MULTICOMPONENT ANALYZER SYSTEMS CEMS Solution Sensor Intelligence.
Open the catalog to page 1CONTINUOUS, EXTRACTIVE FLUE GAS MONITORING On MCS100E HW, from sampling to the cell, all components that are in contact with the sample gas are heated to above dew point and thus protected from corrosion. On MCS100E CD/PD, gas drying is performed via a cooler/permeation dryer. The sample gas pump is located in the MCS100E system cabinet. Fast sample gas exchange minimizes adsorption or desorption effects, especially of HCl and NH3. In case of a malfunction, the system is purged with zero gas and thus protected from corrosion. During span gas feeding on the sampling probe, the complete extraction...
Open the catalog to page 2Heated sample gas line Bifrequency and gas filter correlation principle The single beam infrared filter photometer of the analyzer allows the simultaneous use of bifrequency and gas filter correlation methods. The cell is optimized for fast gas exchange and thermostatically controlled to high temperatures. A sintered metal protective filter is fitted in the sample gas inlet. An integrated flow meter triggers an alarm when the value is below the set limit value. Optionally, the analyzer can contain an oxygen measurement. The optional use of an internal calibration check allows fast checking of...
Open the catalog to page 3EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT Product description The MCS100E HW is an analyzer system for extractive measurement of up to 8 IR-active gas compounds. It can be supplemented with oxygen and total hydrocarbon analyzers. From probe sampling to cell, all components that are in contact with the sample gas are heated above dew point and thus protected from corrosion. This hot measurement technique allows the measurement of water soluble components HCl and NH3. At a glance • Extractive measurement of up to 8 IR-active gas compounds • Additional oxygen and total hydro carbon analyzers...
Open the catalog to page 4CEMS solutions MCS100E HW Fields of application • Emission monitoring of waste incineration plants • Monitoring of combustion plants with secondary fuels • Flue gas monitoring in cement plants • Emission monitoring of refineries • Emission monitoring of heavy oil fired diesel engines Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. MCS100E HW system Measured values Performance tested measurands Measurement...
Open the catalog to page 5MCS100E HW CEMS solutions Conformities Electrical safety Enclosure rating Analog outputs 4 outputs: 0/4 ... 20 mA, 500 Ω Max. 64 outputs with opto box via optical fibre possible Analog inputs 4 inputs: 0/4 ... 20 mA Max. 64 inputs with opto box via optical fibre possible Digital outputs 12 outputs: 40 V, 1 A Max. 64 outputs with opto box via optical fibre possible Digital inputs 4 inputs: 50 V AC, 4 A / 24 V DC, 4 A Max. 64 inputs with opto box via optical fibre possible RS-232 RS-485 Modem Additional interfaces on request MODBUS Additional buses on request Via integrated operating unit Two operating...
Open the catalog to page 6CEMS solutions MCS100E HW Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings (Dimensions in mm (inch)) MCS100E HW 806 (31.73) 735 (28.94) 8010576/2013-12 Subject to change without notice
Open the catalog to page 7EMISSION MONITORING OF VERY SMALL MEASURING RANGES INCLUDING HCL Product description The MCS100E PD is an analyzer system for extractive measurement of up to 8 IR-active gas compounds. It can be supplemented with an oxygen sensor. The gas is dried by a permeation dryer, whereby HCl remains in the gas. Very small measuring ranges are possible, especially for SO2, NO, NO2 and HCl. At a glance • Extractive measurement of up to 8 IR-active gas compounds • Additional oxygen sensor as an option • Integrated permeation dryer • Test gas supply at the gas sampling probe or at the analyzer • Back-flushing...
Open the catalog to page 8CEMS solutions MCS100E PD Fields of application • Flue gas monitoring in waste incineration plants • Clean gas monitoring in industrial plants • Emission monitoring in refineries Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. MCS100E PD system Measured values Performance tested measurands Measurement principles Interference filter correlation, Gas filter correlation, Zirconium dioxide sensor Sample...
Open the catalog to page 9MCS100E PD CEMS solutions Enclosure rating Analog outputs 4 outputs: 0/4 ... 20 mA, 500 Ω Max. 64 outputs with opto box via optical fibre possible Analog inputs 4 inputs: 0/4 ... 20 mA Max. 64 inputs with opto box via optical fibre possible Digital outputs 12 outputs: 40 V, 1 A Max. 64 outputs with opto box via optical fibre possible Digital inputs 4 inputs: 50 V AC, 4 A / 24 V DC, 4 A Max. 64 inputs with opto box via optical fibre possible RS-232 RS-485 Modem Additional interfaces on request MODBUS Additional buses on request Via integrated operating unit Two operating levels, one password-protected...
Open the catalog to page 10CEMS solutions MCS100E PD Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings (Dimensions in mm (inch)) MCS100E PD 806 (31.73) 735 (28.94) 8010576/2013-12 Subject to change without notice
Open the catalog to page 11EMISSION MONITORING OF VERY SMALL MEASURING RANGES Product description The MCS100E CD is an analyzer system for extractive measurement of up to 8 IR-active gas compounds. It can be supplemented with an oxygen sensor. The gas is dried by an integrated gas cooler allowing measurement of very small measuring ranges, especially for SO2, NO and NO2. At a glance • Extractive measurement of up to 8 IR-active gas compounds • Optional oxygen sensor available • Integrated gas cooler • Test gas supply at the gas sampling probe or at the analyzer • Back-purging of gas sampling probe for cleaning of filters...
Open the catalog to page 1217 Pages
12 Pages
14 Pages
4 Pages
5 Pages
56 Pages
12 Pages
134 Pages
6 Pages
2 Pages
5 Pages
4 Pages
20 Pages
48 Pages
20 Pages
29 Pages
8 Pages
37 Pages
32 Pages
40 Pages
12 Pages
20 Pages
20 Pages
8 Pages
20 Pages
84 Pages
135 Pages
44 Pages
48 Pages
2 Pages
8 Pages
20 Pages
24 Pages
486 Pages
92 Pages
4 Pages
12 Pages
8 Pages
171 Pages
228 Pages
2 Pages
16 Pages
56 Pages
118 Pages
164 Pages
170 Pages
1054 Pages
308 Pages
174 Pages
388 Pages
404 Pages
124 Pages
5 Pages
5 Pages
20 Pages
5 Pages
5 Pages
7 Pages
8 Pages
4 Pages
2 Pages
4 Pages
5 Pages
6 Pages
5 Pages
100 Pages
8 Pages