Catalog excerpts

GMS800 FIDOR® TOTAL HYDROCARBON ANALYZER MEAC DATA ACQUISITION SYSTEM Tested and reliable emission data management Continuous monitoring of hydrocarbon emissions CEMS solutions
Open the catalog to page 1
MEAC: tested and reliable emission data management Protecting the natural living space is becoming an increasingly important and concrete legal requirement. Environmentally relevant emissions must be recorded permanently and continuously, and checked with utmost reliability. Their qualitative assessment over time is essential, since companies responsible for emissions must adhere to limits and provide the authorities with full documentation. SICK has long-term experience in the continuous measurement, monitoring and remote transfer of emission data. Safe data collection Data output and...
Open the catalog to page 2
MEAC system overview Data acquisition unit DAU Collection of measured data, preparation and transfer to the Emission-PC, including data buffering in case of failures. Alternatively, use of field modules possible for small applications. Process control system Data acquisition unit DAU Decentralized data collection Emission-PC EPC PC with Window operating system and evaluation software for the data received. Up to 16 devices (DAU, field modules, Modbus, OPC, etc.) connectible as options. Provision of data via network for workstations and data transfer to authority via modem. Can be connected...
Open the catalog to page 3
MEAC CEMS solutions TESTED AND RELIABLE EMISSION DATA MANAGEMENT Product description The MEAC offers continuous acquisition, evaluation, storage and visualization, as well as transfer of emission data for modern emission data management. Up to 16 data acquisition units, each equipped with a scalable ring buffer, can be connected to the central Emission-PC. It is also possible to integrate process control systems. MEAC is TÜV approved and certified. The MEAC2012 version is designed to meet German legislative requirements, while the MEAC2000 EU complies with European directives and...
Open the catalog to page 4
CEMS solutions MEAC Fields of application • Acquisition of measured and operating data for continuous emission monitoring • Data preparation in compliance with legislation • Free customized and legislative reporting • Data transmission rate to authority Detailed technical data System MEAC2012 Conformities EN 14181 TA-Luft (Prevention of Air Pollution) 1. BImSchV (FICA) 2. BImSchV (FICA) 13. BImSchV (FICA) 17. BImSchV (FICA) 30. BImSchV (FICA) 31. BImSchV (FICA) BEP 2010 Status Flagging and Classification (SKK) 2012 Calculation interval Integration time Value type 5 s value, short term...
Open the catalog to page 5
MEAC CEMS solutions MEAC2000 EU Conformities Calculation interval Integration time Value type 1-min. value, short term average (STA), prognosis for STA, daily average, prognosis for daily average, monthly average, annual average, daily total emission, monthly total emission, annual total emission Software modules Evaluation software version 1.28 EU (parameterization necessary) Network access software for client PC (option) Remote access software for central PC (option; emission remote transfer software is required for the Emission PC when a modem is used) Remote maintenance (option) Process...
Open the catalog to page 6
CEMS solutions MEAC Control unit Emission-PC Ambient temperature Electrical safety Enclosure rating MODBUS RTU (slave; via RS-232/RS-485) MODBUS TCP (slave; via Ethernet) PROFIBUS DP (save; via RS-485) OPC DA 2.0 (client; via Ethernet) Electrical connection Voltage 230 V AC System requirements for customer PC: Operating system: Windows XP Professional SP3, Windows 7 Ultimate 32/64bit SP1 Processor: 2.5 GHz RAM: 2 GB RAM Hard disk: 2 x 300 GB Power supply unit: 500 W Free slots: 3 x PCI for radio clock, modem and watchdog I/O module Data acquisition unit Ambient temperature Electrical safety...
