1. Catalogs
  2. SIEB & MEYER AG
  3. Unit Assembly Complying EMC

Unit Assembly Complying EMC

Unit Assembly Complying EMC
1 / 75 PagesView full catalog

Unit Assembly Complying EMC

Product catalog summary
General Overview: This technical manual by SIEB & MEYER AG provides comprehensive guidelines for ensuring Electromagnetic Compatibility (EMC) in unit assembly. It covers specifications, procedures, and standards to comply with EMC directives.
1. Introduction: The manual introduces key terms and definitions related to EMC and unit assembly processes.
2. EU Directives: It outlines relevant EU directives such as the Machinery Regulation, Low-voltage Directive, and EMC Directive, emphasizing the importance of CE marking and the application of DIN EN 61800 standards.
3. EMC Product Standard: Details from the EMC Product Standard DIN EN 61800-3 are provided, explaining terms and definitions crucial for compliance.
4. EMC Rules: The document lists rules for unit assembly, line management, grounding, shielding, and the use of relays and line filters to ensure EMC compliance.
5. System Connection to Ground: Discusses professional grounding measures to address issues like earth loops and different ground potentials.
6. Machine Connection: Provides guidelines for wiring machines made of conducting and non-conducting materials.
7. Cabinet Wiring: Offers instructions on design and cable routing within cabinets to minimize EMC issues.
8. Line Emissions: Focuses on using line filters to manage emissions and ensure immunity to interferences.
9. Mounting and Connection of Line Filters: Details procedures for proper mounting and connection of line filters.
10. Immunity of Sensitive Circuits: Classifies components based on their sensitivity to electromagnetic interference.
11. Safety Aspects: Discusses safety aspects, including the use of Residual Current Devices (RCD).
12. Connection to Supply Systems: Describes various public mains supply types and their connection methods, including TN, TT, and IT systems.
13. Surge Arrestor FLASHTRAB: Provides technical data and installation guidelines for surge arrestors to protect against voltage spikes.
14. Appendix: Includes a bibliography and glossary for further reference.
Safety Warnings and Notices: Highlights different levels of risk associated with non-compliance, from imminent danger to property damage.
Technical Symbols: Explains symbols like LED indicators.
Dimensions: Provides unit dimensions for height and width.
Introduction to EMC Compliance: Emphasizes the need for an EMC-compatible environment for SIEB & MEYER devices, in line with EMC Directive 2014/30/EU.
Specifications and Standards: Stresses adherence to standards like DIN EN 61800-3 and CISPR 11 for frequency attenuation and interference suppression.
EMC Components Arrangement: Recommends arrangements for components like mains, fuses, and line filters to smooth peak loads and protect systems.
Grounding Practices: Advises on preventing ground loops and ensuring proper grounding to avoid interferences.
Machine Connection: Provides specific guidelines for connecting machines made of different materials.
Cabinet Wiring: Offers detailed instructions for wiring switch cabinets to comply with EMC guidelines.
Line Emissions and EMC Compliance: Discusses standards for EMC in different environments and the importance of filtering to manage emissions.
Line Filters: Highlights the role of line filters in managing leakage currents and ensuring EMC compliance.
Mounting and Connection of Line Filters: Provides guidelines for effective mounting and connection to prevent interference.
Immunity of Sensitive Circuits: Classifies circuits based on sensitivity and provides protection guidelines.
Safety-relevant Aspects and Residual Current Device (RCD): Discusses the impact of interference suppression on leakage currents and RCD functionality.
Residual Current Devices (RCD) and Electronic Devices: Advises on combining RCDs with electronic devices to manage leakage currents.
Touch Current: Specifies conditions for managing operational leakage currents in fixed systems.
Compatibility with RCDs: Outlines conditions for proper RCD function in systems.
Clocked Drives and EMC: Discusses the impact of clocked drives on EMC and mitigation measures.
Supply System Types: Describes different mains supply systems and their grounding methods.
General Connection Information: Provides guidelines for connecting devices to mains systems, ensuring safety and EMC compliance.
Three-phase and Single-phase Connections: Offers detailed instructions and diagrams for various connection types, emphasizing safety and compliance.
Surge Arrestor FLASHTRAB: Details the use and specifications of FLASHTRAB modules for surge protection.
Technical Data: Provides specifications for FLASHTRAB modules, including operating conditions and fuse selection.
Appendix: Lists additional literature for further reading on EMC.
Glossary and Index: Includes a glossary of EMC terms and an index for quick reference.
See more

Catalog excerpts

Unit Assembly Complying EMC-1

SIEB & MEYER Unit Assembly Complying EMC EMC General Notes

 Open the catalog to page 1
Unit Assembly Complying EMC-2

Copyright Original instructions, Copyright © 2024 SIEB & MEYER AG All rights reserved. This manual or extracts thereof may only be copied with the explicit authorization by SIEB & MEYER AG. Trademarks All product, font and company names mentioned in this manual may be trademarks or registered trademarks of their respective companies. SIEB & MEYER Worldwide For questions regarding our products and technical problems please contact us. SIEB & MEYER AG Auf dem Schmaarkamp 21 21339 Lueneburg Germany Phone: +49 4131 203 0 Fax: +49 4131 203 2000 [email protected] http://www.sieb-meyer.com SIEB & MEYER...

