EV charger Module
1 /2Pages

EV charger Module

EV charger Module
1 /2Pages

Catalog excerpts

EV charger Module-1

30kW/ 40kW AC-DC Power Module SCU DPM Series charging module is a built-in power module designed for DC charging stations. It is available in two versions based on the input power type: AC-DC and DC-DC. The module comes in 30kW, 40kW, and 60kW The charging module converts different input power sources into DC power that can be used by electric vehicles, providing a reliable DC power supply for devices requiring direct current. It features a wide DC output voltage range, ensuring compatibility with different battery packs. The module adopts three-phase active power factor correction (APFC) technology, interleaved three-level series resonance soft-switching technology, and digital control technology, offering high reliability, availability, maintainability, efficiency, and power density Rated Power: 30kW / 40kW Input Voltage Range: 304Vac ~ 480Vac DC Output Voltage Range: 50Vdc ~ 1 OOOVdc Efficiency: 97.3% 60kW AC-DC Power Module Input Voltage Range: 304Vac ~ 480Vac DC Output Voltage Range: 50Vdc ~ 1000Vdc Isolated DC-DC Power Module Rated Power: 30kW / 60kW DC Input Voltage Range: 627Vdc ~ 865Vdc DC Output Voltage Range: 50Vdc ~ 1 OOOVdc Efficiency: 98% i Compatible with AC and DC power sources i Fully digital control from input to output, ensuring precision and stability i Uses interleaved series-resonant soft switching to reduce stress on power components. a Minimal output ripple ensures no impact on battery lifespan a Fully encapsulated design improves protection and durability a Supports parallel redundancy systems and hot-swappable module replacement, significantly enhancing system availability, reliability, and maintainability

 Open the catalog to page 1
EV charger Module-2

POWER MODULE AC-DC Power Module Items Model NO Input Voltage DC-DC Power Module Output Power Constant Power Curve Output Voltage Model Rated Power Voltage Range Constant Power Curve Flow Accuracy Stabilized Voltage Accuracy Peak to Peak Noise Voltage Switch Overshoot Amplitude Slow Start Time -20℃ ~+60℃, derate to 60% of rated power at 50℃ ~60℃ Relative Humidity GB/T,CCS,NACS, CHAdeMO Constant Power Curve *All values are based on tests under optimal conditions Constant Power Curve Size (W*D*H)mm Working Temperature Power Factor

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.