CLV63x, CLV64x, CLV65x Bar code scanners
80Pages

{{requestButtons}}

Catalog excerpts

CLV63x, CLV64x, CLV65x Bar code scanners - 1

OPERATING INSTRUCTIONS

Open the catalog to page 1
CLV63x, CLV64x, CLV65x Bar code scanners - 2

Described product CLV63x CLV64x CLV65x Manufacturer SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany Legal information This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐ tion, abridgment or translation of this document is prohibited without the express writ‐ ten permission of SICK AG. The trademarks stated in this document are the property of their respective owner. © SICK AG. All...

Open the catalog to page 2
CLV63x, CLV64x, CLV65x Bar code scanners - 3

8019588/ZMG6/2017-07-04 | SICK Subject to change without notice

Open the catalog to page 3
CLV63x, CLV64x, CLV65x Bar code scanners - 4

8019588/ZMG6/2017-07-04 | SICK Subject to change without notice

Open the catalog to page 4
CLV63x, CLV64x, CLV65x Bar code scanners - 5

ABOUT THIS DOCUMENT 1 About this document Information on the operating instructions These operating instructions provide important information on how to use devices from SICK AG. Prerequisites for safe work are: Compliance with all safety notes and handling instructions supplied. Compliance with local work safety regulations and general safety regulations for device applications The operating instructions are intended to be used by qualified personnel and electrical specialists. NOTE Read these operating instructions carefully before starting any work on the device, in order to familiarize...

Open the catalog to page 5
CLV63x, CLV64x, CLV65x Bar code scanners - 6

1 ABOUT THIS DOCUMENT WARNING … indicates a potentially dangerous situation, which may lead to a fatality or serious injuries if not prevented. CAUTION … indicates a potentially dangerous situation, which may lead to minor/slight injuries if not prevented. NOTICE … indicates a potentially harmful situation, which may lead to material damage if not prevented. NOTE … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. Further information NOTE All the documentation available for the device can be found on the online product page at: The...

Open the catalog to page 6
CLV63x, CLV64x, CLV65x Bar code scanners - 7

The device is an intelligent, opto-electronic SICK ID sensor and is used for automatic, fixed identification and decoding of bar codes on moving or stationary objects. The data content of the decoded bar codes is sent by the device to a higher-level control (PLC) for further coordinating processing. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation. 2.2 Incorrect use • The device does...

Open the catalog to page 7
CLV63x, CLV64x, CLV65x Bar code scanners - 8

With special variants, where optional extras have been ordered, or owing to the latest technical changes, the actual scope of delivery may vary from the features and illustrations shown here. Modifications and conversions NOTICE Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation. WARNING Risk of injury due to insufficient training. Improper handling of...

Open the catalog to page 8
CLV63x, CLV64x, CLV65x Bar code scanners - 9

Hazard warnings and operational safety Please observe the safety notes and the warnings listed here and in other chapters of these operating instructions to reduce the possibility of risks to health and avoid dan‐ gerous situations. Laser radiation The device works with a red light laser diode in the wavelength range between 650 nm and 660 nm. CAUTION Optical radiation: Laser class 2 The human eye is not at risk when briefly exposed to the radiation for up to 0.25 sec‐ onds. Exposure to the laser beam for longer periods of time may cause damage to the retina. The laser radiation is harmless...

Open the catalog to page 9
CLV63x, CLV64x, CLV65x Bar code scanners - 10

2 SAFETY INFORMATION NOTE No maintenance is required to ensure compliance with laser class 2. Warning symbol on the device The colored laser warning label is fitted in combination with the type label on the rear of the device. In addition to other information, the type label of the device in use also contains the laser output data. This consists of: Laser output power (maximum/average), wave‐ length or wavelength range, and pulse time duration. The data is located on the lower section of the type label, see "Type label", page 12. Figure 2: Example of a laser warning sign on the device What...

Open the catalog to page 10
CLV63x, CLV64x, CLV65x Bar code scanners - 11

Using the SOPAS ET configuration software, on the Illumination Control device page During GSD configuration with the “10_Object Trigger Ctrl” module (Profinet/Profi‐ bus) In the default setting, laser timeout is deactivated. The laser diode is permanently or repeatedly switched on in the following device sta‐ tuses: ■ ■ In the “Percentage Evaluation” and “Auto Setup” operating modes (only used tem‐ porarily for configuration/diagnosis) In reading operation in the PSDI types “Auto pulse” (adjustable duty cycle) or “free.” If timeout is activated, it will have no effect here. Switching off...

Open the catalog to page 11
CLV63x, CLV64x, CLV65x Bar code scanners - 12

Product descriptionProduct IDType label The type label gives information for identification of the device. An existing UL certification can be found on the type label. SICK Pulse duration <300ps 1® Figure 3: Type label design for the device ® Type designation @ Serial number 4 Laser output data Type code The devices of the CLV63x, CLV64x, and CLV65x product families are arranged according to the following type code: 8019588/ZMG6/2017-07-04 | SICK Subject to change without notice

Open the catalog to page 12
CLV63x, CLV64x, CLV65x Bar code scanners - 13

1) Refers to the longitudinal axis of the device. 2) 1 x male connector, M12, 12-pin, A-coded and 1 x female connector, M12, 4-pin, D-coded. 3) 1 x male connector, M12, 17-pin, A-coded and 1 x female connector, M12, 4-pin, D-coded. 4) 2 x digital switching inputs and 2 x digital switching outputs. 5) 1 x digital switching input. NOTE Not all combinations are possible according to the type code. The available device variants can be found online at: • www.sick.com/CLV63x • www.sick.com/CLV64x • www.sick.com/CLV65x 8019588/ZMG6/2017-07-04 | SICK Subject to change without notice

Open the catalog to page 13

All SICK catalogs and technical brochures

  1. W4F en

    17 Pages

  2. SLG-2 en

    14 Pages

  3. IMS en

    12 Pages

  4. T-Easic FTS

    56 Pages

  5. T-Easic® FTS

    12 Pages

  6. outdoorScan3

    20 Pages

  7. SPEETEC 1D

    6 Pages

  8. SPEETEC

    2 Pages

  9. midiCam

    5 Pages

  10. W4-3 PTFE

    4 Pages

  11. SMART SENSORS

    48 Pages

  12. MultiPulse

    37 Pages

  13. EDS/EDM35

    12 Pages

  14. TR110 Lock

    20 Pages

  15. outdoorScan3

    20 Pages

  16. LFV 310/330

    48 Pages

  17. WT18X-3P930

    2 Pages

  18. QAL3 Master

    4 Pages

  19. SICK Essentials

    118 Pages

  20. Fluid Sensors

    174 Pages

  21. Encoders

    388 Pages

  22. Zone control

    5 Pages

Archived catalogs

  1. 3D cameras

    6 Pages

  2. FLOWSIC 600

    4 Pages