 Open the catalog to page 2
Unit Assembly Complying EMC-3

Unit Assembly Complying EMC - General Notes

 Open the catalog to page 3
Unit Assembly Complying EMC-4

12 Safety-relevant Aspects, Residual Current Device 14.3.5 Connection to Unearthed/Asymm. Grounded Mains without Isolating 14.4.2 Connection to Grounded/Ungrounded/Asymmetrically Grounded Mains with Isolating Unit Assembly Complying EMC - General Notes

 Open the catalog to page 4
Unit Assembly Complying EMC-5

Unit Assembly Complying EMC - General Notes

 Open the catalog to page 5
Unit Assembly Complying EMC-6

1 About this Manual This chapter describes symbols, signal words and abbreviations possibly used in this manual. You can download more documentation from the SIEB & MEYER website under https:// www.sieb-meyer.com/downloads. In this manual, the warnings listed below are used. Depending on their degree of risk, the risk levels listed below exist: A Imminent risk of injury Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ^ Follow the instructions in this manual to avoid danger. Indicates an imminently hazardous situation which, if not avoided,...

 Open the catalog to page 6
Unit Assembly Complying EMC-7

1.3 DimensionsBeside metric and inch units SIEB & MEYER uses the following units for dimensions: Abbreviation Unit Assembly Complying EMC - General Notes

 Open the catalog to page 7
Unit Assembly Complying EMC-8

Introduction SIEB & MEYER-devices only work properly and trouble-free in an EMC-compatible environment. This manual gives you valuable support in installing your devices complying to EMC. During the operation of an electronic or electric device interactions appear between the device and other nearby devices. The nearby devices act as interference source, affecting the other device as interference sink. This effect is shown in the following figure: The electromagnetic radiation emitted by device A (interference source) affects the electromagnetic immunity of device B (interference sink). Fig....

 Open the catalog to page 8
Unit Assembly Complying EMC-9

EU Directives Application of the EU directives regarding electromagnetic compatibility (EMC) with reference to SIEB & MEYER products. Basic Information The European Council enacted the EU Directives with the CE marking due to efforts to harmonize the individual national standards. The directives applying for industrial products aim to ensure the safe joint operation of electronic and mechanical apparatus without mutual interference as well as uniform safety labels of the apparatus. The EU directives are converted into bound national law in form of »harmonized standards« by the member states....

 Open the catalog to page 9
Unit Assembly Complying EMC-10

„... ‘electrical equipment’means any equipment designed for use with a voltage rating of between 50 and 1,000 V for alternating current and between 75 and 1,500 V for direct current,elektrische Betriebsmittel zur Verwendung bei einer Nennspannung...“ SIEB & MEYER-products meet the requirements of the Low-Voltage Directive 2014/35/ EU. An attestation of conformity is issued for all products.Possible peculiarities are listed in the conformity declaration. SIEB & MEYER applies the standard DIN EN 61800-2 “Adjustable speed electrical power drive systems - Part 2: General requirements”, which considers...

 Open the catalog to page 10
Unit Assembly Complying EMC-11

3.5.1 Application of the EMC Product Standard DIN EN 61800-3 SIEB & MEYER applies the EMC product standard DIN EN 61800-3 - "Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods", which considers the requirements of the following generic standards: Industrial, scientific and medical (ISM) radio frequency equipment To ensure conformity with the standard DIN EN 55016-2-1 / VDE 0877-16-2-1 you must use a line filter. ^ Consider the connection instructions of the line filter manufacturer to ensure sufficient filter effect. ^ SIEB & MEYER offers a number...

 Open the catalog to page 11
Unit Assembly Complying EMC-12

Regarding affixing the CE marking, Article 17 of the EMC Directive 2014/30/EU says: "1. The CE marking shall be affixed visibly, legibly and indelibly to the apparatus or to its data plate. Where that is not possible or not warranted on account of the nature of the apparatus, it shall be affixed to the packaging and to the accompanying documents. 2. The CE marking shall be affixed before the apparatus is placed on the market." The following table informs about the CE marking of products according to the EMC guideline. All SIEB & MEYER products are components that cannot be operated independently...

 Open the catalog to page 12
Unit Assembly Complying EMC-13

Stationary system According to the EMC Directive 2014/30/EU 'fixed installation' means: "aa particular combination of several types of apparatus and, where applicable, other devices, which are assembled, installed and intended to be used permanently at a predefined location;" Specific notes: ► Stationary systems must meet the basic protecting requirements of the EMC directive. ► Stationary systems do not require any formal conformity checks with CE marking and attestation of conformity. ► The compliance of the protecting requirements can be assumed for installations, if - CE markings have been...

 Open the catalog to page 13
Unit Assembly Complying EMC-14

The following figure shows a PDS setup with SIEB & MEYER drive components: PDS Machine manufacturer (OEM) Enclosure port Process measurement and control port Main power port Auxiliary power port Earth port Signal interface Power interface Other parts of PDS, e.g. motor SIEB & MEYER Basic Drive Module = frequency converter/servo drive Complete Drive Module = complete frequency converter/servo drive or CNC control Power Drive System = drive system of the machine/plant Generating high-frequency energy as by-product is the physically depending characteristics of every electronic apparatus with switched...

 Open the catalog to page 14

All SIEB & MEYER AG catalogs and technical brochures

  1. drivemaster2

    318  Pages

  2. 050201

    24  Pages

  3. CNC 8x.00

    106  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.