Group: SICK
Catalog excerpts

OPERATING INSTRUCTIONS PET Pressure transmitter Druckmessumformer SICK Sensor Intelligence.
Open the catalog to page 1
GB Operating instructions PET D Betriebsanleitung PET
Open the catalog to page 2
Operating Instructions Contents PET Operating Instructions Contents PET Inhalt Seiten 24-43 DE 8014827/2012/04/17 • AA • (2012-04) © SICK AG • Germany • All rights reserved • Subject to change without notice 3
Open the catalog to page 3
Operating Instructions 1. General information PET 1. General information ■ The pressure transmitter described in the operating instructions has been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certified to ISO 9001 and ISO 14001. ■ These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed. ■ Observe the relevant local accident prevention...
Open the catalog to page 4
Operating Instructions 1. General information PET Explanation of symbols WARNING! / J \ ... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided. A CAUTION! / | \ ... indicates a potentially dangerous situation that can result in light injuries or damage to ' * ' equipment or the environment, if not avoided. Information ... points out useful tips, recommendations and information for efficient and trouble-free operation. A CAUTION! ... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces i ~ »...
Open the catalog to page 5
Operating Instructions Before installation, commissioning and operation, ensure that the appropriate pressure transmitter has been selected in terms of measuring range, design and specific measuring conditions. Non-observance can result in serious injury and/or damage to the equipment. Only open the connections once the system has been depressurized. Observe the working conditions in accordance with chapter 3 "Technical Data". Always operate the pressure transmitter within the overpressure safety range. Further important safety instructions can be found in the individual chapters of these...
Open the catalog to page 6
Operating Instructions 2. Safety PET Operating Instructions 2. Safety PET 2.2 Personnel qualification WARNING! Risk of injury should qualification be insufficient! Improper handling can result in considerable injury and damage to equipment. The activities described in these operating instructions may only be carried out by skilled personnel who have the qualifications described below. Skilled personnel Skilled personnel are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of...
Open the catalog to page 7
Operating Instructions 2. Safety PET 2.4 Labelling / Safety marks Operating Instructions 2. Safety PET Analog output signal Measuring range Electrical connection Serial number Supply voltage If the serial number becomes illegible (e.g. due to mechanical damage or overpainting), traceability will no longer be possible. Explanation of symbols General danger symbol CE, Communaute Europeenne Instruments bearing this mark comply with the relevant European directives. Voltage DC © SICK AG • Germany • All rights reserved • Subject to change without notice
Open the catalog to page 8
Operating Instructions 3. Technical Data PET Measuring ranges Gauge pressure 8014827/2012/04/17 • AA • (2012-04) © SICK AG • Germany • All rights reserved • Subject to change without notice 9
Open the catalog to page 9
Operating Instructions 3. Technical Data PET Process connections 3.3 Mechanics / electronics G 1/8 B according to EN 837 (up to 400 bar / 5000 psi) G 1/4 A according to DIN 3852-E G 1/4 B according to EN 837 G 1/4 female according to EN 837 G 3/8 B according to EN837 1/8” NPT (up to 400 bar / 5000 psi) 1/4” NPT 1/4” NPT female R 1/4 according to ISO 7 R 3/8 according to ISO 7 7/16”-20 UNF SAE #4 J514 male with O-ring Boss (FKM) 9/16”-18 UNF SAE #4 J514 male with O-ring Boss (FKM) NBR 11 FPM/FKM 21 Without seal 11 Only for process connection G 1/4 A according to DIN 3852-E. 2) Only for...
Open the catalog to page 10
Operating Instructions 3. Technical Data PET 3) Available upon request for process connections G 1/4 A according to DIN 3852-E, 1/4”NPT, R 1/4 according to ISO 7, and 7/16”-20 UNF. 4) According to IEC 60529. The enclosure rating classes specified only apply while the sensor is connected with female connectors that provide the corresponding enclosure rating. 5) Electrical circuit in accordance with section 9.3 of UL/EN/IEC 61010-1 or an LPS to UL/EN/ IEC 60950-1 or class 2 in accordance with UL1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the...
