DPM series DC charging module module diagram and specification
1Pages

{{requestButtons}}

Catalog excerpts

DPM series DC charging module module diagram and specification - 1

Module Diagram: Alternating Current active power factor calibration rectifier DC/DC converter input over/under voltage protection sampling feedback over temperature protection current-sharing control output over voltage, over current and short circuit communicate with master monitor output protection Specification: DPM model DPM500/30 DPM700/22 DPM750/20 DPM500/60 DPM700/43 DPM750/40 Output capacity 15KW 30KW Input voltage 380Vac three-phase three-wire Range of input voltage 260V~530V (260~304VAC ,output power derating 50% ) Input frequency Input 50/60HZ power factor Input > 0.99 current harmonic ≤ 3% Efficiency ≥ 95% Output voltage 200VDC-500VDC / 300VDC-750VDC Current regulation accuracy < 1% Voltage regulation accuracy < 0.5% Peak-to-Peak noise voltage of DC output < 0.5% Startup & Shutdown overshoot < 1% Soft start time ≤ 5S Operating temperature -20℃ ~+60℃,(during 50℃~60℃ derating to 60%) Storage temperature -40℃ ~+70℃ Ambient temperature 0~90%,40±2℃ non-condensing Altitude 2000 m 220*500*88 220*502*132 Dim

Open the catalog to page 1

All Sicon Chat Union Electric Co. catalogs and technical brochures

Archived catalogs

  1. GENIUS 6000