Open the catalog to page 7
MEAC CEMS solutions Field module Ambient temperature Electrical safety Enclosure rating Analog outputs Analog inputs 2 outputs: 0 to 20 mA Max. 16 outputs, single-pole grounded, not volt-free Digital outputs Digital inputs MODBUS RTU (slave; via RS-485, Ethernet as option) via Emission-PC and MEAC software Electrical connection Voltage Ordering information Our regional sales organization will help you to select the optimum device configuration. 8010981/2013-07 Subject to change without notice
Open the catalog to page 8
Dimensional drawings (dimensions in mm) Data acquisition unit Subject to change without notice
Open the catalog to page 9
Subject to change without notice
Open the catalog to page 10
WWW.MYSICK.COM – SEARCH ONLINE AND ORDER Search online quickly and safely – with the SICK “Finders” Efficiency – with the e-commerce tools from SICK Product Applications Literature Service Accessories Software Product Finder: We can help you to quickly target the product that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of products from SICK. Find out prices...
Open the catalog to page 11
£ SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With g more than 6,500 employees and over 50 subsidiaries and equity investments as well as numerous repre- m sentative offices worldwide, we are always close to our customers. A unique range of products and services 9 creates the perfect basis for controlling processes securely and efficiently, protecting individuals from o accidents and preventing damage to the environment. § We have extensive experience in various industries and understand their processes and requirements. 8 With...
Open the catalog to page 12All SICK catalogs and technical brochures
-
W4F en
17 Pages
-
SLG-2 en
14 Pages
-
IMS en
12 Pages
-
IO-Link Supplement
5 Pages
-
T-Easic FTS
56 Pages
-
T-Easic® FTS
12 Pages
-
T-Easic® FTS
4 Pages
-
FLOWSIC100 PROCESS
134 Pages
-
SPEETEC 1D
6 Pages
-
SPEETEC
2 Pages
-
midiCam
5 Pages
-
W4-3 PTFE
4 Pages
-
Photoelectric laser sensors
20 Pages
-
SMART SENSORS
48 Pages
-
Photoelectric sensors_2019
20 Pages
-
AHS/AHM36 SSI Inox
29 Pages
-
STEEL INDUSTRY
8 Pages
-
MultiPulse
37 Pages
-
Safe Robotics Area Protection
32 Pages
-
ENCODERS AND INCLINATION SENSORS
40 Pages
-
EDS/EDM35
12 Pages
-
G2F Photoelectric sensors
20 Pages
-
TR110 Lock
20 Pages
-
24-hour helpdesk
8 Pages
-
outdoorScan3
20 Pages
-
EnforceKey Single Door
84 Pages
-
WTB16 Bluetooth®
135 Pages
-
PET Pressure transmitter
44 Pages
-
LFV 310/330
48 Pages
-
WT18X-3P930
2 Pages
-
T-Verteiler mit Taster
8 Pages
-
Proximity Sensors
20 Pages
-
Registration Sensors
24 Pages
-
Advanced Automation Light Grids
92 Pages
-
QAL3 Master
4 Pages
-
MCS100FT FTIR Analysis System
12 Pages
-
GM960 Boiler Wall Monitor
8 Pages
-
Dust measuring devices
171 Pages
-
Automation Light Grids
228 Pages
-
Raw Gas Measurement
2 Pages
-
TranspaTect product information
16 Pages
-
GR18 product information
56 Pages
-
Top Products from SICK
486 Pages
-
SICK Essentials
118 Pages
-
Magnetic Cylinder Sensors
164 Pages
-
Presence Detection
170 Pages
-
Industrial Safety Systems
1054 Pages
-
Fluid Sensors
174 Pages
-
Encoders
388 Pages
-
Distance Sensors
404 Pages
-
Detection and Ranging Solutions
124 Pages
-
Identification Solutions
308 Pages
-
Zone control
5 Pages
-
fiber-optic sensors
5 Pages
-
PACKAGING2009/10
20 Pages
-
Inductive proximity sensors
5 Pages
Archived catalogs
-
Photoelectric sensors_2012
5 Pages
-
safety laser scanners
5 Pages
-
3D cameras
6 Pages
-
Miniature photoelectric sensors
5 Pages
-
MCS300P Superior in front
4 Pages
-
MKAS Compact Analysis system
2 Pages
-
FLOWSIC 600
4 Pages
-
GM32 In-situ gas analyzer
8 Pages
-
W9-2 Small photoelectric sensors
7 Pages
-
Product overview Industrial Sensors
100 Pages
-
News Factory Automation
8 Pages