Open the catalog to page 11
Operating Instructions 3. Technical Da ta PET 3.4 Ambient Data Ambient temperature operation © SICK AG • Germany • All rights reserved • Subject to change without notice
Open the catalog to page 12
Operating Instructions 3.5 Dimensional drawings Dimensions in mm (inches) G 1/8 B according to EN 837 Round connector M12x1 , 4-pin, IP 67 22 0.87) G 1/4 A according to DIN 3852-E Round connector M12x1 , 4-pin, IP 67 22 0.87) G 1/4 A according to DIN 3852-E For L-connector according to DIN EN 175301-803 A G 1/8 B according to EN 837 For L-connector according to DIN EN 175301-803 A © SICK AG • Germany • All rights reserved • Subject to change without notic
Open the catalog to page 13
Operating Instructions 3. Technical Data G 1/4 B according to EN 837 For L-connector according to DIN EN 175301-803 A G 1/4 female according to EN 837 Round connector M12x1 , 4-pin, IP 67 G 1/4 female according to EN 837 For L-connector according to DIN EN 175301-803 A G 1/4 B according to EN 837 Round connector M12x1 , 4-pin, IP 67 © SICK AG • Germany • All rights reserved • Subject to change without notice
Open the catalog to page 14
Operating Instructions Dimensions in mm (inches) 1/4‘‘ NPT Round connector M12x1 , 4-pin, IP 67 22 0.87) 1/4‘‘ NPT female For L-connector according to DIN EN 175301-803 A ( © SICK AG • Germany • All rights reserved • Subject to chan
Open the catalog to page 15All SICK catalogs and technical brochures
-
W4F en
17 Pages
-
SLG-2 en
14 Pages
-
IMS en
12 Pages
-
IO-Link Supplement
5 Pages
-
T-Easic FTS
56 Pages
-
T-Easic® FTS
12 Pages
-
T-Easic® FTS
4 Pages
-
FLOWSIC100 PROCESS
134 Pages
-
outdoorScan3
20 Pages
-
SPEETEC 1D
6 Pages
-
SPEETEC
2 Pages
-
midiCam
5 Pages
-
W4-3 PTFE
4 Pages
-
Photoelectric laser sensors
20 Pages
-
SMART SENSORS
48 Pages
-
Photoelectric sensors
20 Pages
-
AHS/AHM36 SSI Inox
29 Pages
-
STEEL INDUSTRY
8 Pages
-
MultiPulse
37 Pages
-
Safe Robotics Area Protection
32 Pages
-
ENCODERS AND INCLINATION SENSORS
40 Pages
-
EDS/EDM35
12 Pages
-
G2F Photoelectric sensors
20 Pages
-
TR110 Lock
20 Pages
-
24-hour helpdesk
8 Pages
-
outdoorScan3
20 Pages
-
EnforceKey Single Door
84 Pages
-
WTB16 Bluetooth®
135 Pages
-
LFV 310/330
48 Pages
-
WT18X-3P930
2 Pages
-
T-Verteiler mit Taster
8 Pages
-
Proximity Sensors
20 Pages
-
Registration Sensors
24 Pages
-
Advanced Automation Light Grids
92 Pages
-
QAL3 Master
4 Pages
-
MCS100FT FTIR Analysis System
12 Pages
-
GM960 Boiler Wall Monitor
8 Pages
-
Dust measuring devices
171 Pages
-
Automation Light Grids
228 Pages
-
Raw Gas Measurement
2 Pages
-
TranspaTect product information
16 Pages
-
GR18 product information
56 Pages
-
Top Products from SICK
486 Pages
-
SICK Essentials
118 Pages
-
Magnetic Cylinder Sensors
164 Pages
-
Presence Detection
170 Pages
-
Industrial Safety Systems
1054 Pages
-
Fluid Sensors
174 Pages
-
Encoders
388 Pages
-
Distance Sensors
404 Pages
-
Detection and Ranging Solutions
124 Pages
-
Identification Solutions
308 Pages
-
Zone control
5 Pages
-
fiber-optic sensors
5 Pages
-
PACKAGING2009/10
20 Pages
-
Inductive proximity sensors
5 Pages
-
Photoelectric sensors
5 Pages
Archived catalogs
-
safety laser scanners
5 Pages
-
3D cameras
6 Pages
-
Miniature photoelectric sensors
5 Pages
-
MCS300P Superior in front
4 Pages
-
MKAS Compact Analysis system
2 Pages
-
FLOWSIC 600
4 Pages
-
GM32 In-situ gas analyzer
8 Pages
-
W9-2 Small photoelectric sensors
7 Pages
-
Product overview Industrial Sensors
100 Pages
-
News Factory Automation
8 Pages