Siargo Product Datasheet Model: MFC2600 Mass Flow Controllers for Gases Model MFC2600 The products are designed for general-purpose, non-corrosive gas-flow control applications, with full-scale mass flow rates from 50 sccm to 20 SLPM. It features high accuracy and fast control time with a down-port configuration for manifold installation. Both analog and RS485 Modbus interfaces are offered. Other interfaces can also be requested. Electrical interface Bio-reactors Carrier gas Thin film deposition Gas mixing Fermentation Fuel efficiency Leakage testers Packaging process Air quality Purging and venting Anesthesia gas Controller body Installation screw Electrical interface description Installation screw Flow outlet Flow direction Flow inlet 4677 Old Ironsides Drive, Suite 310, Santa Clara, CA 95054 +1 (408) 969.0368 info@siargo
Open the catalog to page 1> Thin film deposition 4677 Old Ironsides Drive, Suite 310, Santa Clara, CA 95054 +1 (408) 969.0368 [email protected] www.Siargo.com
Open the catalog to page 2Siargo Product Datasheet Model: MFC2600 Full-scale range ± 1.0% r.d. (20 ~ 100% of full scale) ±0.2% FS (<20% of full scale) ± 0.3% r.d. (20 ~ 100% of full scale) ±0.06% FS (<20% of full scale) Turn-down ratio Control pressure range Power supply Output signal > Thin film deposition Max null shift (analog) Control valve Electrical connector Mechanical connection Storage temperature Reference conditions Fluid compatibility 0 °C, 101.325 kPa, air Non-corrosive EN61000-2; -3; -4 RoHS, REACH *All specifications listed in the following table, unless otherwise noted, apply to calibration conditions...
Open the catalog to page 3> Thin film deposition for other gases, please contact the manufacturer. ) Default setpoint source (o - analog; 1 - digital) Setpoint source and output - Digital (B - RS485) and Analog (A - 4-20 mA; V - 0 ~ 5 Vdc). Selectable: BA or BV Maximum full-scale flow rate. The setpoint source and output are 4-20 mA and RS485, respectively, with 4-20 mA as the default setpoint source. The setpoint source and output are 4-20 mA and RS485, respectively, with RS485 as the default setpoint source. The setpoint source and output are 1-5 Vdc and RS485, respectively, with 1-5 Vdc as the default setpoint source....
Open the catalog to page 42 Pages
2 Pages
2 Pages
5 Pages
2 Pages
2 Pages
3 Pages
2 Pages
8 Pages
5 Pages
4 Pages
2 Pages
2 Pages
98 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
3 Pages
2 Pages
3 Pages
4 Pages
4 Pages
2 Pages
3 Pages
2 Pages