Highly Reliable and Efficient UPS designed with flexible operating modes(iECO) for larger facilities, data centers, and critical applications. 15kVA~1200kVA 6kVA~36kVA Parallel Solutions starting from 4800kVA SICON CHAT UNION ELECTRIC CO., LTD Bldg.14&15 No. 319. Xiangjiang Street High-Tech Zone. Shijiazhuang 050035 China Tel. +86 311 85903762 Email: enquiry@scupower.com Visit us: www.scupower.co
Open the catalog to page 1Data Center and Facility UPS ——In IT world, data security needs reliable power protection. Application: Date center, Government, Public infrastructures, Army, Aerospace, Communication, Transportation, Broadcast & TV, Finance, Health Care, Education & Research, Enterprise, Automated production line, etc. Safety & Reliability ■ Multiple redundancy measures, perfect fault isolation protection DSP digital control technology synchronization in sequence control, multi-level decentralized control technology integrating with one battery pack lead-acid battery or lithium battery system, complete...
Open the catalog to page 2UPS SYSTEM TEHCNICAL SPECIFICATION Model System Capacity (kVA/kW). Systems based on 15kVA module Model: CMS-30/15 Max. Capacity of system: 30KVA Configuration: 2 slots Power module model: CM15 Nominal Input Voltage Input Voltage Range Input rated frequency Power Factor Bypass Voltage Range Bypass Frequency Range Power module capacity: 15KVA Dimension: 482/442*800*662(W*D*H)mm, stand alone or embed into standard 19” cabinet Bypass synchronization tracking range Output Output active power (kW) Output rated voltage Overload Ability 10 minutes at 125% ≤ 2% (Resistive load), ≤ 4% (Non-linear...
Open the catalog to page 3UPS SYSTEM TEHCNICAL SPECIFICATION Systems based on 25kVA module System Capacity (kVA/kW). INPUT Phase Nominal Input Voltage Input Voltage Range Input rated frequency Output active power (kW) Bypass Voltage Range Bypass Frequency Range Bypass synchronization tracking range Power module model: CM25 Output active power (kW) Power module capacity: 25KVA Dimension: 600*1000*1600(W*D*H)mm, standard 19”cabinet Output rated voltage Output Frequency Overload Ability ≤ 2% (Resistive load), ≤4% (Non-linear load) Output voltage stabilization accuracy Voltage Recovering Time Transfer From Mains to...
Open the catalog to page 4UPS SYSTEM TEHCNICAL SPECIFICATION Systems based on 50kVA module System Capacity (kVA/kW). INPUT Phase Nominal Input Voltage Input Voltage Range Input rated frequency Power module model: CM50 Power Factor Power module capacity: 50KVA Bypass Voltage Range Dimension: 600*1000*2000(W*D*H)mm, standard 19” cabinet Bypass Frequency Range Bypass synchronization tracking range Output Output active power (kW) Output rated voltage Output Frequency Overload Ability Power module model: CM50 Power module capacity: 50KVA Dimension: 900*1000*2000(W*D*H)mm, standard 19” cabinet ≤ 2% (Resistive load), ≤ 4%...
Open the catalog to page 5UPS SYSTEM TEHCNICAL SPECIFICATION Systems based on 75kVA module System Capacity (kVA/kW). INPUT Phase Model: CMS-450/75 Max. Capacity of system: 450KVA Configuration: 6 slots Power module model: CM75 Nominal Input Voltage Input Voltage Range Input rated frequency Power Factor Bypass Voltage Range Power module capacity: 75KVA Dimension: 900*1000*2000(W*D*H)mm, standard 19” cabinet Bypass Frequency Range Bypass synchronization tracking range Output Output active power (kW) Output rated voltage Output Frequency Overload Ability Power module model: CM75 Power module capacity: 75KVA Output...
Open the catalog to page 6UPS SYSTEM TEHCNICAL SPECIFICATION Model System Capacity (kVA) INPUT Phase ERMS Serie Rackmount Modular UPS Nominal Input Voltage Input Voltage Range Input rated frequency Power Factor Bypass Voltage Range Power module model: ERM-06 Bypass Frequency Range Power module capacity :6kVA Bypass synchronization tracking range Dimension (W*D*H):482*635*132 mm, standalone or embed into Output active power (kW) Output rated voltage Output voltage stabilization accuracy ≤ 2% (Resistive load), ≤ 4% (Non-linear load) ≤ 1% ≤ 20ms Transfer From Mains to Battery Supply Power module capacity :6kVA...
Open the catalog to page 7Online double conversion mode Manually maintenance bypass Static Bypass Static Bypass Output Manually maintenance bypass ECO mode • UPS is running in static bypass state Static Bypass Output • Mains battery seamless switching • Meet the uninterrupted power supply and power quality of the load Static Bypass • Efficiency up to 99% • Mains battery switching time is less than 4ms iECO mode Manually maintenance bypass Static Bypass Static Bypass Output • Output meets IEC62040 and meet the power supply quality to load • Mains power supply and battery power supply seamless switching • Provide...
Open the catalog to page 8All Sicon Chat Union Electric Co. catalogs and technical brochures
-
Rack Mount UPS (Li-ion Batt)
7 Pages
Archived catalogs
-
DPM Car Charger
2 Pages
-
EVDC Charging Staiton
4 Pages
-
Micro Data Center
4 Pages
-
DSP Series UPS 1-20KVA
4 Pages
-
CMS Modular UPS 10-3200KVA
6 Pages
-
DSM Series UPS
4 Pages
-
GENIUS 6000
4 Pages
-
CMS-120 240 640 Catalogue
4 Pages
-
EVAS AC charging station
3 Pages
-
DPM DC fast charging station
2 Pages
-
SCU DSP RM UPS 1KVA-20KVA
4 Pages