • For stand-alone applications or for use within a device or system network. • BTL-tested BACnet communications on LonTalk, PTP or IP, compliant with BACnet standard (Rev. 1.12 -for Desigo V6.0 and later) including B-BC profile. • AMEV profiles AS-A and AS-B to recommendation "BACnet 2011 - Version 1.2 (for Desigo V6.0 and later)"....
Open the catalog to page 2Extension capabilities of the automation stations TXM1.. : The flexible range of TX-I/O modules for signaling, measuring, counting, switching, and positioning. The I/O modules with local manual control on the module housing permit the operator to control the equipment manually directly from the cabinet. 2) A high number of LonWorks devices reduces the performance of the PXC for connected TX-I/O or PTM-I/O data points respectively. Siemens Building Technologies
Open the catalog to page 3PXX-PBUS : The extension module allows connecting installed PTM-I/O modules to PXC50/100/200...D automation stations, making them the perfect solution to migrate legacy systems. Device combinations with the automation stations Adapter for Firmware download Siemens Building Technologies
Open the catalog to page 4Siemens Building Technologies
Open the catalog to page 5Battery change 1) If one of the batteries has low charge the "BAT" LED lights up ant the automation station sends a system event. Remaining battery life after a "Low batt" event: • Battery for real time clock (Type CR2032): several days. • Battery for trend data and present parameters (Type AA Lithium): approx. 15 hrs. Alkaline: several days. • As long as there is an external power supply, the battery may be removed for unlimited time. • To prevent hardware damage by electrostatic discharge (ESD), a wrist strap with earth cable must be used during the battery change. • Note the special disposal...
Open the catalog to page 6Technical data General device data Operating voltage Safety extra-low voltage SELV or Extra-low voltage PELV Operating frequency Energy consumption Internal fuse AC 24 V ± 20% (SELV / PELV) or AC 24 V class 2 (US) HD 384 50/60 Hz Max. 24 VA (same for all types) 5 A Operating data Processor Storage Accuracy class Motorola Power PC MPC885 64MB SDRAM / 32MB FLASH (96MB total) 0.5 Data backup in event of power failure Battery Backup of realtime clock Battery operation (cumulative): 10 years • Lithium type CR2032 (field replaceable)Without load: 10 years Battery Backup of SDRAM 1x AA: Battery operation...
Open the catalog to page 7Plug-in screw terminal Power supply, bus, signals Simple cable lengths, cable Connection cable Ethernet and PXM20-E types (see Installation Guide Cable type PX, CA110396) Connection cable LonWorks bus Cable type Connection cable PXM10 Connection cables for island bus Solid or stranded conductors 0.25...2.5 mm2 or 2 x 1.5 mm2 Max. 100 m Standard at least CAT5 UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) See Installation Guide CA110396 CAT5 Max. 3 m See CM110562 Protection data Housing protection standard IP 20 to EN 60529 Ambient conditions Normal operation Environmental conditions...
Open the catalog to page 8Connection terminals and interfaces Siemens Building Technologies
Open the catalog to page 91. LonWorks Data A (CLA) 2. LonWorks Data B (CLB) 3. G0 / GND 4. G / Plus 5. Unused 6. Unused 7. Unused 8. Unused RJ45 socket screened, standard connection in accordance with AT&T256 Plug (E) "HMI / Tool" (LonWorks and serial) Connection diagrams 1. LonWorks Data A (CLA) 2. LonWorks Data B (CLB) 3. GND 4. +24 V max. 300 mA (PXM20) 1. unused 2. unused 3. G0 / GND 4. G / Plus Connecting TX-I/O See Planning and Installation Guide TX-I/O, CM110562. modules and field devices Siemens Building Technologies
Open the catalog to page 10Automation stations, system controllers PXC….D Disposal The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage. • Dispose of the device through channels provided for this purpose. • Comply with all local and currently applicable laws and regulations. • Dispose of empty batteries in designated collection points. Lithium batteries: May catch fire, explode or leak. Do not short circuit, charge, disassemble, dispose of in fire, heat above 100 °C, or expose to water. Disposal: Seal battery...
Open the catalog to page 11Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 © Siemens Switzerland Ltd 2009 www.siemens.com/buildingtechnologies Delivery and technical specifications subject to change 12 / 12 Siemens Building Technologies
Open the catalog to page 122 Pages