1. Catalogs
  2. SIBA
  3. Miniature Fuses

Miniature Fuses

Miniature Fuses
1 / 100 PagesView full catalog

Miniature Fuses

Product catalog summary
Introduction
Miniature fuses are essential components in electrical systems, designed to protect devices from excessive current loads by disconnecting faulty components. They are widely used in consumer electronics and industrial applications.
Designs
Traditional fuses are cylindrical, with dimensions of 5 mm x 20 mm or 6.3 mm x 32 mm, capable of handling short-circuit currents up to several kiloamperes at voltages up to 1000 V. Sub-miniature and SMD fuses are used for PCB mounting with rated voltages up to 250 V.
Technical Notes
  • Terminology: Miniature fuses consist of a fuse-link and a fuse-holder. The fuse-link contains the fuse-element that melts when the rated current is exceeded.
  • Rated Voltage (Urat): The effective value of a sinusoidal AC voltage at 50 Hz.
  • Rated Current (In): The effective value under which the fuse-link can operate continuously.
  • Rated Breaking Capacity (I1): The maximum current the fuse-link can interrupt at the rated voltage.
  • Voltage Drop (∆U): Measured at the rated current and 23°C ambient temperature.
  • Pre-arcing Integral (I²tS): Indicates the electrical load leading to the melting of the fuse-element.
  • Operating Integral (I²tA): Measures the load on downstream components during a short-circuit event.
  • Power Dissipation (Pv): Calculated by multiplying the non-fusing current by the voltage drop after one hour.
Structure of Miniature Fuse-Links
  • Glass Tube: Used for currents not exceeding 35 A or 10 Irat.
  • Reinforced Glass Tube: Can handle currents up to 150 A at rated voltage.
  • Filled Glass Tube: With quartz sand filling, can interrupt currents up to 1000 A.
  • Ceramic Tube with Filling: Increases breaking capacity for currents up to several kA.
  • Connection Caps: Made from copper alloy, treated for better contact and corrosion protection.
Characteristics
  • FF (Super Fast): For semiconductor protection.
  • gRL (Super Fast): Full-range protection for semiconductors.
  • gPV: For photovoltaic energy systems.
  • F (Fast): Protects against high overload and short-circuit currents.
  • M (Medium Time-Lag): Suitable for low operating voltages with low voltage drop.
  • T (Time-Lag): For high and slowly decaying inrush currents.
  • TT (Super Time-Lag): For very high and longer-lasting inrush currents.
Specifications and Standards
The document outlines the application of the IEC 60127 standard for fuse-links, with the German equivalent being VDE 0820. In North America, UL 248 is the reference standard for miniature fuses.
Fuse Construction
  • Filled Glass Tube: Can switch off prospective currents up to 1,000 A using quartz sand and reinforced glass.
  • Filled Ceramic Tube: Increases breaking capacity to several kA with ceramic tubes filled with quartz sand.
  • Terminal Caps: Made from copper alloy with special plating for better contact and corrosion protection.
Applications
  • Rated Currents: Different definitions exist between IEC 60127 and UL 248-14.
  • Low Voltage Operation: Fuse-links can operate below rated voltage, but voltage drop must be considered.
  • Ambient Temperature: Fuse-links are designed for 23°C; installation conditions can affect rated current.
  • Pulse Loads: Must be considered when assigning a fuse-link.
  • Semiconductor Protection: I²t value of the fuse-link is matched to the component's energy pulse.
  • Fuse-Holder Power Acceptance: Must not be exceeded by the fuse-link's power dissipation.
Safety and Quality
SIBA ensures quality through a documented quality management system based on DIN EN ISO 9001 and an environmental management system according to DIN EN ISO 14001.
Selection Diagram
A selection diagram is provided to guide the choice of miniature fuse-links based on technical requirements and operating conditions.
Specifications
  • Rated Current: Fuse-links with rated currents ranging from 32 mA to 20 A.
  • Rated Breaking Capacity: Varies, with some fuses rated at 35 A @ AC 250 V and others at 1500 A @ AC 250 V.
  • Voltage Drop: Values provided for each fuse type.
  • Power Dissipation: Values given at 1.5 times the rated current (In).
  • Fusing Time Limits: Minimum and maximum fusing times at different multiples of the rated current.
Construction
  • Materials: Fuse-links constructed using glass or ceramic tubes, with brass, nickel-plated end caps.
  • Transparency: Some fuses are transparent for visual inspection.
Approvals
Various fuses have approvals from organizations such as Semko, VDE, BEAB, and UL.
Time-Current Characteristics
Graphs and tables illustrate the time-current characteristics for different fuse types.
Additional Information
  • Non-standard Ratings: Some fuses are available in non-standard ratings.
  • Packaging: Available in different packaging options, including industrial packs and color-coded versions.
Fuse Holders
  • Types and Dimensions: Multiple types of fuse holders with specific dimensions and features.
  • Rated Voltage and Current: Support rated voltages of up to 250 V AC and 300 V DC.
  • Material: Made from tinned brass.
  • Mounting Options: Include PCB mounting, front-panel mounting, and in-line configurations.
  • Connections: Typically solderable, with some offering reflow solderable or quick-connect options.
  • Approvals: Many are VDE and UL recognized.
Key Features
  • Dielectric Strength: Most have a dielectric strength of 3 kV.
  • Protection Standards: Typically IP 40, with a shocksafe category of PC2.
  • Locking Mechanisms: Various mechanisms like screw caps and bayonet caps.
Recommendations
  • Ensure compatibility with specific fuse-link dimensions and electrical requirements.
  • Consider mounting and connection options that best suit the application environment.
  • Verify approval standards for compliance with regional safety regulations.
See more

