FLG Standard automation light grids
12Pages

{{requestButtons}}

Catalog excerpts

FLG Standard automation light grids - 1

FLG Standard automation light grids Two in one: sender and receiver in one housing

Open the catalog to page 1
FLG Standard automation light grids - 2

Standard automation light grids FLG: Two in one: sender and receiver in one housing The FLG (Frame Light Grid) from SICK is a precise, installation-friendly solution for detecting free-falling objects. The FLG is a one-way system in which the sender and receiver are permanently installed in a frame. It is available in three sizes for three different detection ranges and can detect small items down to 2 mm in size. Various adjustments - integrated pushbutton lock S Operating mode (dynamic or static) So easy to integrate Sender and receiver are permanently installed into the FLG and aligned...

Open the catalog to page 2
FLG Standard automation light grids - 3

Example applications Ejection control for small components Even when speed is required for large quantities – in dynamic mode, the FLG detects everything that falls through the grid: Metal parts at punching machines, parts ejected from conveyor systems, tablets in the primary packaging of pharmaceutical products or screw connections in bottling plants. It is important to isolate the parts beforehand, since the FLG can only detect one part at a time. In static operation, it can also be used to monitor thread or cable breaks. 8015080/2012-10-12 Subject to change without notice Wide range of...

Open the catalog to page 3
FLG Standard automation light grids - 4

Standard automation light grids Two in one: sender and receiver in one housing Product description The FLG (frame light grid) standard automation light grid is an innovative solution that combines sender and receiver in one housing to detect small parts. The individual adjustment of sender and receiver is no longer necessary. In dynamic operating mode, the FLG performs reject and removal control of work pieces in press and punch machines and also can be used in packaging applications. In static operating mode, it can be used to monitor thread continuity. With a monitored area of 250, 180 or...

Open the catalog to page 4
FLG Standard automation light grids - 5

Standard automation light grids Detailed technical data Features Technology Switching light grid Light/dark switching adjustable by means of rotary switch Dynamic or static function adjustable by means of rotary switch. Performance Response time Mechanics/electronics Wave length Power consumption Residual ripple Output current Imax. Initialization time Housing material Aluminum, painted Enclosure rating Circuit protection VS connections reverse-polarity protected Output Q short-circuit protected Interference suppression Switching frequency Limit values, reverse-polarity protected,...

Open the catalog to page 5
FLG Standard automation light grids - 6

Standard automation light grids Ordering information FLGx-200xxx1x •• Version: close •• Connection type: Connector M12, 4-pin Beam separation Minimum detectable object (MDO) Model name Model name 2 mm MDO in limited detection area. FLGx-200xxx2x •• Version: open •• Connection type: Connector M12, 4-pin Beam separation Minimum detectable object (MDO) Dynamic: 2 mm 1) Static: 6 mm 2 mm MDO in limited detection area. 8015080/2012-10-12 Subject to change without notice

Open the catalog to page 6
FLG Standard automation light grids - 7

Standard automation light grids Dimensional drawing 8015080/2012-10-12 Subject to change without notice 1 Yellow LED: Output state 2 Red LED: Error or key lock function active (blinking)

Open the catalog to page 7
FLG Standard automation light grids - 8

Standard automation light grids Connection type and diagram Locking: After the last setting, the frame waits 15 minutes then locks the potentiometer. When the potentiometers are locked, the red LED flashes every time you turn any button. Unlocking: 1 To unlock the potentiometers, turn the mode button on the “Stat. NO” position. 2 Turn in less than 4 seconds, on the “Dyn. NO” position. The potentiometers are then unlocked and the settings are updated with the current position of the potentiometers. <4s Notice: If the mode button is already in the “Stat. NO” position, change mode previously...

Open the catalog to page 8
FLG Standard automation light grids - 9

Standard automation light grids Recommended accessories Plug connectors and cables Brief description Female connector, M12, 4-pin, straight, 2 m, PVC Female connector, M12, 4-pin, straight, 5 m, PVC Female connector, M12, 4-pin, straight, 10 m, PVC Model name Female connector, M12, 4-pin, straight, 15 m, PVC Female connector, M12, 4-pin, straight, 5 m, PUR halogen free Female connector, M12, 4-pin, straight, 10 m, PUR halogen free Female connector, M12, 4-pin, straight, 15 m, PUR halogen free Female connector, M12, 4-pin, angled, 2 m, PVC Female connector, M12, 4-pin, angled, 5 m, PVC...

Open the catalog to page 9
FLG Standard automation light grids - 10

8015080/2012-10-12 Subject to change without notice

Open the catalog to page 10
FLG Standard automation light grids - 11

Singleturn/Multiturn light grids Standard automationHIPERFACE DSL® www.mysick.com – your quick access to maximum efficiency FLG Search online quickly and safely with the SICK „Finders“ Product Applications Literature Service Connection diagram Accessories Spare part Software Product Finder: We can help you to quickly target the p ­ roduct that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or p ­ roduct group. Literature Finder: Go directly to the operating instructions, technical information,...

Open the catalog to page 11
FLG Standard automation light grids - 12

Leading technologies Unique product range Comprehensive services With a staff of more than 5,000 and over 50 subsidiaries and representations worldwide, SICK is one of the leading and most successful manufacturers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans – there is no need to settle for anything less than the best. •• Non-contact detecting, counting, classifying, positioning and measuring of...

Open the catalog to page 12

All SICK catalogs and technical brochures

  1. W4F en

    17 Pages

  2. SLG-2 en

    14 Pages

  3. IMS en

    12 Pages

  4. T-Easic FTS

    56 Pages

  5. T-Easic® FTS

    12 Pages

  6. outdoorScan3

    20 Pages

  7. SPEETEC 1D

    6 Pages

  8. SPEETEC

    2 Pages

  9. midiCam

    5 Pages

  10. W4-3 PTFE

    4 Pages

  11. SMART SENSORS

    48 Pages

  12. MultiPulse

    37 Pages

  13. EDS/EDM35

    12 Pages

  14. TR110 Lock

    20 Pages

  15. outdoorScan3

    20 Pages

  16. LFV 310/330

    48 Pages

  17. WT18X-3P930

    2 Pages

  18. QAL3 Master

    4 Pages

  19. SICK Essentials

    118 Pages

  20. Fluid Sensors

    174 Pages

  21. Encoders

    388 Pages

  22. Zone control

    5 Pages

Archived catalogs

  1. 3D cameras

    6 Pages

  2. FLOWSIC 600

    4 Pages