The worldwide standard for home and building control Saving energy while ensuring an enhanced room climate Lower operating costs without loss of room comfort, thanks to communicating room thermostats Energy-efficient operation The communicating room thermostats RDG and RDF increase your building’s energy efficiency, irrespective of usage – private or commercial. This way, compliance with performance class A as per efficiency class EN 15232 can be attained. Thanks to the open communication standard KNX, the room operator units can be straight-forwardly and seamlessly integrated into existing or new building automation and control systems. Additional cost savings in terms of operation and energy consumption are made possible via the time programs, which ensure timely heating or cooling. Ease of operation The room thermostats excel in modern design and user-friendly operation. Thanks to their large displays and clear characters, temperature and time of day are easy to read. Temperature can be displayed in degrees Celsius or Fahrenheit. The measured values acquired by the room thermostats can be monitored by the building automation and control system. Very versatile – suited for heating and cooling The communicating compact devices with built-in sensors are suited for a host of applications, such as fan coil units, VAV plants, chilled ceilings, heating systems or heat pumps. Consistent design and uniform operation can thus be implemented in buildings operating with different types of heating and cooling systems. E nergy-efficient and costsaving temperature control I ntuitive and user-friendly design ensuring ease of operation G reat control accuracy for optimum room comfort S traightforward integration into building automation and control systems H igh level of functionality thanks to versatile connection facilities A pplications of the RDG160KN may reach efficiency class AA according to eu.bac

Open the catalog to page 1
Saving energy while ensuring an enhanced room climate - 2

Heat pumps Universal applications B External air temperature sensor □ Heating/cooling fan coil unit El Presence detector/Card reader El External air temperature sensor El Presence detector/Card reader El External air temperature sensor El Presence detector/Card reader El External air temperature sensor El Presence detector/Card reader

Open the catalog to page 2
Saving energy while ensuring an enhanced room climate - 3

Display and Operation Units ■■ Room thermostats ■ Technical Specifications Type RDG100KN Room thermostat with KNX communication Fan coil system and universal heating/cooling applications • Operating modes: Comfort, Economy and Protection mode • On/Off, 3-positions or PWM control outputs • Fan automatic or manual for 1- or 3-speed fan • 3 multifunctional inputs for keycard contact, external room/ return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input • Automatic or manual heating/cooling...

Open the catalog to page 3
Saving energy while ensuring an enhanced room climate - 4

Display and Operation Units ■■ Room thermostats Type RDF600KN, RDF301.50, RDF301.50H Flush-mount room thermostats with KNX communication Fan coil system and heat pump applications • Flush-mount room thermostat with LCD -- For heating and/or cooling applications -- Outputs for On/Off, 3-positions signal -- Outputs for 1- or 3-speed fan -- 2 multi-functional inputs for keycard contact, external room/return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input -- Operating modes: Comfort, Economy...

Open the catalog to page 4
Saving energy while ensuring an enhanced room climate - 5

Display and Operation Units ■■ Room thermostats Type RDU341 Flush-mount room thermostat with KNX communication VAV heating and cooling systems • Flush- mount room thermostat with LCD -- Modulating PI control -- Room or return air temperature control -- Outputs for a DC 0...10 V actuator and AC 230 V electrical heating (On/Off) -- Automatic or manual heating/cooling mode switchover -- Operating modes: Comfort, Economy and Protection function -- 2 multifunctional inputs for keycard contact, external room / return air sensors, heating/cooling switchover, switchover mode, window contact On/Off,...

Open the catalog to page 5
Saving energy while ensuring an enhanced room climate - 6

Display and Operation Units ■■ Room thermostats

Open the catalog to page 6
Saving energy while ensuring an enhanced room climate - 7

Display and Operation Units Room thermostats Selection and ordering data RDG100KN RDG100KN Room thermostat with Fan coil system and universa RDG160KN RDG160KN Room thermostat with Fan coil system, universal and heat pump applications RDF800KN RDF800KN Flush-mount room thermo- stat with KNX communication and Fan coil systems, universal heating/cooi- ng and heat pump applications thermostat with KNX communication Fan coil system and heat pump Fan coil system and heat pump applica- tions, 4 buttons to control KNX actuators via KNX S-mode (switching, dimming, Fan coil system and heat pump...

Open the catalog to page 7
Saving energy while ensuring an enhanced room climate - 8

Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel +41 41 724 24 24 Siemens Building Technologies Brunel House Sir William Siemens Square, Frimley Camberley Surrey, GU16 8QD United Kingdom Tel +44 1276 696000 Siemens Ltd Building Technologies Division 22/F, AIA Kowloon Tower, Landmark East 100 How Ming Street Kwun Tong, Hong Kong Tel +852 2870 7888 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required...

Open the catalog to page 8

All Siemens Building Technology HVAC Products catalogs and technical brochures

  1. WFx3

    2 Pages

  2. QBE

    6 Pages

  3. GCA

    6 Pages

  4. 2WR6..

    14 Pages

  5. WHE5.. WHE6

    14 Pages

Archived catalogs