Catalog excerpts

Miniature Fuses-1

Geräteschutzsicherungen Miniature Fuses Sie profitieren. Mit Sicherheit. Our Protection. Your Benefit.

 Open the catalog to page 1
Miniature Fuses-2

Umfassender Schutz vor zu großen Strömen – von der SMD-Sicherung bis zur Hochspannungstechnik Klassische zylindrische Sicherungen mit oder ohne Farbkennzeichnung nach unterschiedlichsten Normen, Kleinst-Sicherungseinsätze, SMDTechnologie, Sonderbauformen – auch der vorliegende neue Katalog zeigt wieder das ganze Spektrum des SIBA-Geräteschutzprogramms. Unsere Sicherungen schützen in vielen Bereichen vor zu hohen Strömen: Ob IT oder Telekommunikation, Haushaltsgeräte oder Industrieanwendungen. SIBA-Sicherungs-Know-how reicht aber weit über den Geräteschutz hinaus. Seit über 70 Jahren fertigen...

 Open the catalog to page 2
Miniature Fuses-3

Allgemeine Informationen / General Information Inhalt / Contents Allgemeine Informationen / General Information Produktübersicht / Product range Technische Erläuterungen / Technical notes Auswahldiagramm / Selection diagram Kleinstsicherungen / Sub-miniature Fuses Chip 0402, 0603, 0805, 120618 2,6 x 6,1 mm (SMD) 22 flink / quick acting träge / time-lag 4,5 x 8 mm (SMD)24 träge / time-lag flink / quick acting 4,5 x 16 mm (SMD)27 träge / time-lag superträge / very time-lag 8,4 x 7,6 mm31 flink / quick acting mittelträge / medium time-lag träge / time-lag G-Sicherungseinsätze / Fuse-Links 5 x 20...

 Open the catalog to page 3
Miniature Fuses-4

Allgemeine Informationen / General Information 4 © 2018-06 SIBA GmbH • www.siba.de • [email protected] Änderungen vorbehal

 Open the catalog to page 4
Miniature Fuses-5

Allgemeine Informationen / General Information Allgemeine Informationen / General Information Technische Erläuterungen (Begriffe, Normen, Basisdiagramme, Sicherungs-Charakteristiken u.a.), Hilfen zur Auswahl von Sicherungen Technical Notes (Terms, standards, basic diagrams, characteristics, … ), Selection guides © 2018-06 SIBA GmbH • www.siba.de • info@s

 Open the catalog to page 5
Miniature Fuses-6

Allgemeine Informationen / General Information Produktübersicht / Product range G-Sicherungseinsätze Fuse-Links Type G-Sicherungshalter Fuse-Holders Bem. spannung Rated Voltage 32 V 32 V 32 V 63 V 65 / 125 V 125 V 250 V 250 V 250 V 250 V 250 V 250 V 250 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V Charak teristik Charac teristic FF FF FF FF F T T T T T T F TT F F F F M M T T T T Bem.-Ausschalt vermögen Rated Breaking Capacity 50 A DC 50 A DC 50 A DC 50 A DC 50 A AC / DC 50 A AC / DC 100 A AC 100 A AC 1500 A AC/DC 1500 A AC/DC 1500 A DC/AC 100 A AC 35 A AC (35 A / 10 x lrat) AC...

