Overview
The EuroFID is a heated flame ionisation detector designed for measuring volatile organic compounds (VOC) in exhaust air and gas. It is particularly useful for LEL monitoring in drying facilities and detecting leaks in solvent-filled containers. The analyzer can be integrated with a control unit and terminal box to form a complete system.

Key Features
  • Integrated dilution of sample gas
  • No moving parts, reducing maintenance
  • All gas paths are heated to prevent condensation
  • Optimized detector geometry

Benefits
  • Low maintenance due to wear-resistant design
  • Prevents condensation through heating and dilution
  • EC type approved as a gas warning device
  • Can be directly mounted on the gas duct

Applications
  • LEL monitoring in solvent-based product production
  • Workplace monitoring and VOC measurement in ambient air
  • Leak detection in solvent-filled containers

Technical Specifications
  • Measuring Principle: Flame ionisation detection
  • Measuring Ranges: Corg: 0 ... 10 ppm / 0 ... 100 Vol.-%
  • Sample Quantity: 40 ... 80 l/h
  • Process Temperature: Inline type: 0 ... 350 °C, Other types: 0 ... 200 °C
  • Process Pressure: 50 ... 50 hPa relative
  • Ambient Temperature: Analyzer, terminal box: 0 ... 55 °C, Operating unit: 0 ... 40 °C
  • Ambient Humidity: 0 ... 90% relative humidity
  • Conformities: 2000/76/EC, 2001/80/EC, EN 14181, GOST, MCERTS, German Clean Air Regulations, U.S. EPA compliant
  • Ex-approvals ATEX: Ex-type Zone 1: II 2 G EEx p IIB+H2 T=170...220 °C
  • Electrical Safety: CE, EMC, LVD

Enclosure and Outputs
  • Enclosure Rating: 19''-rack, wall mounting enclosure, control unit: IP 20, Inline type: IP 65
  • Analogue Outputs: 2 outputs: 0/4 ... 20 mA, 500 Ω floating
  • Analogue Inputs: 4 inputs, 0.25 ... 20 V
  • Digital Outputs: 8 transistor switches: 24 V AC/DC, 100 mA floating
  • Digital Inputs: 3 inputs 24 V DC ±10%, floating
  • Interfaces: RS-232c (optional)

Operation and Components
  • Operation: Menu-driven via separate control unit
  • Device Types: 19''-rack, Type for Ex-zone 1, Inline type, Wall mounting enclosure
  • System Components: Analyzer, Operating unit, Terminal box

Contact Information
For more information, contact SICK AG or visit their website at www.sick.com.
See more

Catalog excerpts

Gas Analyzers Total hydrocarbon analyzer-1

EuroFID www.mysick.com ONLINE DATA SHEET Gas Analyzers Total hydrocarbon analyzer

 Open the catalog to page 1
Gas Analyzers Total hydrocarbon analyzer-2

Gas Analyzers Total hydrocarbon analyzer Model Name > EuroFID The EuroFID is a heated flame ionisation detector for determination of volatile organic compounds (VOC) in exhaust air and exhaust gas. Typical applications are LEL monitoring in drying facilities and leakage detection for solvent-filled containers. The analyzer as inline type can be combined with the control unit and terminal box to form a system. At a glance • Integrated dilution of sample gas • No moving parts • All gas paths are heated • Optimum detector geometry Your benefits • Low maintenance effort due to wear-resistant design...

 Open the catalog to page 2
Gas Analyzers Total hydrocarbon analyzer-3

Enclosure rating: Analogue outputs: Analogue inputs: Digital outputs: Digital inputs: Interfaces: Operation: Device types: System components: Note: 19''-rack, wall mounting enclosure, control unit: IP 20, Inline type: IP 65 2 outputs: 0/4 ... 20 mA, 500 Ω floating 4 inputs , 0.25 ... 20 V assignment depending on system 8 tansistor switches: 24 V AC/DC, 100 mA floating; for status signals ok, failure, calibration, maintenance request and alarms 3 inputs 24 V DC ±10 %, floating, triggerable RS-232c (option) floating; for printer, I/O-box, remote control, fieldbus Menu-driven operation via separate...

 Open the catalog to page 3
Gas Analyzers Total hydrocarbon analyzer-4

USmod 4c int37 Australia Phone +61 3 9497 4100 1800 334 802 – tollfree E-Mail [email protected] Belgium/Luxembourg Phone +32 (0)2 466 55 66 E-Mail [email protected] Brasil Phone +55 11 3215-4900 E-Mail [email protected] Canada Phone +1(952) 941-6780 1 800-325-7425 – tollfree E-Mail [email protected] Ceská Republika Phone +420 2 57 91 18 50 E-Mail [email protected] China Phone +852-2763 6966 E-Mail [email protected] Danmark Phone +45 45 82 64 00 E-Mail [email protected] Deutschland Phone +49 211 5301-301 E-Mail [email protected] España Phone +34 93 480 31 00 E-Mail [email protected] France Phone +33 1 64 62 35 00...

 Open the catalog to page 4

All SICK catalogs and technical brochures

  1. W4F en

    17  Pages

  2. IMS en

    12  Pages

  3. SLG-2 en

    14  Pages

  4. T-Easic® FTS

    4  Pages

  5. T-Easic FTS

    56  Pages

  6. T-Easic® FTS

    12  Pages

  7. SPEETEC 1D

    6  Pages

  8. SPEETEC

    2  Pages

  9. midiCam

    5  Pages

  10. W4-3 PTFE

    4  Pages

  11. SMART SENSORS

    48  Pages

  12. MultiPulse

    37  Pages

  13. EDS/EDM35

    12  Pages

  14. TR110 Lock

    20  Pages

  15. outdoorScan3

    20  Pages

  16. LFV 310/330

    48  Pages

  17. WT18X-3P930

    2  Pages

  18. QAL3 Master

    4  Pages

  19. SICK Essentials

    118  Pages

  20. Fluid Sensors

    174  Pages

  21. Encoders

    388  Pages

  22. Distance Sensors

    404  Pages

  23. Zone control

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.