 Open the catalog to page 6
Miniature Fuses-7

Allgemeine Informationen / General Information u G-Sicherungseinsätze Fuse-Links Type ¢ = nicht RoHS konform G-Sicherungshalter Fuse-Holders Abmessungen Charak teristik Charac teristic FF FF M Kennm. M Kennm. M Kennm. M Kennm. gPV gRL F F FF aR (FF) aR (FF) aR (FF) F Bem.-Ausschalt vermögen Rated Breaking Capacity Bem.Bem.spannung strom Rated Rated Voltage Current 250 V AC 6,3 A 250 V AC 6,3 A 250 V AC 6,3 A 250 V AC 6,3 A 250 V AC 20 250 V AC 6,3 A 250 V AC 6,3 A 250 V AC 10 A 500 V AC 6,3 A 42 V AC 6,3 A 42 V AC 6,3 A 250 V AC 6,3 A+10 A 500 V AC 6,3 A 500 V AC 6,3 A 500 V AC 6,3 A 500 V AC...

 Open the catalog to page 7
Miniature Fuses-8

Allgemeine Informationen / General Information Technische Erläuterungen / Technical Notes 1 Einleitung Geräteschutzsicherungen (G-Sicherungen) sind selbsttätig arbeitende Schaltorgane und schützen elektrische Anlagen, Geräte und Baugruppen vor unzulässig hohen Strombelastungen. Die Anwendung ist vielfältig. Geräteschutzsicherungen werden in der Unterhaltungselektronik zur Absicherung von Netzteilen und Leistungsendstufen verwendet. Für industrielle Anwendungen werden G-Sicherungen häufig als Primärsicherung eingesetzt, wo sie im Fehlerfall die defekte Baugruppe von der Spannungsversorgung trennen,...

 Open the catalog to page 8
Miniature Fuses-9

Allgemeine Informationen / General Information 3 Begriffe G-Sicherungen bestehen aus dem Sicherungseinsatz und dem Sicherungshalter. Der Sicherungseinsatz enthält den Schmelzleiter und muss nach dessen Schmelzen durch einen neuen Sicherungseinsatz ersetzt werden. Der Schmelzleiter kann unter vorgegebenen Bedingungen den Bemessungsstrom dauerhaft führen. Bei Überschreitung des Bemessungsstroms, oberhalb eines durch die Normen vorgegebenen Wertes schmilzt er, und es kommt zu einer Unterbrechung des Stromkreises. Die Dauer des Schmelz vorgangs ist in den entsprechenden Normen vorgegeben. Der Sicherungseinsatz...

 Open the catalog to page 9
Miniature Fuses-10

Allgemeine Informationen / General Information 3.3 Bemessungsausschaltvermögen I1 bei Urat Das Bemessungsausschaltvermögen kennzeichnet den maximalen Strom I1, den der Sicherungseinsatz bei Bemessungsspannung ordnungsgemäß abschalten kann. In manchen Anwendungsfällen kann es erforderlich sein, den zu erwartenden Kurzschlussstrom durch zusätzliche Impedanzen im Stromkreis zu verringern. I1 ≥ Ip 3.4 Spannungsfall ∆U Der Spannungsfall wird bei Betrieb des Sicherungseinsatzes mit seinem Bemessungsstrom und bei einer Umgebungstemperatur von 23 °C ermittelt. 3.5 Schmelzintegral I²tS Das Schmelzintegral...

 Open the catalog to page 10
Miniature Fuses-11

Allgemeine Informationen / General Information 4.3 Das Glasrohr mit Füllung Durch die Kombination einer Quarzsandfüllung als Löschmittel und die Verstärkung des Glasrohrs können prospektive Ströme bis zu 1000 A bei Bemessungsspannung ausgeschaltet werden. 4.4 Das Keramikrohr mit Füllung Eine weitere Steigerung des Bemessungsausschaltvermögens bis zu einem prospektiven Strom von einigen kA wird durch die Verwendung von Keramik ohren mit Quarzsandfüllung erzielt. r 4.5 Die Anschlusskappen Als Werkstoff für Anschlusskappen wird üblicherweise eine Kupferlegierung verwendet. Zur besseren elektrischen...

 Open the catalog to page 11
Miniature Fuses-12

Allgemeine Informationen / General Information In den nordamerikanischen Ländern ist die Bezugsnorm für Geräteschutzsicherungen UL 248. Besondere Vorsicht ist geboten bei der Konvertierung der Bemessungsströme von IEC 60127 zu denen nach UL 248 (siehe Bild 1). In the North American countries, the reference standard for m iniature fuses is UL 248. Special care is required in converting the rated currents of IEC 60127 into those according to UL 248 (see figure 1). 7.1 Unterschiedliche Definition der Bemessungsströme in den internationalen Normen 7.1 Different definitions of the Rated Currents in...

 Open the catalog to page 12

Archived catalogs

  1. Miniature Fuses

    92  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.